LCA100L Single-Pole OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameter Ratings Units Description Blocking Voltage 350 V The LCA100L is a current-limiting, 350V, 120mA, 25, P Load Current 120 mA & mA 1-Form-A relay. It features one of the lowest rms DC on-resistances available in a 350V OptoMOS relay. On-Resistance (max) 25 Approvals Features UL Recognized Component: File E76270 3750V Input/Output Isolation rms CSA Certified Component: Certificate 1172007 Current Limiting EN/IEC 60950 Certified Component: Low Drive Power Requirements (TTL/CMOS TUV Certificate B 09 07 49410 004 Compatible) No Moving Parts High Reliability Ordering Information Arc-Free With No Snubbing Circuits Part Description FCC Compatible LCA100L 6-Pin DIP (50/Tube) VDE Compatible LCA100LS 6-Pin Surface Mount (50/Tube) No EMI/RFI Generation LCA100LSTR 6-Pin Surface Mount (1,000/Reel) Small 6-Pin DIP Package Machine Insertable, Wave Solderable Surface Mount Tape & Reel Version Available Pin Configuration Applications AC/DC Configuration Telecommunications 1 6 + Control Load Telecom Switching 2 5 Tip/Ring Circuits Control Do Not Use Modem Switching (Laptop, Notebook, 3 4 Do Not Use Load Pocket Size) Hook Switch Dial Pulsing DC Only Configuration Ground Start Ringing Injection 1 6 + Control + Load Instrumentation 2 5 Multiplexers Control Load 3 4 Data Acquisition Do Not Use Electronic Switching I/O Subsystems Meters (Watt-Hour, Water, Gas) Medical EquipmentPatient/Equipment Isolation Switching Characteristics of Security Normally Open (Form A) Devices Aerospace Industrial Controls Form-A I F 90% 10% I LOAD t t on off Pb e3 DS-LCA100L-R02 1 www.ixysic.comLCA100L INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 350 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1A 1 Input Power Dissipation 150 mW 2 Total Power Dissipation 800 mW Isolation Voltage, Input to Output 3750 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 6.67 mW / C Electrical Characteristics 25C (Unless Otherwise Noted) Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current 1 AC/DC Con guration, Continuous -I - - 120 mA & mA L rms DC 1 DC Con guration, Continuous -I - - 200 mA L DC 2 On-Resistance AC/DC Con guration I =120mA -- 25 L R ON DC Con guration I =200mA -- 8 L Off-State Leakage Current V =350V I -- 1 A L LEAK Switching Speeds Turn-On t -- 5 ms on I = 5mA, V = 10V F L Turn-Off t -- 5 ms off Output Capacitance 50V, f=1MHz C -35 - pF OUT Load Current Limiting - I 130 170 210 mA CL Input Characteristics Input Control Current to Activate I = 120mA I -- 5 mA L F Input Control Current to Deactivate - I 0.4 0.7 - mA F Input Voltage Drop I = 5mA V 0.9 1.2 1.4 V F F Reverse Input Current V = 5V I - - 10 A R R Common Characteristics Capacitance, Input to Output - C -3 - pF I/O 1 If both poles operate, then the load current must be derated so that the package power dissipation value is not exceeded. 2 Measurement taken within 1 second of on-time. R02 2 www.ixysic.com