ARTESYN LPS40 SERIES 40 Watts Advanced Energys Artesyn LPS40-M series of open-frame DATA SHEET comprises four single output models, offering voltages of 5 V, 12 V, 15 V or 24 V. Each model accepts a universal input of Total Power: 85264 Vac or 120300 Vdc. All four feature medical safety 25 - 40 Watts approvals, with a very low safety ground leakage current of less than 75 microamps. These compact switch-mode Input Voltage: power supplies feature output overvoltage and short- 85 - 264 Vac 120 - 300 Vdc circuit protection, as well as remote sense. They provide 40 watts of output power with free air convection cooling of Outputs: and 55 watts with 30 CFM of forced air. Less than 1U high, Single LPS40-M power supplies are designed for medical, test and measurement, single-board computers, telecommunications and networking applications. SPECIAL FEATURES SAFETY Universal input cUL 62368 E132002 3 x 5 footprint CSA CSA 22.2-234 Level 3 Less than 1U high LR53982C Remote sense NEMKO EN 62368/EMKO-TUE Built-in EMI filter P94100375 (74-sec) 203 Low output ripple CB Certificate and report Adjustable output 1119, 1125, 1126, 1127 Overvoltage protection CE Mark (LVD) Overload protection 110 KHz switching frequency LPX40 enclosure kit available RoHS compliant 2020 Advanced Energy Industries, Inc.LPS40 ELECTRICAL SPECIFICATIONS Input Input range 85 - 264 Vac 120 - 300 Vdc Frequency 47 - 440 Hz Inrush current < 18 A peak 115 Vac < 36 A peak 230 Vac, cold start 25 C Input current 1 A max. (RMS) 115 Vac Efficiency 70% typical at full load EMI filter FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 class B conducted Safety ground leakage current < 0.5 mA 50/60 Hz, 264 Vac input Output Maximum power 40 W for convection 55 W with 30CFM forced air Adjustment range -5, +10% minimum Hold-up time 20 ms 40 W load, 115 VAC nominal line Overload protection Short circuit protection on all outputs Case overload protected 110-145% above peak rating Overvoltage protection 5 V output 5.7 to 6.7 Vdc. Other outputs 10% to 25% above nominal output Remote sense Compensates for 0.5 V lead drop minimum Will operate without remote sense connected Reverse connection protected ENVIRONMENTAL SPECIFICATIONS Operating temperature 0 to 50 C ambient. Derate each output 2.5% per degree from 50 to 70 C, -20 C start up. Storage temperature -40 C to +85 C Temperature coefficient 0.4% per C Electromagnetic susceptibility Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating non-condensing 5% to 95% RH Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational MTBF demonstrated > 550,000 hours at full load and 25 C ambient conditions 2 advancedenergy.com