POWER NLP65-M Data Sheet Single, Dual and Triple output Total Power: 65 W Input Voltage: 85-264 VAC of Outputs: Single, Dual, Triple Special FeatureS 85 VAC to 264 VAC universal input range Harmonic current correction as standard Maximum component height 1.26 inches UL, CSA and VDE safety approvals Overvoltage and short circuit protection 5 x 3 x 1.26 inch (127.0 x 76.2 x 32mm) footprint Electrical Specifications Available RoHS compliant Input 2 years warranty Input voltage range: Universal input (see Note 2) 85 - 264 Vac Input frequency range: 47-63 Hz SaFety Input current: 120 Vac 17 A max. (cold start) 230 Vac 32 A max UL60601-1/CAN/CSA-C22.2 No. 60601-1-M90 Safety ground leakage current: 264 Vac, 60 Hz 95 A VDE License No. 121949 under Input current: 120 Vac 1.05 A rms EN60601-1/IEC60601-1 230 Vac 0.51 A rms Input fuse: 250 Vac F 5 A Output Output power: Natural convection 65 W max. Total regulation: (line and load) See table Rise time: At turn-on 1.0 s, max Transient response: Main output 5.0% max. dev., 25% step at 0.1 A/s 1ms recovery to 1.0% Temperature coefficient: 0.02%/C Overvoltage protection: Main outputs 125%, 10% Short circuit protection: Cyclic operation YesNLP65-M Series Data Sheet All specifications are typical at nominal input, full load at 25C unless otherwise stated. EMC Charateristics Conducted emissions: EN55022, FCC part 15 Level A Radiated emissions: EN55022, FCC part 15 Level A ESD air: EN61000-4-2, level 3 Perf. criteria 1 ESD contact: EN61000-4-2, level 4 Perf. criteria 1 Surge: EN61000-4-5, level 3 Perf. criteria 1 Fast transients: EN61000-4-4, level 3 Perf. criteria 1 Radiated immunity: EN61000-4-3, level 3 Perf. criteria 2 Conducted immunity: EN61000-4-6, level 3 Perf. criteria 2 General Specifications Hold-up time: 120 Vac, 60 Hz 16 ms 65 W Efficiency: 120 Vac, 65 W 72% typical Isolation voltage: Input/output 4000 Vac Input/chassis 1500 Vac Switching frequency: Fixed 100 kHz, 5 kHz Approvals and standards: EN60601-1, IEC60601-1 Weight: 283 g (10 oz) MTBF demonstrated: MIL-HDBK-217F 150,000 hours Environmental Specifications Thermal performance: Operating (See derating curve) 0C to +70C Non-operating -40C to +85C 0C to 50C, ambient, convection cooled 65 W 50C - 70C ambient, convection cooled Derate to 50% load Peak (0C to 50C, 60 s) See table Relative humidity: Non-condensing 5 to 95% RH Altitude: Operating 10,000 feet max. Non-operating 30,000 feet max. Vibration (See Note 5): 5-500 Hz 2.4 G rms approx. Shock per MIL-STD-810E 516.4 Part IV DERATING CURVE Output Power(Walts) 75W 20 CFM FORCED AIR COOLING 65W NATURAL 38W CONVECTION 32W COOLING 0C 10C 20C 30C 40C 50C 60C 70C