process yellow 116 1375 1797 375 3405 313 2985 240 Embedded Power for Business-Critical Continuity 242 2607 Rev. 06.18.10 139 NFS110-M Series 1 of 5 652 NFS110 Medical Series Single and quad output Total Power: 80 - 110 W Input Voltage: 90 - 253 Vac 127 - 357 Vdc of Outputs: Single, quad Electrical Specifications Output Voltage adjustability: +5.1 V o/p on multis 3.0% Special Features 5.1 V single output 3.0% 7.0 x 4.25 x 1.8 inch package 12 V single output 12 - 14 V Medical, dental and 15 V single output 15 - 18 V laboratory applications 24 V single output 24 - 30 V Overvoltage and short circuit Line regulation: LL to HL, FL 0.1% max. protection All outputs on all units 110 W with 20 CFM Overshoot/undershoot: UL, VDE and CSA safety At turn-on no lead 0% approvals Temperature coefficient: All outputs 0.02% / C EN60601-1 and UL2601 Overvoltage protection: Multi o/p 5.1 V only 6.25 V 0.75 V medical approvals 5.1 V single 6.25 V 0.75 V Available RoHS compliant 12 V single 15.75 V 1.0 V 2 year warranty 15 V single 22 V 1.5 V 24 V single 33 V 2.5 V Output power limit: Primary power Pin max. 160 W limited Pout min. 110 W Burst mode operation Short circuit protection: Input Safety Input voltage range: 90 - 253 Vac VDE0805/EN60601-1/ 127 - 357 Vdc IEC60601/IEC1010 Input frequency range: 47 - 440 Hz File No. 10401-3336-1049 Licence No. 2874 Input surge current: 110 Vac. 50 Hz 17 A UL60601-1 File No. E182560 230 Vac. 50 Hz 25 A CSA C22.2 No. 125 Safety ground leakage current: 132 Vac 50 A File No. LR41062C 264 Vac 100 A All specifications are typical at nominal input, full load at 25 C unless otherwise statedprocess yellow 116 1375 1797 375 3405 313 2985 240 242 Embedded Power for Business-Critical Continuity 2607 Rev. 06.18.10 139 NFS110-M Series 2 of 5 652 EMC Characteristics Conducted emissions: EN55022, FCC part 15 Level A Radiated emissions: EN55022, FCC part 15 Level A ESD air: EN61000-4-2, level 3 Perf. criteria 1 ESD contact: EN61000-4-2, level 4 Perf. criteria 1 Surge: EN61000-4-3, level 3 Perf. criteria 1 Fast transients: EN61000-4-4, level 3 Perf. criteria 1 Radiated immunity: EN61000-4-5, level 3 Perf. criteria 2 EN61000-4-6, level 3 Perf. criteria 2 Conducted immunity: General Specifications Hold-up time: 110 Vac 80 W 35 ms 110 Vac 110 W 17 ms 230 Vac 80 W 140 ms 230 Vac 110 W 100 ms Efficiency: Multiple outputs 70% typical +5.1 V single 70% typical 12 V and 15 V singles 72% typical 24 V single 75% typical Isolation voltage: Input/output 4000 Vac Input/chassis 1500 Vac Approvals and standards: VDE0750, IEC60601, IEC1010, UL60601, (see note 12) CSA C22.2 No. 125 Weight: Singles 550 g (19.4 oz) Multiple outputs 600 g (21.2 oz) MTBF ( 25 C) MIL-HDBK-217E 125,000 hours min. Environmental Specifications Thermal performance: Operating, see curve 0 C to +70 C (See notes 9, 10) Non-operating -40 C to +85 C 0 C to 50 C amb. convection cooled 80 W +50 C to +70 C, Derate 2 W/C amb. convection cooled 0 C to +50 C, 20 CFM forced air 110 W +50 C to +70 C, 20CFM forced air Derate 2.75 W/C Peak, 0 C to +50 C, max. 60 seconds 110W Relative humidity: Non-condensing 5% to 95% RH Altitude: Operating 10,000 feet max. Non-operating 40,000 feet max. Vibration (See Note 11): 5-500 Hz 2.4 G rms peak