CPC1333 Single-Pole Normally Closed 350V, 130mA OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameters Ratings Units Description Peak Blocking Voltage 350 V The CPC1333G is a single-pole, normally closed P (1-Form-B) Solid State Relay with an enhanced input Load Current 130 mA / mA rms DC to output isolation barrier of 5000V . On-Resistance (max) 30 rms The relay output is constructed with efficient Isolation Voltage, Input to Output 5000 V rms MOSFET switches that use IXYS Integrated Circuits patented OptoMOS architecture. The input, a highly efficient infrared LED, controls the optically coupled Features output. 5000V Input/Output Isolation rms 350V Blocking Voltage P Low Drive Power Requirements Approvals Arc-Free With No Snubbing Circuits UL Recognized Component: File E76270 No EMI/RFI Generation EN/IEC 60950-1 Certified Component: Small 4-Pin Package Certificate available on our website Flammability Rating UL 94 V-0 Ordering Information Applications Part Number Description Telephony Switching CPC1333G 4-Pin DIP (100/Tube) Instrumentation CPC1333GR 4-Pin Surface Mount (100/Tube) Multiplexers CPC1333GRTR 4-Pin Surface Mount (1000/Reel) Data Acquisition Electronic Switching I/O Subsystems Pin Configuration Meters (Watt-Hour, Water, Gas) Medical EquipmentPatient/Equipment Isolation 1 4 + Control Security Load Aerospace Industrial Controls 2 3 Control Load Switching Characteristics of Normally Closed Devices Form-B I F I LOAD t t off on DS-CPC1333-R04 1 www.ixysic.comINTEGRATED CIRCUITS DIVISION CPC1333 Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Peak Blocking Voltage 350 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1 A Typical values are characteristic of the device at +25C, 1 Input Power Dissipation 100 mW and are the result of engineering evaluations. They are 2 Total Package Dissipation 550 mW provided for information purposes only, and are not part of Isolation Voltage, Input to Output 5000 V the manufacturing testing requirements. rms ESD Rating, Human Body Model 8 kV Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33mW / C 2 Derate linearly 3mW / C Electrical Characteristics 25C Parameters Conditions Symbol Min Typ Max Units Output Characteristics Load Current Continuous - I - - 130 mA / mA L rms DC Peak t=10ms I - - 350 mA LPK P 1 On-Resistance I =130mA R -25 30 L ON Off-State Leakage Current I =2mA, V =350V I -- 1 A F L LEAK Switching Speeds Turn-On Output (Deactivate) t -- 2 on I =5mA, V =10V ms F L Turn-Off Output (Activate) t -- 3 off Output Capacitance I =2mA, V =50V, f=1MHz C -6 - pF F L OUT Input Characteristics 2 Input Control Current to Activate -I - 0.18 2 mA F Input Control Current to Deactivate I =130mA I 0.1 - - mA L F Input Voltage Drop I =5mA V 0.9 1.26 1.5 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Capacitance, Input to Output V =0V, f=1MHz C -3 - pF IO IO 1 Measurement taken within one second of on-time. 2 For high temperature operation (>60C), IXYS Integrated Circuits recommends a minimum LED drive current of 5mA. Timing Diagram CPC1333G Isolation Test Circuit 1 4 I F Test Conditions: 0 mA Voltage Ramp: 2V/ s 2 3 Test Time: 2 Seconds I Threshold: 50 A 90% LEAK Test Voltage: 6kV I rms L 10% 0 mA 6kV rms t t off on 2 R04 www.ixysic.com