SIL 2 Switch/Proximity Detector Repeater Transistor Output DIN-Rail D1033 Models D1033D, D1033Q Characteristics: Technical Data: General Description: Supply: The Switch/Proximity Detector Repeater type D1033 is a DIN Rail unit with two or four 24 Vdc nom (20 to 30 Vdc) reverse polarity protected, independent and isolated channels. The unit can be configured for contact or proximity ripple within voltage limits 5 Vpp. detector, NO or NC and for NC or NO optocoupled open collector transistor output. Current consumption 24 V: 55 mA for 4 channels D1033Q, Each channel enables a Safe Area load to be controlled by a switch, or a proximity 35 mA for 2 channels D1033D with input closed and transistors energized. detector, located in Hazardous Area. Power dissipation: 1.3 W for 4 channels D1033Q, 0.9 W for 2 channels D1033Q D1033Q quad channel type has four independent input channels and actuates the with 24 V supply voltage, input closed and transistors energized. corresponding output transistor. Two actuation modes can be independently DIP switch Max. power consumption: at 30 V supply voltage, short circuit input and configured on each input channel: NO input/NC transistor or NO input/NO transistor. transistors energized, 1.5 W for 4 channels D1033Q, 1.1 W for 2 channels D1033D. Contact or proximity sensor and its connection line short or open circuit fault detection is Isolation (Test Voltage): also DIP switch configurable: fault detection can be enabled (in case of fault it de-energizes the corresponding output transistor and turns the fault LED on) or disabled I.S. In/Out 1.5 KV I.S. In/Supply 1.5 KV I.S. In/I.S. In 500 V (in case of fault the corresponding output transistor repeats the input line open or closed Out/Supply 500 V Out 1-3/Out 2-4 500 V. status as configured). Input switching current levels: D1033D dual channel type has two input channels and four output transistors ON 2.1 mA, OFF 1.2 mA, switch current 1.65 mA 0.2 mA hysteresis. the unit has two DIP switch configurable operating modes: Fault current levels: open fault 0.2 mA, short fault 6.8 mA Mode A) input channel actuates in parallel the two output transistors. (when enabled both faults de-energize channel transistor with quad channel Transistor actuation mode can be independently configured for each output in two unit D1033Q or actuate fault transistor with dual channel unit D1033D). modes: NO input/NC transistor or NO input/NO transistor. Input equivalent source: 8 V 1 K typical (8 V no load, 8 mA short circuit). Mode B) input channel actuates output transistor A configurable in two modes as in Output: mode A above. Output transistor B operates as a fault output (in case of input fault, voltage free SPST optocoupled open-collector transistor. transistor B actuates and the fault LED turns on while transistor A repeats the input line Open-collector rating: 100 mA at 35 V as configured). Actuation can be DIP switch configured in two modes: No input fault/energized transistor (it de-energizes in case of fault) or ( 2.5 V voltage drop or 1.0 V voltage drop for versions -052 and -058). No input fault/de-energized transistor (it energizes in case of fault). Leakage current: 50 A at 35 V. Function:2 or 4 channels I.S. switch repeater for contact or EN60947-5-6 proximity. Response time: 500 s. Provides 3 port isolation (input/output/supply). Line-fault detection, common to all Frequency response: 2 KHz maximum. input signals, available when using Power Bus enclosure. Compatibility: Signalling LEDs: Power supply indication (green), output status (yellow), line fault (red). CE mark compliant, conforms to Directive: Field Configurability: NO/NC input for contact/proximitor, NC/NO transistor operation 2014/34/EU ATEX, 2014/30/EU EMC, 2014/35/EU LVD, 2011/65/EU RoHS. and fault detection enable/disable. Environmental conditions: EMC: Fully compliant with CE marking applicable requirements. Operating: temperature limits -20 to + 60 C, relative humidity max 95%. Functional Safety Management Certification: Storage: temperature limits 45 to + 80 C. FSM G.M. International is certified by TUV to conform to IEC61508:2010 SIL 3 Safety Description: part 1 clauses 5-6 for safety related systems up to and included SIL3. Front Panel and Features: ATEX: II (1) G Ex ia Ga IIC, II (1) D Ex ia Da IIIC,I (M1) Ex ia Ma I, II 3G Ex nA IIC T4 Gc IECEx / INMETRO: Ex ia Ga IIC, Ex ia Ma I, Ex ia Da IIIC, Ex nA IIC T4 Gc UL: NI / I / 2 / ABCD / T4, AIS / I, II, III / 1 / ABCDEFG, AEx nC ia IIC SIL 2 according to IEC 61508:2010 Ed.2 1 2 3 4 for Tproof = 6 / 10 years ( 10% / >10 % of total SIF). C-UL: NI / I / 2 / ABCD / T4, AIS / I, II, III / 1 / ABCDEFG, Ex nC ia IIC PFDavg (1 year) 1.54 E-04, SFF 75.41 %. FM: NI / I / 2 / ABCD / T4, NI / I / 2 / IIC / T4, AIS / I, II, III / 1 / ABCDEFG, AEx ia IIC SIL 3 Systematic capability FM-C: NI / I / 2 / ABCD / T4, NI / I / 2 / IIC / T4, AIS / I, II, III / 1 / ABCDEFG, Ex ia IIC 5 6 7 8 EAC-EX: 2Ex nA ia Ga IIC T4 Gc X, Ex ia Da IIIC X, Ex ia Ma I X Input from Zone 0 (Zone 20), Division 1, UKR TR n. 898: 2ExnAiaIICT4 X, ExiaI X installation in Zone 2, Division 2. NO/NC contact/proximity Detector Input. associated electrical apparatus. Uo/Voc = 9.6 V, Io/Isc = 10 mA, Po/Po = 24 mW at terminals13-14, 15-16, 9-10, 11-12. Four opto isolated voltage free transistor Um = 250 Vrms, -20 C Ta 60 C. Output Signals. Approvals: Common negative or positive output both DMT 01 ATEX E 042 X conforms to EN60079-0, EN60079-11, EN60079-26. accepted in standard version D1033. IECEx BVS 07.0027X conforms to IEC60079-0, IEC60079-11, IEC60079-26, Transistor Output for fault detection on dual channel version. IMQ 09 ATEX 013 X conforms to EN60079-0, EN60079-15, Line fault detection with common signalling IECEx IMQ 13.0011X conforms to IEC60079-0, IEC60079-15 available when using Power Bus enclosure. INMETRO DNV 13.0108 X conforms to ABNT NBR IEC60079-0, ABNT NBR IEC60079-11, PWR ON Three port isolation, Input/Output/Supply. ABNT NBR IEC60079-15, ABNT NBR IEC60079-26. 1 2 UL & C-UL E222308 conforms to UL913, UL 60079-0, UL60079-11, UL60079-15 EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1. ANSI/ISA 12.12.01 for UL and CSA-C22.2 No.157-92, CSA-E60079-0, CSA-E60079-11, 3 4 In-field programmability by DIP Switch. CSA-C22.2 No. 213 and CSA-E60079-15 for C-UL. STATUS/ FM & FM-C No. 3024643, 3029921C, conforms to Class 3600, 3610, 3611, 3810, ATEX, IECEx, UL & C-UL, FM & FM-C, INMETRO, FAULT EAC-EX, UKR TR n. 898, TV Certifications. ANSI/ISA 12.12.02, ANSI/ISA 60079-0, ANSI/ISA 60079-11, C22.2 No.142, C22.2 No.157, C22.2 No.213, E60079-0, E60079-11, E60079-15, TV Functional Safety Certification. D1033 C-IT.MH04.B.00306 conforms to GOST R IEC 60079-0,GOST R IEC 60079-11, Type Approval Certificate DNV and KR for maritime applications. GOST R IEC 60079-15. C 16.0034 X conforms to 7113, 22782.5-78, I 60079-15. High Reliability, SMD components. 9 10 11 12 TV Certificate No. C-IS-236198-03, SIL 2 conforms to IEC61508:2010 Ed.2. High Density, four channels per unit. TV Certificate No. C-IS-236198-09, SIL 3 Functional Safety Certificate conforms to Simplified installation using standard IEC61508:2010 Ed.2, for Management of Functional Safety. DIN Rail and plug-in terminal blocks. 13 14 15 16 DNV No.A-13778 and KR No.MIL20769-EL001 Certificates for maritime applications. 250 Vrms (Um) max. voltage allowed to the Mounting: instruments associated with the barrier. T35 DIN Rail according to EN50022. Weight: about 165 g D1033Q, 140 g D1033D. Ordering Information: Connection: by polarized plug-in disconnect screw terminal blocks to accomodate 2 terminations up to 2.5 mm . Model: D1033 Location: Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4, Class I, Division 2, Groups A, B, C, D Temperature Code T4 and 2 channels D Class I, Zone 2, Group IIC, IIB, IIA T4 installation. 4 channels Q Protection class: IP 20. Common negative and positive blank Common negative only -052 Power Bus and DIN-Rail accessories: Common positive only -058 DIN rail anchor MCHP065 DIN rail stopper MOR016 Power Bus enclosure /B Terminal block male MOR017 Terminal block female MOR022 G.M. International DTS0151-17 Page 1/2 www.gmintsrl.com Parameters Table: Image: Safety Description Maximum External Parameters Group Co/Ca Lo/La Lo/Ro Cenelec (F) (mH) (H/) Terminals 13-14, 15-16 9-10, 11-12 Uo/Voc = 9.6 V IIC 3.5 379 1530 Io/Isc = 10 mA IIB 25 1500 6150 Po/Po = 24 mW IIA 209 3000 12310 I 99 4900 20200 IIIC 25 1500 6150 NOTE for USA and Canada: IIC equal to Gas Groups A, B, C, D, E, F and G IIB equal to Gas Groups C, D, E, F and G IIA equal to Gas Groups D, E, F and G Function Diagram: HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC, SAFE AREA, ZONE 2 GROUP IIC T4, HAZARDOUS LOCATIONS CLASS I, DIVISION 1, GROUPS A, B, C, D, NON HAZARDOUS LOCATIONS, CLASS I, DIVISION 2, CLASS II, DIVISION 1, GROUPS E, F, G, CLASS III, DIVISION 1, GROUPS A, B, C, D T-Code T4, CLASS I, ZONE 2, GROUP IIC T4 CLASS I, ZONE 0, GROUP IIC MODEL D1033Q 3 + = Supply 24 Vdc 4 - voltage free = Proximity Contact 13 1 + = Out 1 In 1 14 2 Common Channels 1-3 = - + 15 5 = Out 2 In 2 16 6 Common Channels 2-4 = - 9 7 + = Out 3 In 3 10 2 Common Channels 1-3 = - 11 8 + = Out 4 In 4 12 6 Common Channels 2-4 = - MODEL D1033D 3 + = Supply 24 Vdc 4 - voltage free = Proximity Contact 13 1 + = Out 1-A In 1 14 2 Common Channel 1 = - 15 5 + = Out 2-A In 2 16 6 Common Channel 2 = - 7 Out 1-B 2 Common Channel 1 8 Out 2-B 6 Common Channel 2 G.M. International DTS0151-17 Page 2/2