ARTESYN LPT60 SERiES 60 Watts Advanced Energy s Artesyn LPT60 series of open-frame Data Sheet AC-DC power supplies comprises five triple output models covering standard voltages from -15 V to 24 V. Each model Total Power: accepts a universal input of 85264 Vac or 120300 Vdc. 60 - 80 Watts These compact switch-mode power supplies feature main input Voltage: output over-voltage protection and remote sense, with short- circuit protection on all outputs. LPT60 series power supplies 85 - 264 Vac 120 - 300 Vdc provide 60 watts of output power with free air convection cooling, and 80 watts with 30 CFM of forced air. They are of Outputs: suitable for a wide variety of low power industrial applications. Triple SPEciAL FEATuRES SAFETY Universal input UL: 62368 E132002 3 x 5 footprint cUL : 62368 Remote sense on main output LR53982C Built-in EMI filter NEMKO: EN 62368/EMKO-TUE Low output ripple P95100123 (74-sec) 203 Adjustable main output CB: Certificate and report Overvoltage protection 1518, 1519, 1520 Overload protection CE: Mark (LVD) 110 KHz switching frequency LPX60 enclosure kit available RoHS compliant 2020 Advanced Energy Industries, Inc.LPT60 ELEc TRic AL SPEciFic ATiONS input Input range 85 - 264 Vac 120 - 300 Vdc Frequency 47 - 440 Hz Inrush current <18 A peak 115 Vac <36 A peak 230 Vac, cold start 25 C Input current 1.5 A max. (RMS) 115 Vac Efficiency 70% typical at full load (60% for LPT61) EMI FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted Safety ground leakage current <0.5 mA 50/60 Hz, 264 Vac input Output Maximum power 60 W for convection (LPT61, 35 W) 80 W with 30CFW forced air (LPT61, 55 W) Cross regulation 2% on output 1 5% on outputs 2, 3 Adjustment range -5, +10% minimum Hold-up time 20 ms 40 W load, 115 Vac nominal line Overload protection Short circuit protection on all outputs. Case overload protected 110% to 145% above peak rating Overvoltage protection 5.7 to 6.7 Vdc on the main output LPT41: 3.6 to 4.6 Vdc Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. ENViRONmENTAL SPEciFic ATiONS 0 C to 50 C ambient derate each output at 2.5% per degree from 50 to 70 C, -20 C startup Operating temperature Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Electromagnetic susceptibility Operating non-condensing 5% to 95% Humidity Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5 Hz to 500 Hz, Vibration operational -40 C to 85 C Storage temperature .04% per C Temperature coefficient mTBF demonstrated >550,000 hours at full load and 25 C ambient conditions 2 advancedenergy.com