400-1200 Watts MP Series Special Features Current share on all outputs with ratings of 10 A or greater Remote sense on all outputs with ratings greater than 2 A Overload protection on all outputs Voltage adjustment on all outputs Margining on all single output modules Input OK signal and status indicator LED MP4 Global DC OK signal and status indicator LED Global and individual module inhibits/enable 2 year warranty Forced air cooling, field replaceable fan Isolated 5 V bias voltage Power factor correction EN61000-3-2 harmonic distortion compliance CISPR 22, EN55022 Curve B conducted / radiated EMI European CE Mark requirements Optional VME timing and system DC OK module Customer-provided air option Additional 200 W output high line (180-264 VAC) Low leakage option for medical applications MP6 EN61000 immunity standards Standard modification flexibility (consult factory) Low noise fan Fan fail signal Module enable Outputs down to 0.5V Environmental Operating temperature: -20C to 50C (start 0C) (derate each output linearly to 50% at 70C) (-20C to 40C max. with rear air option) Shock/Vibration: Mil-Hdbk 810E MP8 Humidity: 95% non-condensing Storage temperature: -40C to +85C Temperature coefficient: 0.02% per C Cooling: Internal DC fan or customer provided air (option) Safety UL UL1950 CSA CSA22.2 No. 234 Level 5 IEC IEC950, Class 1 MP1 VDE EN60950, BABT Compliance to EN 60950, BS 7002 CB Certificate and report CE Mark Technical Support: (888) 41ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662 136 Rev 2.17.06MP Series ASIA EUROPE AMERICAS Units 2111-2116, Level 21 Astec House, Waterfront Business Park 5810 Van Allen Way Tower1, Metroplaza Merry Hill, Dudley Carlsbad, CA 92008 West Midlands, DY5 1LX, UK 223, Hing Fong Road Telephone: 760-930-4600 Kwai Fong, New Territories Telephone: 44 (1384) 842-211 Facsimile: 760-930-0698 Facsimile: 44 (1384) 843-355 Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 Electrical Specs Input Output Input voltage 85-264 VAC Adjustment range 10% min. all outputs 1 120-350 VDC Margining 4-6% nom. Frequency 47-440 Hz Overall reg 0.4% or 20 mV max. Inrush current 40 A peak max. (soft start) (36 W modules 4% max.) Efficiency 70-80% typ. full case load Ripple RMS: 0.1% or 10 mV, whichever is greater Power factor 0.99 typ. meets EN61000-3-2 Pk-Pk: 1.0% or 50 mV, whichever is greater Bandwidth limited to 20 MHz Turn-on time AC on 1.5 sec typ., Inhibit / Enable 150 ms typ. Dynamic response <2% or 100 mV, with 25% load step. EMI filter standard CISPR 22 Recovery time To within 1% in <300 sec. EN55022 Level B Overcurrent protection Single, main of dual output module EMI filter 105-120% of rated output current. (low leakage option) CISPR 22 Aux output of dual output module 105-140% EN55022 Level A of rated output current. Leakage current standard 2.0 mA max. 240 VAC Triple output module internally protected Leakage current Short circuit protection Protected for continuous short circuit (low leakage option). 300 A max. 240 VAC Recovery is automatic upon removal of short. Radiated EMI CISPR 22 Overvoltage protection EN55022 Level B (measured at sense Holdover storage 20 ms minimum connection) Single output modules (independent of input VAC) 2-5.5 V 122-134% 6-60 V 110-120% AC OK >5 ms early warning min. Dual output module before outputs loose regulation 2-6 V 122-134% Full cycle ride thru (50 Hz) 8-28 V 110-120% Harmonic distortion Meets EN61000-3-2 Triple output module. Isolation Meets EN60950 No overvoltage protection provided. Recycle Global Inhibit/Enable TTL, Logic 1 and Logic 0 the AC input voltage to reset OVP circuit Input fuse (internal) MP4: 10 A Reverse voltage protection 100% of rated output current MP6: 15 A Thermal protection All outputs disabled when internal temp MP8: 20 A exceeds safe operating range. >5 ms warning MP1: 20 A (AC OK signal) before shutdown Warranty 2 years Remote sense Up to 0.5 V total drop (not available on triple output module) 2 Power Derating Curve Single wire parallel Current share to within 2% of total rated current 2 50 DC OK -2% to -8% of nominal for any monitored output 100 Minimum load Not required on single or triple output modules. 3 10% required on main of dual output modules 80 Normal Housekeeping bias voltage 5 VDC 1.0A mA max. present whenever AC Air Flow input is applied % 60 Module inhibit TTL, isolated, singles and dual Rated 50 Total (both outputs) only Case Switching frequency 250 kHz 40 Load Output/Output isolation >1 Megohm VME signal option board POR signal & quad external DC OK 20 Hold-up module (HUP) 1-slot module providing an additional 34mSec (60mSec total) hold-up 600W loading. 40 45 55 60 65 70 30 35 50 TA Ambient Temperature C Notes: 1. Single output modules only. 2. Single and main of dual output modules only. 3. Contact factory for optional preload if required. www.astecpower.com 137