ARTESYN LPT60-M SERiES 60 Watts Advanced Energy s Artesyn LPT60-M series of open-frame Data Sheet AC-DC power supplies comprises two triple output models covering standard voltages from -15 V to 15 V. Both models Total Power: accept a universal input of 85264 Vac or 120300 Vdc 60 - 80 Watts and feature medical safety approvals, with a very low safety input Voltage: ground leakage current of less than 75 microamps. These compact switch-mode power supplies feature main output 85 - 264 Vac 120 - 300 Vdc overvoltage protection and remote sense, with short-circuit protection on all outputs. LPT60-M series power supplies of Outputs: provide 60 watts of output power with free air convection Triple cooling and 80 watts with 30 CFM of forced air. They are suitable for a wide variety of of medical, laboratory and dental applications, as well as low power industrial applications. SPEciAL FEATuRES SAFETY Medical safety approvals VDE 0750/EN60601-1 (IEC601) 21310-3336-0015 Universal input UL UL2601 3 x 5 footprint E182560 Remote sense on main output CSA CSA 22.2 No. 601.1 Built-in EMI filter LR109492 Low output ripple CE Mark (LVD) Adjustable 5V output Overvoltage protection Overload protection 110 KHz switching frequency LPX60 enclosure kit available RoHS compliant 2020 Advanced Energy Industries, Inc.LPT60-M ELEc TRic AL SPEciFic ATiONS input Input range 85 - 264 Vac 120 - 300 Vdc Frequency 47 - 440 Hz Inrush current <18 A peak 115 Vac <36 A peak 230 Vac, cold start 25 C Input current 1.5A max. (RMS) 115VAC Efficiency 70% typical at full load EMI FCC Class A conducted CISPR 22 Class A conducted EN55022 Class A conducted VDE 0878 PT3 Class A conducted Safety ground leakage current <75 A max. 50/60 Hz, 264 Vac input Output Maximum power 60 W for convection 80 W with 30CFW forced air Cross regulation 2% on output 1 5% on outputs 2, 3 Adjustment range -5, +10% minimum Hold-up time 20 ms 60 W load, 115 Vac nominal line Overload protection Short circuit protection on all outputs. Case overload protected 110% to 145% above peak rating Overvoltage protection 5.7 to 6.7 Vdc on the main output Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. ENViRONMENTAL SPEciFic ATiONS 0 C to 50 C ambient derate each output at 2.5% per degree from 50 C to 70 C, -20 C startup Operating temperature Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Electromagnetic susceptibility Operating non-condensing 5% to 95% Humidity Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 5G peak 5 Hz to 500 Hz, Vibration operational -40 C to 85 C Storage temperature .04% per C Temperature coefficient MTBF demonstrated >550,000 hours at full load and 25 C ambient conditions 2 advancedenergy.com