process yellow 116 1375 1797 375 3405 313 2985 240 Embedded Power for Business-Critical Continuity 242 2607 Rev. 02.10.09 152 NLP110 Series 1 of 4 652 NLP110 Series Single and Triple Output Total Power: 80-110 Watts Input Voltage: 90 -264 VAC of Outputs: Single, Triple Electrical Specifications Special Features Input Provides low voltage outputs Universal input Input range: 90-264 Vac Compliance to EN61000-3-2 (See Note 6) (Power Factor = 0.98) Frequency: 47-63 Hz 90 Vac to 264 Vac universal Input surge current: 120 Vac 18 A max. input range (cold start) 230 Vac 35 A max. UL, CSA and VDE safety Safety ground 120 Vac, 60 Hz 0.45 mA approvals and CE-Marked to leakage current: 230 Vac, 50 Hz 0.75 mA LVD Input current: 120 Vac 80 W 0.9 A rms Overvoltage and short circuit 120 Vac 110 W 1.3 A rms protection 230 Vac 80 W 0.48 A rms VDE0871-B, EN55022-B, 230 Vac 110 W 0.7 A rms EN55011-B conducted noise Input fuse: UL/IEC127 F3.15A H, 250 Vac VDE0871-A, EN55022-A, EN55011-A radiated noise Output Meets all applicable and Total regulation: Main output 2.0% relevant immunity standards (line and load) Auxiliary outputs 5.0% EN61000-4-2,4,5 and 6 Rise time: At turn-on 1.0 s, max. RoHS compliant Transient response: Main output 5.0% or 250 mV 2 year warranty 75% to 100% max. dev., 1 ms max. step at 0.1 A s recovery to 1% Temperature coefficient: 0.02%/C Overvoltage protection: Main outputs 125%, 10% Safety Short circuit protection: Cyclic operation Continuous VDE0805/EN60950/IEC950 File No. 10401-3336-1096 Minimum output current: Single and multiple See table All specifications are typical at nominal input, full load at 25 C unless otherwise stated. UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062 CCC Markprocess yellow 116 1375 1797 375 3405 313 2985 240 242 Embedded Power for Business-Critical Continuity 2607 Rev. 02.10.09 152 EMC Characteristics NLP110 Series 2 of 4 652 Conducted emissions: EN55022, FCC part 15 Level B Radiated emissions: EN55022, FCC part 15 Level A Harmonic current emission correction: EN61000-3-2 Compliant ESD air: EN61000-4-2 Level 3 ESD contact: EN61000-4-2 Level 3 Surge: EN61000-4-5 Level 3 Fast transients: EN61000-4-4 Level 3 Radiated immunity: EN61000-4-3 Level 3 EN61000-4-6 Level 3 Conducted immunity: General Specifications Hold-up time: 120 Vac, 60 Hz 16.7 ms 110 W Efficiency: 120 Vac. 80 W (-9905J) 75% min. Isolation voltage: Input/output 3000 Vac Input/chassis 1500 Vac Approvals and standards pending: EN60950, VDE0805, IEC950, UL1950, CSA C22.2 No. 950 Weight: 283 g (10 oz) MTBF demonstrated: M I L-HDB K-217F 220,000 hours min. Environmental Specifications Thermal performance: Operating, ambient 0 C to +50 C (see derating curve) Non-operating -40 C to +85 C 50 C to 70 C ambient convection cooled Derate to 50% load 0 C to +50 C, ambient convection cooled 80 W 0 C to +50 C, ambient, 150 LFM forced air 110 W Peak (0 C to +50 C, 60 s) (See Note 3) Relative humidity: Non-condensing 5% to 95% RH Altitude: Operating 10,000 feet max. Non-operating 30,000 feet max. Vibration (See Note 5): 5-500 Hz 2.4 G rms peak Shock per MIL-STD-810E 516.4 Part IV DERATING CURVE Output Power (Watts) 110W 150 LFM FORCED AIR COOLING 80W NATURAL 55W CONVECTION 40W COOLING 0C 10C 20C 30C 40C 50C 60C 70C