ARTESYN TLP150 SERiES Single Output Advanced Energy s Artesyn TLP150 series of open-frame DATA SHEET AC-DC power supplies comprises four single output models, offering voltages of 12 V, 24 V, 36 V or 48 V. Each model also Total Power: provides 12 V fan and 5 V standby outputs. All four models 150 Watt accept a universal input of 85264 Vac. Comprehensive overcurrent, overvoltage and overtemperature protection is input Voltage: provided as standard. Additional features include main output 85 - 264 Vac remote sense, active current sharing and integrated control of Outputs: and monitoring facilities. TLP150 series power supplies provide 100 watts of output power with free air convection cooling Single and 150 watts with 200 LFM of forced air. Less than 1U high, they are ideal for systems that implement distributed power architectures (DPA) and point-of-load (POL) schemes. SPECiAL FEATURES SAFETY 150 W on main channel with only TUV EN60950-1/IEC60950-1 200 LFM UL60950-1/CSA22.2 No.60950-1 Low profile fits 1U applications Active PFC and EN61000-3-2 compliant Integrated Or-ing diode Active current sharing Integrated control and monitoring features Overcurrent, overvoltage and overtemperature protection Compliance to EN55022-B conducted noise standard 12 V fan output 5 V standby output (optional) RoHS compliant Two years warranty 2021 Advanced Energy Industries, Inc.TLP150 ELECTRiCAL SPECiFiCATiONS Output Adjustment range 10% Total regulation Main output 3% (line and load) Auxiliary outputs 5% Fan output 10% Turn-on delay 120 Vac input 2.0 s max. Transient response Main output 5% 25% to 75% max. dev., 1 ms max. step at 0.5 A/s recovery to 1% Temperature coefficient 0.02%/C Overvoltage protection Main outputs 125% 5% Short circuit protection Current limited Continuous Minimum output current Singles 0 A Fan voltage output See Note 9 12 V 0.5 A Standby output See Note 9 5 V 1.0 A input Input voltage range Universal input 85 - 264 Vac Input frequency range 47 - 63 Hz Input surge current 264 Vac (cold start) 40 A max. Safety ground leakage current 264 Vac, 50 Hz 1 mA Input current 100 Vac 250 W 2.5 A rms 120 Vac 250 W 1.8 A rms 230 Vac 250 W 0.8 A rms Input fuse UL/iEC127 T 3.15 A, 250 Vac EMC CHARACTERiSTiCS Conducted emissions EN55022, FCC part 15 Level B Harmonic current correction EN61000-3-2 Compliant ESD air EN61000-4-2 Level 3 ESD contact EN61000-4-2 Level 3 EN61000-4-4 Level 4 Fast transients Surge EN61000-4-5 Level 3 Conducted immunity EN61000-4-6 Level 3 2 advancedenergy.com