Embedded Power for Business-Critical Continuity Rev. 05.27.08 LPS60 Series 1 of 3 LPS60 Series 60 Watts Total Power: 60 - 80 Watts Input Voltage: 85 - 264 Vac 120 - 300Vdc of Outputs: Single Electrical Specifications Input Special Features Input ra nge: 85 - 264 Vac (wide range) Universal input 120 - 300 Vdc 3 x 5 footprint Frequency: 47-440 Hz Remote sense Inrush current: <18A peak 115 Vac, <36 A peak 230 Vac, Built in EMI filter cold start 25 C Low output ripple Input current: 1.5 A max. (RMS) 115 Vac Adjustable output voltage Overload protection Efficiency: 70% typical at full load 110 KHz switching frequency EMI filter: FCC Class B conducted CISPR22 Class B conducted EN55022 LPX60 enclosure kit available Class B conducted VDE0878PT3 Class B conducted Safety ground leakage <0.5 mA 50/60 Hz 264 Vac input current: Output Maximum power: 60 W for convection 80 W with 30 CFM forced air Adjustment range -5, +10% minimum Hold-up time 20 ms 60 W load, 115 Vac nominal line Overload protection Short circuit protection on all outputs. Case overload protected 110-145% above peak rating Overvoltage protection 5 V output 5.7 - 6.7 Vdc. Other outputs 10% to 25% Safety above nominal output VDE 0805/EN60950 (IEC950) Remote sense Compensates for 0.5 V lead drop min. Will operate without 11774-3336-1255 remote sense connected. Reverse connection protected. (LC 86665) UL UL1950 E132002 CSA CSA 22.2-234 Level 3 LR53982C NEMKO EN 60950/EMKO-TUE P95100123 (74-sec) 203 CB Certificate and report 1521, 1522, 1523, 1524 CE Mark (LVD)Rev. 05.27.08 LPS60 Series 2 of 3 Environmental Specifications Operating temperature: Power Derating Curve 0 to 50 C ambient derate each output as 2.5% per degree from 50 to 70 C, -20 C startup 80W Storage temperature: -40C to +85 C 30 CFM Forced Air Cooling Electromagnetic designed to meet IEC801, -2, -3, -4, -5, -6, Level 3 60W Output susceptibility: Power (Watts) Humidity: Operating non-condensing 5% to 95% RH 40W 40W Natural Three orthogonal axes, sweep at 1 cot/min, Convection 30W Vibration: 5 min. dwell at four major resonances 0.75 G peak Cooling 20W 5 Hz to 500 Hz, operational Temperature coefficient 0.04% per C 0W 0C 10C 20C 30C 40C 50C 60C 70C >550,000 hours at full load and 25 C ambient MTBF demonstrated conditions TA Ambient Temperature C Mechanical Drawing 0.22 M2 (5.6) Remote Sense GND + SK201 Connector M1 Voltage Adj. Pot 3.00 (76.2) SK 2 1 2 2.55 3 (64.8) 4 SK 1 5 1 N 6 3 L 0.15 (4) 4.56 0.22 DIA (4 places) (115.8) (5.6) 5.00 (127) 1.69 (42.9) 0.12 (3)