MVP Series 400 - 1000 Watts SPECIAL FEATURES Current share on all outputs with ratings of 10 A or greater Remote sense on all outputs with ratings greater than 2 A Overload protection on all outputs Voltage adjustment on all outputs MP4-1E-1Q-1Q-LLE-00 .................................. 400 W total Margining on all single output modules Input-OK-signal and status indicator LED Global DC OK signal and status indicator LED Global and individual module inhibits/enable 1 year warranty Forced air cooling, field replaceable fan Isolated 5 V bias voltage Power factor correction IEC EN61000-3-2 harmonic distortion compliance CISPR 22, EN55022 Curve B conducted / radiated EMI European CE Mark requirements Optional VME timing and system DC OK module Low leakage option for medical applications Immunity - EN61000 -4, -2, -3, -4 & -5 Level 3 MP6-3E-1E-4LL-0M ........................................ 600 W total ENVIRONMENTAL Operating temperature: -20C to 50C (start 0C) (derate each output linearly to 50% at 70C) (-20C to 40C max. with rear air option) Shock/Vibration: Mil-Hdbk 810E Humidity: 95% non-condensing Storage temperature: -40C to +85C Temperature coefficient: 0.02% per C Cooling: Internal DC fan (Field replaceable) MP8-3E-1L-1L-4NN-00 .................................. 800 W total (P/N 73-688-0001) SAFETY UL UL1950 CSA CSA22.2 No. 234 Level 5 IEC IEC950, Class 1 VDE EN60950, BABT Compliance to EN 60950, BS 7002 CB Certificate and report CE Mark MP1-2Q-1D-1E-1L-1N-LLE-00 ...................... 1000 W total UK: +44 (0)1384 842211 France: +33 (0)1 4305 8680 Germany: +49 (0)6621 50570 Netherlands: +31 (0)24 372 3210MVP Series Astec Standard Power Germany Astec Standard Power Europe Astec France S.A.R.L. Astec Netherlands Astec House, Waterfront Business Park 424 La Closerie, Mont Dest Robert-Heil-Str. 8 Kerkenbos 10-125 M Merry Hill, Dudley 93194 Noisy le Grand 36251 Bad Hersfeld Nijmegen West Midlands. DY5 1LX France Germany The Netherlands E Telephone: +44 (0)1384 842211 Telephone: +33 (0)1 4305 8680 Telephone: +49 (0)6621 50570 Telephone: +31 (0)24 372 3210 Facsimile:+44 (0)1384 843355 Facsimile: +33 (0)1 4304 6033 Facsimile: +49 (0)6621 505720 Facsimile:+31 (0)24 372 3219 D I U Output ELECTRICAL SPECIFICATIONS Adjustment range ................... 10% min. all outputs M 1 Margining ............................... 4-6% nom. Input Overall reg.............................. 0.4% or 20 mV max. Input voltage .......................... 85-264 VAC P (36 W modules 4% max.) 120-350 VDC Ripple ..................................... RMS: 0.1% or 10 mV, O Frequency .............................. 47-440 Hz whichever is greater Inrush current ......................... 40 A peak max. W Pk-Pk: 1.0% or 50 mV, Efficiency ................................ 70-80% typ. full case load whichever is greater E Power factor ........................... 0.99 typ. meets EN61000-3-2 Bandwidth limited to 20 MHz Turn-on time ........................... AC on 1.5 sec typ., R Dynamic response ................. <2% or 100 mV, with 25% Inhibit / Enable 150 ms typ. load step. EMI filter standard .................. CISPR 22 Recovery time ........................ To within 1% in <300 sec. EN55022 Level B Overcurrent protection ........... Single, main of dual output EMI filter (low leakage option) .. CISPR 22 module 105-120% of rated EN55022 Level A output current. Leakage current standard ...... 2.0 mA max. 240 VAC Aux output of dual output Leakage current module 105-140% of rated (low leakage option)............. 300 A max. 240 VAC output current. Radiated EMI ......................... CISPR 22 Triple output module Internally EN55022 Level B protected Holdover storage.................... 20 ms minimum Short circuit protection ........... Protected for continuous short (independent of input VAC) circuit. Recovery is automatic AC OK .................................... >5 ms early warning min. before upon removal of short outputs loose regulation Overvoltage protection ........... Single output modules Full cycle ride thru (50 Hz) (measured at sense 2-5.5 V 122-134% Harmonic distortion ................ Meets EN61000-3-2 connection) 6-60 V 110-120% Isolation .................................. Meets EN60950 Dual output module Global Inhibit/Enable .............. TTL, Logic 1 and Logic 0 2-6 V 122-134% Input fuse (internal) ................ MP4: 10 A 8-28 V 110-120% MP6: 15 A Triple output module. MP8: 20 A No overvoltage protection MP1: 20 A provided. Recycle the AC input Warranty ................................. 1 year voltage to reset OVP circuit Reverse voltage protection ............................... 100% of rated output current Thermal protection ................. All outputs disabled when internal temp exceeds safe Power Derating Curve operating range. >5 ms warning 50 (AC OK signal) before shutdown 100 Remote sense ........................ Up to 0.5 V total drop Single wire parallel ................. Current share to within 2% of 2 80 total rated current Normal DC OK .................................... -2% to -8% of nominal for any Air Flow 2 % monitored output 60 Rated Minimum load ......................... Not required on single or triple 50 Total output modules. 10% required Case 40 Load on main of dual output 3 modules Housekeeping 20 Bias voltage ............................ 5 VDC 1A max. present whenever AC input is applied 40 45 55 60 65 70 30 35 50 Module inhibit ......................... TTL, isolated, singles and dual TA Ambient Temperature C (both outputs) only Switching frequency ............... 250 kHz Output/Output isolation .......... >1 Megohm VME signal option board ........ POR signal Notes: 1 Single output modules only. 2 Single and main of dual output modules only. 3 Contact factory for optional preload if required. REV 25.10.00 www.astec.com