CPC1983YE Normally Open Power SIP Relay INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description Blocking Voltage 600 V P IXYS Integrated Circuits brings OptoMOS Load Current 0.5 A / A rms DC technology, reliability, and compact size to a new On-Resistance (max) 6 family of high power Solid State Relays. Input / Output Isolation 4 kV As part of this family, the CPC1983YE single-pole normally open (1-Form-A) Solid State Power Relay Features is rated for up to 0.5A / 0.5A continuous load DC rms 4000V Input/Output Isolation current. rms Handle Load Currents Up to 0.5A 600V Blocking Voltage The CPC1983YE employs optically coupled MOSFET P Power SIP Package technology to provide 4000V of input to output rms High Reliability isolation. The optically coupled outputs, that use Low Drive Power Requirements patented OptoMOS architecture, are controlled by a Arc-Free With No Snubbing Circuits highly efficient infrared LED. No EMI/RFI Generation Flammability Rating UL 94 V-0 This combination of low on-resistance and high load current handling capability makes this relay suitable for a variety of high performance switching Applications applications. Industrial Controls The suffix signifies an enhanced isolation voltage. Motor Control Robotics Medical EquipmentPatient/Equipment Isolation Approvals Instrumentation UL Recognized Component: File E69938 Multiplexers Data Acquisition Ordering Information Electronic Switching Part Description I/O Subsystems CPC1983YE 4-Pin (8-Pin Body) Power SIP Package (25 per tube) Meters (Watt-Hour, Water, Gas) IC Equipment Home Appliances Switching Characteristics of Normally Open Devices Pin Configuration Form-A I F 90% 10% I LOAD t t on off DS-CPC1983YE-R03 1 www.ixysic.comCPC1983YE INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 600 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1 A 1 Typical values are characteristic of the device at +25C, Input Power Dissipation 150 mW 2 and are the result of engineering evaluations. They are Total Power Dissipation 2400 mW provided for information purposes only, and are not part of 3 Isolation Voltage, Input to Output 4000 V rms the manufacturing testing requirements. ESD Rating, Human Body Model 8 kV Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 20 mW / C 3 UL File 69938 is only rated by UL to 2500V . rms Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current, Continuous I =5mA, Free air I - - 0.5 A / A F L rms DC Peak Load Current I =5mA, t=10ms I - - 3 A F LPK P 1 On-Resistance I =5mA, I =0.5A R - 3.5 6 F L ON Off-State Leakage Current I =0mA, V =600V I -- 1 A F L P LEAK Switching Speeds Turn-On t - 2.2 5 on I =5mA, V =10V ms F L Turn-Off t - 0.15 2 off Output Capacitance I =0mA, 50V, f=1MHz C -41 - pF F OUT Input Characteristics Input Control Current to Activate I =0.5A I - 1.3 5 mA L F Input Control Current to Deactivate - I 0.5 - - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.5 V F F Reverse Input Current V =5V I - - 10 A R R Input/Output Characteristics Capacitance Input/Output V =0V, f=1MHz C -2 - pF IO IO 1 Measurement taken within 1 second of on-time. Thermal Characteristics Parameter Conditions Symbol Min Typ Max Units Thermal Impedance (junction to case) - R - 1.5 - C/W JC 2 R03 www.ixysic.com