NLP40 Series Single, dual and triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50 W AC/DC Universal Input Switch Mode Power Supplies 1 4.25 x 2.5 x 1.15 inch package (1U applications) Smallest industry package Overvoltage and short circuit protection 40 W with free air convection EN55022, EN55011 conducted emission level B EN61000-4-2, -3, -4, -5, -6 immunity compliant UL, VDE and CSA safety approvals Available RoHS compliant The NLP40 series is a 40 W universal input ac-dc power supply on a 4.25 x 2.5 inch card with a maximum component height of 1.15 inches for use in 1U applications. This product is the smallest standard 40 W package in the industry making the series ideal for communication applications with space constraints where a standard 5 x 3 inch card solution is not suitable. The NLP40 provides 40 W of output power with free air convection cooling which can be boosted to 50 W with 20 CFM of air. Standard features include overvoltage and short circuit protection. The series, with full international safety approval and the CE mark, meets conducted noise EN55022 level B and has immunity compliance to EN61000-4-2,-3,-4, -5, -6. The NLP40 series is designed for use in low power data networking, computer and telecom applications such as hubs, routers, POS terminals, LCD projectors, cable modems and PABXs. This list is not exclusive as the generic feature set of the NLP40 series with industry standard output configurations provides a solution for most low power applications including many industrial applications. 2 YEAR WARRANTY All specifications are typical at nominal input, full load at 25 C unless otherwise stated SPECIFICATIONS OUTPUT SPECIFICATIONS GENERAL SPECIFICATIONS Total regulation Main output 2.0% Hold-up time 120 Vac 12 ms 40 W (Line and load) Auxiliary outputs 5.0% 230 Vac 20 ms 40 W Rise time At turn-on 1.0 s, max. Efficiency 75% typical Transient response Main output 5.0% max. dev., Isolation voltage Input/output 3000 Vac 25% step at 0.1 A/s 1 ms rec. to 1.0% Input/chassis 1500 Vac Temperature coefficient 0.02%/C Switching frequency Fixed 65 kHz, 5 kHz Overvoltage protection Main outputs 135%, 15% Approvals and EN60950, IEC950, UL1950 standards (See Note 8) VDE0805, CSA C22.2 No. 950 Short circuit protection Cyclic operation Continuous Weight 200 g (7.06 oz) Minimum output current Single 0 A Multiple (See Note 5) MTBF MIL-HDBK-217F 150,000 hours min. INPUT SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS Input voltage range Universal input 90-264 Vac Thermal performance Operating ambient, 0 C to +70 C (See Note 9) 120-370 Vdc (See Notes 6, 7, 9) (see derating curve) Non-operating -40 C to +70 C Input frequency range 47-440 Hz 50 C to 70 C ambient, Derate to convection cooled 50% load Input surge current 120 Vac, cold start 15 A max. 230 Vac, cold start 30 A max. 0 C to 50 C, ambient, 40 W convection cooled Safety ground 120 Vac, 60 Hz 0.2 mA 0 C to 50 C ambient, 50 W leakage current 230 Vac, 50 Hz 0.4 mA 20 CFM forced air Peak (0 C to +50 C, 60 s) (See Note 2) Input current 120 Vac 1.4 A rms 230 Vac 0.7 A rms Relative humidity Non-condensing 5% to 95% RH Input fuse UL/IEC127 250 Vac H 3.15 A Altitude Operating 10,000 feet max. Non-operating 30,000 feet max. (10) EMC CHARACTERISTICS Vibration (See Note 4) 5-500 Hz 2.4 G rms peak Conducted emissions EN55022, FCC part 15 level B Radiated emissions EN55022, FCC part 15 level A Shock per MIL-STD-810E 516.4 Part IV ESD air EN61000-4-2, level 3 Perf. criteria 1 ESD contact EN61000-4-2, level 3 Perf. criteria 1 Surge EN61000-4-5, level 3 Perf. criteria 1 Fast transients EN61000-4-4, level 3 Perf. criteria 1 Radiated immunity EN61000-4-3, level 3 Perf. criteria 1 Conducted immunity EN61000-4-6, level 3 Perf. criteria 1 File Name: nlp40.pdf Rev (03): 08 Nov 2005NLP40 Series Single, dual and triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50 W AC/DC Universal Input Switch Mode Power Supplies 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm OUTPUT CURRENT OUTPUT TOTAL (3) (11,12) RIPPLE MODEL NUMBER (1) (2) (1) VOLTAGE MAX PEAK FAN REGULATION (5) +3.3 V (I)4 A5 A 4.5 A 50 mV 2.0% NLP40-76T366J A +12 V (I)2 A3 A3 A 120 mV 5.0% B 12 V (I ) 0.2 A 1 A 0.5 A 120 mV 5.0% C (5) +5 V (I)4 A5 A 4.5 A 50 mV 2.0% NLP40-7608J A +12 V (I)2 A3 A3 A 120 mV 5.0% B 12 V (I ) 0.2 A 1 A 0.5 A 120 mV 5.0% C (5) +5 V (I)4 A5 A 4.5 A 50 mV 2.0% NLP40-7610J A +15 V (I ) 1.6 A 2 A 2 A 150 mV 5.0% B 15 V (I ) 0.2 A 1 A 0.5 A 150 mV 5.0% C (5) +12 V (I ) 1.8 A 2.2 A 2.1 A 120 mV 2.0% NLP40-7627J A -12 V (I ) 1.8 A 2.2 A 2.1 A 120 mV 5.0% B (5) +5 V (I)4 A5 A 4.5 A 50 mV 2.0% NLP40-7629J A +12 V (I)2 A3 A3 A 120 mV 5.0% B 3.3 V (I)8 A 10 A 9 A 50 mV 2.0% NLP40-76S3J A 5 V 8 A 10 A 9 A 50 mV 2.0% NLP40-7605J 12 V 3.3 A 4.5 A 4 A 120 mV 2.0% NLP40-7612J 15 V 2.6 A 3.6 A 3.3 A 150 mV 2.0% NLP40-7615J 24 V 1.6 A 2.5 A 2 A 240 mV 2.0% NLP40-7624J 48 V 0.8 A 1.1 A 1 A 300 mV 2.0% NLP40-7617J Notes DERATING CURVE 1 Maximum output power is 40 W for natural convection cooling. With Output Power (Watts) 20 CFM fan cooling, the maximum output power is 50 W. 2 Peak output current lasting less than 60 seconds with duty cycle less than 50W 5%. During peak loading, output voltage may exceed total reg. limits. 20 CFM FORCED AIR COOLING 3 Figure is peak-to-peak. Output noise measurements are made across a 50 MHz bandwidth using a 12 inch twisted pair, terminated with a 47 F 40W capacitor. 4 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5 Hz to 500 Hz. 5 For multiple output units (except -7627J, 76T366J) to maintain stated regulation then: 25W NATURAL 0.25 I / I 5, for I > 0.3 A A B B CONVECTION 0.50 I / I 5, for I < 0.3 A 20W A B B COOLING For maximum output current I(C) on triple output models, i.e. for I = IMax., I min. 0.5 A and I I . C A A B For NLP40-7627J only, to maintain stated regulation then: 0.5 I / I 2. A B For NLP40-76T366J only, to maintain stated regulation then: 0.25 I / I 4. A B 6 For optimum reliability, no part of the heatsink should exceed 120 C, and 0C 10C 20C 30C 40C 50C 60C 70C no semiconductor case temperature should exceed 130 C. 7 CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. 8 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 9 When the input voltage is <90 Vac the operating range is 0 C to +40 C. 10 For system EMI compliance, a ground choke may be required before connecting the ground wire to the chassis. It is recommended that this ground choke be placed as close as possible to the systems ac inlet to eliminate noise pick-up in the system. 11 The J suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. 12 NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at