ARTESYN LPT100-M SERiES 130 Watts Advanced Energy s Artesyn LPT100-M series of triple output Data Sheet open-frame AC-DC power supplies features ITE and medical safety approvals. There is a choice of four models, covering Total Power: output voltages from 3.3 V to 24 V. The power supplies have 130 Watts a typical full load power conversion efficiency of 82% and input Voltage: with a height of only 1.28 inches offer a power density in excess of 12 watts per cubic inch. LPT100-M power supplies 90 - 264 Vac are primarily designed for use in information technology of Outputs: equipment (ITE) and light industrial systems, as well as for Triple equipment intended for non-patient contact and non-patient critical use in low power medical, dental and laboratory applications. Thermal overload protection SPEciAL FEATuRES LPX100 enclosure kit available Medical and ITE safeties RoHS compliant Active power factor correction SAFETY 2 x 4 footprint Less than 1U high TUV 62368, 60601-1 EN61000-3-2 compliant UL 62368, 60601-1 Remote sense CSA 62368, 60601-1 Power fail NEMKO 62368, 60601-1 Adjustable main output AUSTEL 62368, 60601-1 Built-in Class B EMI filter CB Certificate & report Overvoltage protection CE Mark (LVD) Overload protection 2020 Advanced Energy Industries, Inc.LPT100-M ELEc TRic AL SPEciFic ATiONS input Input ra nge 90 - 264 Vac 127 - 300 Vdc Frequency 47 - 63 Hz Inrush current 50 A max., cold start 25 C Efficiency 82% typical at full load EMI/RFI FCC Class B conducted CISPR22 Class B conducted EN55022 Class B conducted VDE0878PT3 Class B conducted Safety ground leakage current 275 A 50/60 Hz, 264 Vac input Output Maximum power 130 W with 200 LFM forced air Adjustment range All outputs adjustable: -20%, +10%, except for +24V output on LPT104-M which will be -10%, +20% and 3.3 V output on the LPT101-M +10%, -15% Hold-up time 10 ms 130 W load, 120 Vac input Overload protection Short circuit protection on all outputs. Case overload protected 110 - 160% above rating for V1 & V2, 150 - 250% for V3 Overvoltage protection 15 - 35% above nominal output Logical control Power failure Active LowTTL logic signal goes high 100 - 500 msec after main output it goes low at least 6 msec before loss of regulation Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. ENViRONMENTAL SPEciFic ATiONS 0 C to 50 C ambient derate each output as 2.5% per degree from 50 C to 70 C. -20 C start up Operating temperature -40 C to +85 C Storage temperature Designed to meet EN61000-4 -2, -3, -4, -5, -6, -8, -11 Level 3 Electromagnetic susceptibility: Operating non-condensing 10% to 90% RH, non-operating, non-condensing 10% - 95% Humidity IEC68-2-6 to the levels of IEC721-3-2 Vibration 583,000 hours at full load and 25 C ambient conditions. 230 Vac input, Bellcore MTBF calculated 2 advancedenergy.com