ARTESYN TLP150 MEDICAL SERIES Single Output Advanced Energy s Artesyn TLP150 series of open-frame DATA SHEET AC-DC power supplies comprises two single output models, offering a main voltage of 12 V or 24 V. Each model also Total Power: provides 12 V fan and 5 V standby outputs. Both models 150 Watt feature medical safety approvals and accept a universal input of 85264 Vac. Comprehensive overcurrent, overvoltage Input Voltage: and overtemperature protection is provided as standard. 85 - 264 Vac Additional features include main output remote sense, active of Outputs: current sharing and integrated control and monitoring facilities. TLP150-M series power supplies provide 100 watts of output Single power with free air convection cooling and 150 watts with 200 LFM of forced air. Less than 1U high, they are ideal for systems that implement distributed power architectures (DPA) and point-of-load (POL) schemes, as well as for powering electromechanical devices and non-patient contact and non-patient critical medical applications. SPECIAL FEATURES SAFETY 150 W on main channel with only TUV EN60601-1/IEC60601-1 200 LFM VDE CB Certificate and Report Low profile fits 1U applications UL 60950-1 Active PFC and EN61000-3-2 compliant Integrated control and monitoring features Overcurrent, overvoltage and overtemperature protection Compliance to EN55022-B conducted noise standard 12 V fan output 5 V standby output (optional) RoHS compliant 2021 Advanced Energy Industries, Inc. Two years warrantyTLP150M ELECTRICAL SPECIFICATIONS Input Input voltage range Universal Input 85 - 264 Vac Input frequency range 47 - 63 Hz Input surge current 264 Vac (cold start) 40 A max. Safety ground leakage current 264 Vac, 50 Hz 150 A Input current 120 Vac 150 W 1.8 A rms 230 Vac 150 W 0.8 A rms Input fuse: UL/IEC127 T 3.15 A, 250 Vac Output Adjustment range 10% Total regulation (line and load) Main output 3% Auxiliary outputs 5% Fan output 10% Turn-on delay 120 Vac Input 2.0 s max. Transient response Main output 5% 25% to 75% max. dev., 1 ms max. step at 0.5 A/s recovery to 1% Temperature coefficient 0.02%/C Overvoltage protection Main outputs 125%, 5% Short circuit protection Current limited Continuous Minimum output current Singles 0 A Fan voltage output See Note 9 12 V 0.5 A Standby output See Note 9 5 V 1.0 A (5) EMC CHARACTERISTICS Conducted emissions EN55022, FCC part 15 Level B Harmonic current correction EN61000-3-2 Compliant ESD air EN61000-4-2 Level 3 ESD contact EN61000-4-2 Level 3 Radiated immunity EN61000-4-3 Level 3 Fast transients EN61000-4-4 Level 4 Surge EN61000-4-5 Level 3 Conducted immunity EN61000-4-6 Level 3 2 advancedenergy.com