60 Series - General purpose relays 6 - 10 A Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listed (certain relay/socket combinations) Contact material options 2 pole - 10 A power contacts 3 pole - 10 A power contacts Lockable test button with mechanical flag 8 pin plug-in 11 pin plug-in indicator (preferred version) 90 series sockets, coil EMC suppression and timer accessories 124 225 225 216 247 143 246 124 328 111 218 143 349 60 111 3111 A12 A27 A12 A210 32.5 36.4 32.5 36.4 Contact specification Contact configuration 2 CO (DPDT) 3 CO (3PDT) Rated current/Maximum peak current A 10/20 10/20 Rated voltage/Maximum switching voltage V AC 250/400 250/400 Rated load AC1 VA 2,500 2,500 Rated load AC15 (230 V AC) VA 500 500 Single phase motor rating (230 V AC) kW 0.37 0.37 Breaking capacity DC1: 30/110/220 V A 10/0.4/0.15 10/0.4/0.15 Minimum switching load mW (V/mA) 500 (10/5) 500 (10/5) Standard contact material AgNi AgNi Coil specification Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 N V DC 6 - 12 - 24 - 48 - 60 - 110 -125 - 220 Rated power AC/DC VA (50 Hz)/W 2.2/1.3 2.2/1.3 Operating range AC (0.81.1)U (0.81.1)U N N DC (0.81.1)U (0.81.1)U N N Holding voltage AC/DC 0.8 U /0.5 U 0.8 U /0.5 U N N N N Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U N N N N Technical data 6 6 6 6 Mechanical life AC/DC cycles 20 10 /50 10 20 10 /50 10 3 3 Electrical life at rated load AC1 cycles 200 10 200 10 Operate/release time ms 9/9 9/9 Insulation between coil and contacts (1.2/50 s) kV 3.6 3.6 Dielectric strength between open contacts V AC 1,000 1,000 Ambient temperature range C 40+70 40+70 Environmental protection RT I RT I Approvals (according to type) 83 12.6 54.2 12.6 54.260 Series - General purpose relays 6 - 10 A Features 60.12 - 0200 60.13 - 0200 Plug-in mount - 6 A Bifurcated contacts for low level switching 2 & 3 pole changeover contacts Cadmium Free contacts (Gold plated Silver Nickel) AC coils & DC coils Lockable test button with mechanical flag indicator (preferred version) 90 series sockets, coil EMC suppression 2 pole - 6 A bifurcated contacts 3 pole - 6 A bifurcated contacts and timer accessories 11 pin plug-in 8 pin plug-in 124 225 225 216 247 143 246 124 328 111 218 143 349 60 111 3111 A12 A27 A12 A210 32.5 36.4 32.5 36.4 Contact specification Contact configuration 2 CO (DPDT) 3 CO (3PDT) Rated current/Maximum peak current A 6/10 6/10 Rated voltage/Maximum switching voltage V AC 250/400 250/400 Rated load AC1 VA 1,500 1,500 Rated load AC15 (230 V AC) VA 250 250 Single phase motor rating (230 V AC) kW 0.185 0.185 Breaking capacity DC1: 30/110/220 V A 6/0.3/0.12 6/0.3/0.12 Minimum switching load mW (V/mA) 50 (5/5) 50 (5/5) Standard contact material AgNi + Au bifurcated contacts AgNi + Au bifurcated contacts Coil specification Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 N V DC 6 - 12 - 24 - 48 - 60 - 110 -125 - 220 Rated power AC/DC VA (50 Hz)/W 2.2/1.3 2.2/1.3 Operating range AC (0.81.1)U (0.81.1)U N N DC (0.81.1)U (0.81.1)U N N Holding voltage AC/DC 0.8 U /0.5 U 0.8 U /0.5 U N N N N Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U N N N N Technical data 6 6 6 6 Mechanical life AC/DC cycles 20 10 /50 10 20 10 /50 10 3 3 Electrical life at rated load AC1 cycles 250 10 250 10 Operate/release time ms 9/9 9/9 Insulation between coil and contacts (1.2/50 s) kV 3.6 3.6 Dielectric strength between open contacts V AC 1,000 1,000 Ambient temperature range C 40+70 40+70 Environmental protection RT I RT I Approvals (according to type) 84 12.6 54.2 12.6 54.2