NLP150L Series Single and triple output s LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 110-150 W AC/DC Universal Input Switch Mode Power Supplies 1 90 Vac to 264 Vac universal input range Provides low voltage outputs of 3.3 V EN61000-3-2 compliant Overvoltage and short circuit protection Power fail detection Current sharing (on V and V ) A B 3.8 x 6.8 x 1.26 inches UL, CSA and VDE safety approvals and CE-marked to LVD Compliance to EN55022-B conducted noise standard Compliance to EN55022-A radiated noise standard Meets all applicable and relevant immunity standards EN61000-4-2, -3, -4, -5 and -6 Available RoHS compliant The NLP150L series of 150 Watt ac-dc open-frame power supplies are available with single, triple or quad outputs. The single and triple output versions described in this datasheet are housed in a 3.8 x 6.8 x 1.26 inch package. All NLP150L series power supplies are harmonic current corrected to meet the EN61000-3-2 standard, and support current sharing. The power supplies are designed for use in 1U shelves or boxes, and are primarily intended for networking applications that have a heavy logic content, such as access concentrators, midrange routers, LAN switches and shared media hubs. 2 YEAR WARRANTY All speci cations are typical at nominal input, full load at 25 C unless otherwise stated SPECIFICATIONS (10) OUTPUT SPECIFICATIONS EMC CHARACTERISTICS (continued) Total regulation Main output 2.0% Surge EN61000-4-5 Level 3 Fast transients EN61000-4-4 Level 3 (Line and load) Auxiliary outputs 5.0% Radiated immunity EN61000-4-3 Level 3 Turn-on delay 120 Vac Input 2.0 s, max. Conducted immunity EN61000-4-6 Level 3 Transient response Main output 5.0% or 250 mV GENERAL SPECIFICATIONS 75% to 100% max. dev., 1 ms max. Hold-up time 120 Vac 60 Hz 20 ms 150 W step at 0.1 A/s recovery to 1% E ciency (See Note 13) 120 Vac 150 W 73% typical Temperature coefficient 0.02% /C Isolation voltage Input/output 3000 Vac Overvoltage protection Main outputs 125%, 10% Input/chassis 1500 Vac Short circuit protection Cyclic operation Continuous Approvals and E N60950, VDE 0805, IE C 950 standards pending UL1950, CSA C22.2 No. 950 Minimum output current Singles and multiple See table Weight 540 g (19 oz) INPUT SPECIFICATIONS MTBF ( 25 C) MIL-HDBK-217F 350,000 hours min. Input voltage range Universal input 90-264 Vac Bellcore 800,000 hours min. (See Note 12) Input frequency range 47-63 Hz (8) ENVIRONMENTAL SPECIFICATIONS Input surge current 264 Vac (cold start) 40 A max. Thermal performance Operating ambient, 0 C to +50 C (See derating curve) Safety ground 264 Vac, 60 Hz 0.99 mA Non-operating -40 C to +85 C leakage current 50 C to 70 C ambient, Derate to convection cooled 50% load Input current 120 Vac 150 W 1.95 A rms 230 Vac 150 W 1.10 A rms 0 C to 50 C ambient, 110 W convection cooled Input fuse UL/IEC127 F3.15A H, 250 Vac 0 C to 50 C ambient, 150 W 300 LFM forced air (10) EMC CHARACTERISTICS Peak (0 C to +50 C) (See Note 3) Conducted emissions EN55022, FCC part 15 Level B Relative humidity Non-condensing 5% to 95% RH Radiated emissions EN55022, FCC part 15 Level A Altitude Operating 10,000 feet max. Harmonic current EN61000-3-2 Compliant Non-operating 30,000 feet max. emission correction ESD air EN61000-4-2 Level 3 Vibration (See Note 6) 5-500 Hz 2.4 G rms peak ESD contact EN61000-4-2 Level 3 Shock per MIL-STD-810E 516.4 Part IV File Name: nlp150lst.pdf Rev (03): 08 Nov 2005NLP150L Series Single and triple outputs LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 110-150 W AC/DC Universal Input Switch Mode Power Supplies 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm OUTPUT CURRENT OUTPUT TOTAL MODEL (4) RIPPLE (5) (1) (2) (14,15) VOLTAGE MIN MAX 300 LFM REGULATION NUMBERS 3.3 V (V)1 A 22 A 30 A 50 mV 2.0% NLP150L-96S3J A 5.1 V (V)1 A 22 A 30 A 50 mV 2.0% NLP150L-96S5J A +12 V (V ) 0.3 A 9.2 A 12.5 A 120 mV 2.0% NLP150L-96S6J A 24 V (V ) 0.15 A 4.6 A 6.5 A 240 mV 2.0% NLP150L-96S8J A 48 V (V ) 0.1 A 2.3 A 3.2 A 480 mV 2.0% NLP150L-96S9J A +5.1 V (V ) 1.5 A 20 A 30 A 50 mV 2.0% NLP150L-96T536J A +3.3 V (V ) 0.5 A 10 A 15 A 50 mV 2.0% B +12 V (V)0 A2 A3 A 120 mV 5.0% C +12 V (V ) 0.6 A 9.2 A 12.5 A 120 mV 2.0% NLP150L-96T658J A +5.1 V (V ) 0.5 A 6 A 8 A 50 mV 2.0% B +24 V (V)0 A2 A3 A 240 mV 5.0% C Notes 1 Free air convection. Multiple output units: maximum continuous output power not to exceed DERATING CURVE 110 W and the output current not to exceed: I +I +2(I )23 A. A B C Output Power (Watts) 2 300 LFM forced air cooling from the longer side. Multiple output units: maximum continuous output power not to exceed 150W 150 W and the output current not to exceed: I +I +2(I )32 A. 300 LFM FORCED A B C 3 Peak power at 115% lasting less than 30 seconds with duty cycle less than AIR COOLING 5%. During peak loading, output voltage may exceed total regulation limits. 110W 4 Figure is peak-to-peak for room temperature rating. Output noise measurements are made across a 20 MHz bandwidth using a 6 inch twisted pair, terminated with a 10 F electrolytic capacitor and a 0.1 F ceramic capacitor. NATURAL 75W 5 Minimum load required for correct start-up and operation on single outputs CONVECTION and on main output of multiple versions. Failure to observe minimum load 55W on main output will not allow the supply to start-up correctly. Some COOLING electronic test loads have a large delay time before they start drawing current even though the voltage from the supply is present. During this time delay, there is no load on the output and as a result, the supply may not be able to start-up properly and maintain its correct output voltage. In these instances, a dummy resistive load across the output may be necessary to load the output of the supply until the test load can function correctly and 0C 10C 20C 30C 40C 50C 60C 70C draw the intended minimum load. Minimum load required on auxiliary outputs to maintain regulation. 6 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5 Hz to 500 Hz. 7 For optimum reliability no part of the heatsink should exceed 110 C and no semi-conductor case temperature should exceed 115 C. 8 CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. 9 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 10 Conducted EMI specifications reference measurements made with the power supply mounted on a grounded metal sheet extending 1 inch beyond each edge, using an unshielded cable. No external filtering required during conducted emissions testing but some applications may require additional filtering to achieve system compliance. Compliance with Radiated EMI specifications may require mounting in a suitable enclosure. 11 All models require a minimum mounting stand-off of 6.35 mm (0.25 inches) in the end use product. 12 Operational range 90 Vac to 264 Vac. 13 For 3.3 V ouput (single), typical efficiency is 69%. 14 The J suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on International Safety Standard Approvals special request, please contact your local sales representative for details. 15 NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at VDE0805/EN60950/IEC950 File No. 10401-3336-0162