ARTESYN LPS360-M SERIES 360 Watt AC-DC Power Supply Advanced Energys Artesyn LPS360-M series of open-frame AT A GLANCE AC-DC power supplies comprises five single output models, offering voltages of 12 V, 15 V, 24 V, 36 V or 48 V. Total Power: Each power supply also provides 12 V fan and 5 V standby 200 to 360 W outputs. All four models feature ITE and medical safety approvals and accept a universal input of 90264 Vac or Input Voltage: 120300 Vdc. Comprehensive overcurrent, overvoltage 90 to 264 Vac 120 to 300 Vdc and overtemperature protection is provided as standard. Additional facilities include main output remote sense, Outputs: Power fail signal and I2C for basic monitoring and control. Single LPS360-M power supplies have a full load efficiency of up to 92%. Depending on operating conditions, they provide up to 240 watts of output power with free air convection cooling and up to 360 watts with 400 LFM of forced air. Less than 1U high, the power supplies are ideal for light industrial systems as well as patient contact Type BF medical applications. Overload protection SPECIAL FEATURES SAFETY Thermal overload protection Medical and ITE safeties TUV 62368, 60601-1 12 V fan output Active power factor correction UL 62368, 60601-1 LPX200 enclosure kit available 3 x 5 footprint cULus 62368, 60601-1 5 V Standby output Less than 1U high CB Certificate & report Remote Inhibit EN61000-3-2 compliant CE Mark (LVD & EMC) PMBus commands Remote sense CCC Approval RoHS compliant 2 Power fail ** LPS360-M tested according to the Digital I C interface medical standard IEC 60601-1-2 4th Adjustable main output Designed to meet Class I and Class II Edition. Level B Conducted EMI - Class I or Dual AC fuses Class II inputs Suitable for BF Type applications Overvoltage protection 2021 Advanced Energy Industries, Inc.LPS360-M ELECTRICAL SPECIFICATIONS Input Input ra nge 90 - 264 Vac 120 - 300 Vdc Frequency 47 - 63 Hz Inrush current 50 A max., cold start 25 C Efficiency Up to 93% at full load EMI/RFI FCC Class B conducted CISPR22 Class B conducted EN55022 Class B conducted VDE0878PT3 Class B conducted Power factor 0.99 typical Safety ground leakage current 150 A 132 Vac, 60 Hz for class I, 300 A 264 Vac, 60 Hz for class II Output Maximum power 200 - 240 W (see de-rating) for convection, 360 W with 400 LFM of forced air Adjustment range 12 V and 24 V models, -0%, +15% 15 V and 48 V models, -5%, +10% 36 V model, -15%, +0% Standby output 5 V 1A convection, 2 A with forced air Fan output 12 V 0.5 A convection, 1 A forced air Hold-up time 20 ms 240 W, 220 Vac input 12 ms 360 W Overload protection Short circuit protection on all outputs. Case overload protected 110 - 160% above rating Overvoltage protection 30 - 50% above nominal output Logical Control Power failure Open collector logic signal goes high 100 - 500 msec after main output it goes low at least 6 msec before loss of regulation Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. ENVIRONMENTAL SPECIFICATIONS Operating temperature -20 C to 50 C ambient, derate each output as 2.5% per degree from 50 C to 70 C -40 C startup if Standby output 1A (any valid load on main output) -30 C startup if Standby output > 1A (any valid load on main output) Storage temperature -40 C to +85 C Electromagnetic susceptibility Designed to meet EN61000-4 -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating non-condensing 10% to 95% RH Vibration IEC68-2-6 to the levels of IEC721-3-2 MTBF calculated >2 million hours at full load and 25 C ambient conditions. 230 Vac input, Bellcore 2 advancedenergy.com