CPC1014N Single-Pole, Normally Open 4-Lead SOP OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description Blocking Voltage 60 V The CPC1014N is a miniature single-pole, normally P open (1-Form-A) solid state relay in a 4-lead SOP Load Current 400 mA / mA rms DC package that employs optically coupled MOSFET On-Resistance (max) 2 technology to provide 1500V of input/output rms LED Current to operate 2 mA isolation. The super efficient MOSFET switches and photovoltaic die use IXYS Integrated Circuits Divisions patented OptoMOS architecture. The optically coupled Features output is controlled by a highly efficient GaAlAs Designed for use in security systems complying infrared LED. with EN50130-4 1500V Input/Output Isolation IXYS Integrated Circuits Divisions state of the art, rms Small 4-Lead SOP Package double-molded vertical construction packaging makes TTL/CMOS Compatible input the CPC1014N one of the worlds smallest relays. It Arc-Free With No Snubbing Circuits offers board space savings of at least 20% over the No EMI/RFI Generation competitors larger 4-lead SOP relay. Immune to radiated EM fields SMD Pick & Place, Wave Solderable Approvals Tape & Reel Version Available UL Recognized Component: File E76270 CSA Certified Component: Certificate 1175739 EN/IEC 60950-1 Certified Component: TUV Certificate B 09 07 49410 004 Applications Security Ordering Information Passive Infrared Detectors (PIR) Data Signalling Part Description Sensor Circuitry CPC1014N 4-Lead SOP (100/tube) Instrumentation CPC1014NTR 4-Lead SOP (2000/reel) Multiplexers Data Acquisition Electronic Switching Pin Configuration I/O Subsystems Meters (Watt-Hour, Water, Gas) 1 4 + Control Load Medical EquipmentPatient/Equipment Isolation Aerospace Industrial Controls 2 3 Control Load Switching Characteristics of Normally Open Devices Form-A I F 90% 10% I LOAD t t on off Pb e3 DS-CPC1014N-R03 1 www.ixysic.comCPC1014N INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 60 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1A Input Power Dissipation 70 mW 1 Total Power Dissipation 400 mW Isolation Voltage, Input to Output 1500 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 3.33 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current 1 Continuous I =2mA I - - 400 mA / mA F L rms DC Peak t <10ms I - - 1 A LPK P 2 On-Resistance I =400mA R -- 2 L ON Off-State Leakage Current V =60V I -- 1 A L P LEAK Switching Speeds Turn-On t - 0.47 2 on I =5mA, V =10V ms F L Turn-Off t - 0.22 1 off Output Capacitance V =50V, f=1MHz C -40 - pF L OUT Input Characteristics 3 Input Control Current to Activate I =400mA I - 0.25 2 mA L F Input Control Current to Deactivate - I 0.1 0.2 - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I - - 10 A R R Common Characteristics Capacitance, Input to Output - - - 1 - pF 1 o o Load current derates linearly from 400mA 25 C to 200mA 80 C. 2 Measurement taken within 1 second of on-time. 3 o For applications requiring high temperature operation (greater than 60 C) a LED drive current of 4mA is recommended. R03 2 www.ixysic.com