LCB716 Single-Pole, Normally Closed OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description Load Voltage 60 V LCB716 is a single-pole, normally closed (1-Form-B) P Load Current 500 mA / mA solid state relay that uses optically coupled relay rms DC On-Resistance (max) 2 technology to provide an enhanced 3750V rms isolation barrier between the input and the output of the relay. The efficient MOSFET output switch uses IXYS Integrated Circuits Division s patented Features OptoMOS architecture. The optically coupled output 3750V Input/Output Isolation rms is controlled by a highly efficient GaAlAs infrared Low Drive Power Requirements LED. (TTL/CMOS Compatible) No Moving Parts Approvals High Reliability Arc-Free With No Snubbing Circuits UL Recognized Component: File E76270 No EMI/RFI Generation CSA Certified Component: Certificate 1175739 Small 6-Pin Package EN/IEC 60950-1 Certified Component: Machine Insertable, Wave Solderable TUV Certificate B 09 07 49410 006 Tape & Reel, Surface Mount Version Available Ordering Information Part Description Applications LCB716 6-Pin DIP (50/Tube) Sensor Circuitry LCB716S 6-Pin Surface Mount (50/Tube) Instrumentation LCB716STR 6-Pin Surface Mount (1000/Reel) Multiplexers Data Acquisition Electronic Switching Pin Configuration I/O Subsystems AC/DC Configuration Meters (gas, oil, electric and water) 1 6 Medical Equipment-Patient/Equipment Isolation + Control Load Security 2 5 Control Do Not Use Aerospace 3 4 Do Not Use Load Industrial Controls DC-Only Configuration 1 6 + Control + Load 2 5 Control Load 3 4 Do Not Use Switching Characteristics of Normally Closed Devices Form-B I F I LOAD 90% 10% t t off on Pb e3 DS-LCB716-R03 1 www.ixysic.comLCB716 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 60 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. 1A Peak (10ms) 1 Input Power Dissipation 100 mW 2 Total Power Dissipation 800 mW Isolation Voltage, Input to Output 3750 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 6.67 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current - - - 500 mA / mA AC/DC Configuration, Continuous rms DC I L DC Configuration, Continuous - - - 1000 mA DC Peak t < 10ms I - - 1.2 A LPK P On-Resistance AC/DC Configuration I =500mA - 1.63 2 L R ON DC Configuration I =1000mA - 0.4 0.5 L Off-State Leakage Current I =2mA, V =60V I -- 1 A F L LEAK Output Capacitance I =2mA, V =50V, f=1MHz C - 280 - pF F L OUT Switching Speeds t - 0.58 3 Turn-On on I =5mA, V =10V ms F L Turn-Off t - 0.76 3 off Input Characteristics Input Control Current to Activate I =500mA I -- 2 mA L F Input Control Current to Deactivate - I 0.1 - - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Capacitance, Input to Output - C -3- pF I/O R03 2 www.ixysic.com