PAA193 Dual Single-Pole, Normally Open OptoMOS Relays INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description Load Voltage 600 V The PAA193 is a dual normally open (1-Form-A) solid P state relay that uses optically coupled relay technology Load Current 100 mA / mA rms DC to provide an enhanced 5000V input to output On-Resistance (max) 50 rms isolation barrier. The efficient MOSFET switches use IXYS IC Division s patented OptoMOS architecture. Highly efficient GaAIAs infrared LEDs provide the Features optically coupled control. 5000V Input/Output Isolation rms Low Drive Power Requirements (TTL/CMOS Dual OptoMOS relays provide a more compact design Compatible) solution than discrete single-pole relays in a variety No Moving Parts of applications. The dual relays save board space by High Reliability incorporating two relays in a single 8-pin package. Arc-Free With No Snubbing Circuits No EMI/RFI Generation Small 8-Pin Package Approvals Machine Insertable, Wave Solderable UL Recognized Component: File E76270 Surface Mount Tape & Reel Version Available CSA Certified Component: Certificate 1175739 EN/IEC 60950-1 Certified Component: TUV Certificate B 09 07 49410 004 Applications Instrumentation Multiplexers Ordering Information Data Acquisition Electronic Switching Part Description I/O Subsystems PAA193 8-Lead DIP (50/tube) Meters (Watt-Hour, Water, Gas) PAA193S 8-Lead Surface Mount (50/tube) Medical Equipment-Patient/Equipment Isolation PAA193STR 8-Lead Surface Mount (1000/Reel) Security Aerospace Industrial Controls Pin Configuration 1 8 + Control - Switch 1 Load - Switch 1 2 7 - Control - Switch 1 Load - Switch 1 3 6 + Control - Switch 2 Load - Switch 2 4 5 - Control - Switch 2 Load - Switch 2 Switching Characteristics of Normally Open Devices Form-A I F 90% 10% I LOAD t t on off Pb e3 DS-PAA193-R03 1 www.ixysic.comPAA193 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 600 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1 A 1 Input Power Dissipation 150 mW 2 Total Power Dissipation 800 mW Isolation Voltage, Input to Output 5000 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 6.67 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current Continuous * - I - - 100 mA / mA L rms DC Peak t=10ms I - - 350 mA LPK P On-Resistance I=100mA R -- 50 L ON Off-State Leakage Current V =600V I - - 10 A L P LEAK Switching Speeds Turn-On t -- 5 on I =5mA, V =10V ms F L Turn-Off t -- 5 off Output Capacitance V =50V, f=1MHz C -50 - pF L OUT Input Characteristics Input Control Current to Activate I =100mA I -- 5 mA L F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I - - 10 A R R Common Characteristics Capacitance, Input to Output - C -3 - pF I/O *NOTE: If both poles operate simultaneously, then load current must be derated in order not to exceed the package power dissipation value. R03 2 www.ixysic.com