Embedded Power for
Business-Critical Continuity
Rev.05.09.13_103
NLP65 Series
1 of 4
NLP65 Series
Single, dual,
and triple output
Total Power: 65 - 75W
Input Voltage: 85 - 264 Vac
120 - 370 Vdc*
# of Outputs: Single, dual,
triple
Electrical Specifications
Special Features
Input
Universal Input Input voltage range:
Universal input 85-264 Vac
3 x 5 footprint
(see Note 2)
Low profile fits 1U applications
NLP65-76xx version only 120-370 Vdc
EN61000-3-2 compliance
Input frequency range:
47-63 Hz
option (HCC)
Input current:
120 Vac 17 A max .
Overvoltage and short circuit
(cold start)
230 Vac 32 A max
protection
65 W with free air convection Safety ground
120 Vac, 60 Hz 0.7 mA
cooling leakage current:
230 Vac, 50 Hz 1.4 mA
EN55022, EN55011 conducted
Input current:
120 Vac, with PFC 1.4 A
emissions level B
230 Vac, with PFC 0.51 A rms
EN61000-4-2,-3,-4, -5, -6
120 Vac, without PFC 1.40 A rms
immunity compliant
230 Vac, without PFC 0.80 A rms
RoHS compliant
Input fuse:
UL/IEC127 5 A, 250 Vac In live and neutral
LPX80 enclosure kit available
2 year warranty Output
Total regulation:
Main output 2.0%
(line and load)
Auxiliary outputs 5.0%
Rise time:
At turn-on 1.0 s, max
Safety
Transient response:
Main output 5.0% or 250 mV
VDE0805/EN60950-1
25% step max. dev., 1ms max.
File No. 1040100-3336-0096
at 0.1 A/s recovery to 1%
License No. 114404
Temperature coefficient:
0.02%/C
UL 60950-1
Overvoltage protection:
Main outputs 125%, 10%
cUL 60950-1
Short circuit protection:
Cyclic operation Continuous
CCC 60950-1
Minimum output current:
Single and multiple (See Note 6)
CE LVD Directive
*NLP65-76xx version onlyEmbedded Power for
Business-Critical Continuity
All specifications are typical at nominal input, full load at 25 C unless otherwise stated.
Rev.05.09.13_103
NLP65 Series
2 of 4
(11, 12)
EMC Charateristics
Conducted emissions:
EN55022, FCC part 15 Level B
ESD air:
EN61000-4-2, level 3 Perf. criteria 1
ESD contact:
EN61000-4-2, level 4 Perf. criteria 1
Surge:
EN61000-4-5, level 3 Perf. criteria 1
Fast transients:
EN61000-4-4, level 3 Perf. criteria 1
Radiated immunity:
EN61000-4-3, level 3 Perf. criteria 2
Conducted immunity:
EN61000-4-6, level 3 Perf. criteria 2
General Specifications
Hold-up time:
120 Vac, 60 Hz 16 ms @ 65 W
230 Vac, 50 Hz 78 ms @ 65 W
Efficiency:
120 Vac, 65 W 72% typical
Isolation voltage:
Input/output 3000 Vac
Input/chassis 1500 Vac
Switching frequency:
Fixed 100 kHz, 5 kHz
Approvals and standards:
EN60950-1, IEC60950-1
(see Notes 9, 13)
Weight:
283 g (10 oz)
MTBF demonstrated:
MIL-HDBK-217F 150,000 hours min
Environmental Specifications
Thermal performance: Operating 0 C to +70 C
(See derating curve)
(See notes 1, 3, 10) Non-operating -40 C to +85 C
50 C - 70 C ambient, Derate to 50% load
convection cooled
0 C to 50 C, ambient, 65 W
convection cooled
0 C to 50 C, ambient 75 W
20CFM forced air (See Note 10)
Peak (0 C to 50 C, 60 s) See table
Relative humidity: Non-condensing 5 to 95% RH
Altitude: Operating 10,000 feet max.
Non-operating 30,000 feet max.
Vibration (See Note 5): 5-500 Hz 2.4 G rms peak
Shock per MIL-STD-810E 516.4 Part IV