NLP25 Series Single, dual and triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 20-25 W AC/DC Universal Input Switch Mode Power Supplies 1 4.00 x 2.07 x 0.91 inch package Overvoltage protection and short circuit protection 25 W with free air convection cooling EN55022, EN55011 conducted emissions level B UL, VDE, CSA and CCC safety approvals Available RoHS compliant The NLP25 series is a 25 W universal input ac-dc power supply on a 4.00 x 2.07 inch card with a profile of less than 1 inch. The availability of four single output and three multiple output models in an extremely small package size make the NLP25 ideal for use in space critical, low power communication applications requiring an off line power solution. The NLP25 provides 25 W of output power with free air convection cooling which can peak at 30 W for 60 seconds. Standard features include overvoltage and short circuit protection. The series, with full international safety approvals and the CE mark, meets conducted emissions EN55022 level B and complies to EN61000-4-2,-3,-4, -5 and -6 immunity standards. The NLP25 series is designed for use in off line, low power data networking and computer applications with limited space, such as hubs, routers, POS terminals, external disk storage and cable modems. The availability of 5 V outputs in single and multiple configurations provides a solution for a myriad of microprocessor applications. 2 YEAR WARRANTY All specifications are typical at nominal input, full load at 25 C unless otherwise stated SPECIFICATIONS OUTPUT SPECIFICATIONS EMC CHARACTERISTICS Radiated emissions EN55022/11, FCC part 15 Level A Total regulation Main output 2.0% Conducted emissions EN55022/11, FCC part 15 Level B (Line and load) Auxiliary outputs 5.0% Electrostatic discharge EN61000-4-2 Level 2 Overshoot/undershoot At turn-on 2.0% Electrical fast EN61000-4-4 Level 3 transients/bursts Transient response Main output 5.0% max. dev., Surge susceptibility EN61000-4-5 Level 3 50% to 100% 1 ms recovery RF field susceptibility EN61000-4-3 Level 3 full load step to 1.0% RF conducted EN61000-4-6 Level 3 disturbance Temperature coefficient 0.02%/C GENERAL SPECIFICATIONS Overvoltage protection Main output See table Hold-up time 110 Vac full load 5 ms typ. Short circuit protection Continuous with autorestart Efficiency 110 Vac full load 70% typ. Minimum output current See table Isolation voltage Input/output 3000 Vac Input/chassis 1500 Vac INPUT SPECIFICATIONS Switching frequency Fixed 60 kHz, 10 kHz Input voltage range Universal input 90-264 Vac 127-375 Vdc Approvals and EN60950, IEC950 standards VDE0805, UL1950, CCC60950 Input frequency range 47-440 Hz (See Notes 4, 8) CSA C22.2 No. 950 Input current 90 Vac 0.75 A rms max. Weight 115 g (4 oz) 230 Vac 0.35 A rms max. MTBF MIL-HDBK-217F 150,000 hours min. Safety ground 120 Vac, 60 Hz 0.2 mA leakage current 230 Vac, 50 Hz 0.4 mA ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating ambient, FL 0 C to +50 C (See Notes 7, 8) Non-operating -40 C to +85 C 0 C to 50 C, ambient, Full load convection cooled Peak See Note 1 Relative humidity Non-condensing 5% to 95% RH Altitude Operating 10,000 feet max. Non-operating 30,000 feet max. Vibration (See Note 6) 5-500 Hz 2.4 G rms peak Shock MIL-STD-810E 516.4 Part IV File Name: NLP25.PDF Rev (02): 08 Nov 2005NLP25 Series Single, dual and triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 20-25 W AC/DC Universal Input Switch Mode Power Supplies 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm OUTPUT CURRENT OUTPUT OUTPUT OVP TOTAL MODEL (2) RIPPLE (3) (1) (5) (3) (9,10,11) POWER VOLTAGE MIN MAX PEAK THRESHOLD REGULATION NUMBER 20.8 W +5 V (I ) 0.2 A 2 A 2.5 A 50 mV 5.6-6.9 V 2.0% NLP25-7608J A +12 V (I ) 0.1 A 0.8 A 1.2 A 120 mV 5.0% B 12 V (I)0 A 0.1 A 0.15 A 50 mV 5.0% C 20.1 W +5 V (I ) 0.2 A 2 A 2.5 A 50 mV 5.6-6.9 V 2.0% NLP25-7607J A +12 V (I ) 0.1 A 0.8 A 1.2 A 120 mV 5.0% B 5 V (I)0 A 0.1 A 0.15 A 50 mV 5.0% C 19.6 W +5 V (I ) 0.2 A 2 A 2.5 A 50 mV 5.6-6.9 V 2.0% NLP25-7629J A +12 V (I ) 0.1 A 0.8 A 1.2 A 120 mV 5.0% B 25 W +5 V 0 A 5 A 6 A 50 mV 5.6-6.9 V 2.0% NLP25-7605J 25 W +12 V 0 A 2.08 A 2.5 A 120 mV 14-16.7 V 2.0% NLP25-7612J 25 W +24 V 0 A 1.04 A 1.25 A 150 mV 29-34.2 V 2.0% NLP25-7624J 25 W +48 V 0 A 0.52 A 0.6 A 150 mV 55-60 V 2.0% NLP25-7617J Notes OUTPUT PIN CONNECTIONS 1 Peak output current lasting less than 60 seconds with duty cycle less than J2 SINGLE DUAL TRIPLE 5.0%. During peak loading, output voltage may exceed total regulation limits. Pin 1 V (A) No Connection V (C) 2 20 MHz bandwidth, peak to peak, measured differentially with a 12 inch twisted pair of number 16 AWG copper wire, terminated with a 47 F Pin 2 Return Return Return capacitor of proper polarity and voltage rating. 3 Total regulation is defined as the static output regulation at 25 C, including Pin 3 V (A) V (A) V (A) initial tolerance, line voltage within stated limit, load current within stated Pin 4 Return Return Return limit, and output voltage adjusted to their factory settings. To achieve specified regulation on multiple output models, minimum loads are required Pin 5 V (A) V (B) V (B) on V(A) and V(B) as outlined in above table. 4 To maintain user-system safety approvals, the input power cable must be appropriately rated and approved. 5 Main output voltage is protected by a Zener diode. 6 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G INPUT rms 5 Hz to 500 Hz. 7 CAUTION: Allow a minimum of 5 seconds after disconnecting line power PIN CONNECTIONS when making thermal measurements. J1 8 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. Pin 1 AC Ground 9 All models of the NLP25 series are floating output except for the NLP25- 7612J unit. The NLP25-7612J unit has its 0 Vdc output (return on J2 pins Pin 3 AC Line 2 and 4) directly connected to the incoming earth/ac ground. For the NLP- 7612J floating output please consult Artesyn Technologies. Pin 5 AC Neutral 10 The J suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. 11 NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at