POWER LPT60-M Series Data Sheet 60 Watts Total Power: 60 - 80 Watts Input Voltage: 85 - 264 Vac 120 - 300 Vdc of Outputs: Triple SPECIAL FEATURES Medical safety approvals Universal input 3 x 5 footprint Remote sense on main output Built-in EMI filter Low output ripple Electrical Specifications Adjustable 5V output Input Overvoltage protection Overload protection Input range 85 - 264 Vac 110 KHz switching frequency 120 - 300 Vdc LPX60 enclosure kit available Frequency 47 - 440 Hz RoHS compliant Inrush current <18 A peak 115 Vac <36 A peak 230 Vac, cold start 25 C SAFETY Input current 1.5A max. (RMS) 115VAC VDE 0750/EN60601-1 (IEC601) Efficiency 70% typical at full load 21310-3336-0015 EMI FCC Class A conducted CISPR 22 Class A conducted EN55022 Class UL UL2601 A conducted VDE 0878 PT3 Class A conducted E182560 Safety ground <75 A max. 50/60 Hz, 264 Vac input CSA CSA 22.2 No. 601.1 leakage current LR109492 Output CE Mark (LVD) Maximum power 60 W for convection 80 W with 30CFW forced air Cross regulation 2% on output 1 5% on outputs 2, 3 Adjustment range -5, +10% minimum Hold-up time 20 ms 60 W load, 115 Vac nominal line Overload protection Short circuit protection on all outputs. Case overload protected 110% to 145% above peak rating Overvoltage protection 5.7 to 6.7 Vdc on the main output Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.LPT60-M Series Data Sheet Environmental Specifications Operating temperature 0 C to 50 C ambient derate each output at 2.5% per degree from 50 C to 70 C, -20 C startup Electromagnetic susceptibility Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating non-condensing 5% to 95% Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 5G peak 5 Hz to Vibration 500 Hz, operational Storage temperature -40 C to 85 C Temperature coefficient .04% per C MTBF demonstrated >550,000 hours at full load and 25 C ambient conditions Ordering Information Ripple Output Minimum Maximum Load with Maximum Load with 1 2 Model Number Peak Load Regulation 3 Voltage Load Convection Cooling 30CFM Forced Air P/P (PARD) +5 V 0.7 A 7 A 8 A 10 A 2% 50 mV LPT62-M +12 V 0.3 A 3 A 3.5 A 6 A 5% 120 mV -12 V 0 A 0.7 A 1 A 1.5 A 5% 120 mV +5 V 0.7 A 7 A 8 A 10 A 2% 50 mV LPT63-M +15 V 0.3 A 2.8 A 3.3 A 4 A 5% 150 mV -15 V 0 A 0.7 A 1 A 1.5 A 5% 150 mV 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10F in parallel with a 0.1F capacitor at rated line voltage and load ranges. 4. Minimum Loads are required. 5. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is not intended for sale to End Users. Power Derating Curve 80W 30 CFM Forced Air Cooling 60W Output Power (Watts) 40W 40W Natural Convection 30W Cooling 20W 0W 0C 10C 20C 30C 40C 50C 60C 70C TA Ambient Temperature C