240 WATT AC-DC CONVERTER PLEY-HSZ SERIES Specifications<AC/DC> Model PLEY**HSZ-U PLEY12HSZ-U PLEY24HSZ-U PLEY36HSZ-U 240WATTS(Peak 300-360W)/SINGLE Input Characteristic Input Voltage AC115/230V(by selector) Input Current 5.5A at AC115V/2.8A at AC230V Input Range AC85-132V/170-264V Input Frequency 50/60Hz Input Frequency Range 47-440Hz Phase Single Inrush Current *1 17.5A(maximum)at AC115V/35A(maximum) at AC230V Efficiency % (typical) *2 83/85 86/88 87/88 Dimension (mm) ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales eta-usa.com PLE**HSZ Specification Specifications<AC/DC> Model PLEY**HSZ-U PLEY12HSZ-U PLEY24HSZ-U PLEY36HSZ-U 240WATTS(Peak 300-360W)/SINGLE Output Characteristic Output Voltage V 12 24 36 Output Current A 18.0(Peak 25.0) 10.0(Peak 15.0) 6.8(Peak 10.0) Voltage Adjust Range +/- 10% of Rated Output Voltage(at no load within the input range) Ripple and Noise mVp-p (maximum) *3 220 340 460 Regulation Statistic Line Regulation mV (maximum) 96 192 288 Statistic Load Regulation mV (maximum) 108 216 324 Temperature Coefficient *4 0.03%/ Drift mV (maximum) *5 75 135 195 Dynamic Load Regulation mV (typical) *6 360 720 1080 Recovery Time *6 0.5mS(typical) and rated input/output Rise up time 500mS(maximum) at 25 Hold up time 20mS(minimum) at 25 and rated input/output Functions Current Limiting with automatic recovery Overcurrent Protection A (minimum) 25.15 16.2 10.5 Output shutdown(to reset,leave 1minute after shut-off) Overvoltage Protection 110% of Rated 13.2 26.4 39.6 Output Voltage V Remote Sense not available Remote On/Off option Environmental Operating Temperature *7 0 to +50 /enclosed type: -5 to +40 Operating Humidity 30 to 85%RH(non-condensing) Storage Temperature -20 to +85 Celsius Storage Humidity 10 to 85%RH(non-condensing) Primary-Secondary AC3,000V for 1minute Withstanding Voltage Primary-Frame Ground AC3,000V for 1minute Secondary-Frame Ground AC500V for 1minute Primary-Secondary-Frame Ground 50M(minimum) by DC500V insulation tester Isolation Resistance 2 Vibration 5-10Hz:10mm double amplitude,10-55Hz:19.6m/s ,20minutes period for 60minutes each along X,Y,Z axes(non-operating) 2 Shock 294m/s Cooling Convection Leakage Current 1mA(maximum) at 25 ,rated input/output and rated input frequency Built to meet VDE0871 Class A Line Conducted Noise Built to meet FCC Part15-B Class A UL: UL1950 Safety CUL: CSA C22.2 No950 VDE: EN60950,IEC950,VDE0805 Weight (typical) 1,130g/enclosed type:1,260g MTBF H 480,000 Switching Frequency kHz (typical) 90 Conditions: *1 at cold start *2 at AC115/20V and at 25 Celsius *3 measured by a bayonet probe at output connector at 0 to 100MHz bandwidth *4 at 0 to +50 Celsius *5 for 7hour period after 1hour warm-up at 25 Celsius and rated input/output *6 when output current changed from 25% and 75% of rated output current rapidly at AC115/230V input *7 safety approved at 25 Celsius ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales eta-usa.com