PLA193 600V, 100mA Single-Pole, Normally Open Relay INTEGRATED CIRCUITS DIVISION Parameters Ratings Units Description Blocking Voltage 600 V P IXYS Integrated Circuits PLA193 is a single-pole, Load Current 100 mA / mA normally open (1-Form-A) solid state relay that rms DC On-Resistance (max) 50 provides 5000V of input to output isolation. rms LED Current to Operate 5 mA In addition to all the features and benefits of the PLA193, the PLA193E uses double-molded vertical construction to meet the partial discharge demands of DIN EN 60747-5-5 (Previously VDE 0884). Features PLA193E is 100% Tested for Partial Discharge: All versions of the PLA193 can be used to replace DIN EN 60747-5-5 mechanical relays, while offering the superior 5000V Input/Output Isolation reliability associated with semiconductor devices. rms Low Drive Power Requirements Employing the patented OptoMOS architecture, the Greater Reliability than Electromechanical Relays highly efficient infrared LED controls the optically No EMI/RFI Generation coupled outputs. Because they have no moving parts, Small 6-Pin Package they offer bounce-free switching in more compact Flammability Rating UL 94 V-0 surface mount or thru-hole packages. Approvals Applications Instrumentation UL Recognized Component: File E76270 Multiplexers CSA Certified Component: Certificate 1175739 Data Acquisition TUV EN 62368-1: Certificate B 082667 0008 Electronic Switching DIN EN 60747-5-5 Certified Suffix Only) I/O Subsystems VDE Certificate 40036603 Meters (Watt-Hour, Water, Gas) Medical EquipmentPatient/Equipment Isolation Ordering Information Security Part Description Industrial Controls PLA193E 6-Pin DIP (50/Tube) PLA193ES 6-Pin Surface Mount (50/Tube) Pin Configuration PLA193ESTR 6-Pin Surface Mount (1000/Reel) PLA193 6-Pin DIP (50/Tube) AC/DC Configuration PLA193S 6-Pin Surface Mount (50/Tube) 1 6 + Control Load PLA193STR 6-Pin Surface Mount (1000/Reel) 2 5 - Control Do Not Use 3 4 NC Load Switching Characteristics of Normally Open Devices DC Only Configuration 1 6 Form-A + Control + Load 2 5 - Control - Load 3 4 I F NC 90% 10% I LOAD t t on off DS-PLA193-R09 1 www.ixysic.comPLA193 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings ( 25C Unless Otherwise Noted) Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to the Blocking Voltage 600 V P device. Functional operation of the device at conditions beyond Reverse Input Voltage 5 V those indicated in the operational sections of this data sheet is Input Control Current 50 mA not implied. Peak (10ms) 1 A 1 Input Power Dissipation 150 mW 2 Typical values are characteristic of the device at +25C, and Total Package Dissipation 800 mW are the result of engineering evaluations. They are provided for ESD Rating, Human Body Model 8 kV information purposes only, and are not part of the manufacturing Isolation Voltage, Input to Output (60 Seconds) 5000 V rms testing requirements. Operational Temperature, Ambient -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate output power linearly 6.67 mW / C Electrical Characteristics ( 25C Unless Otherwise Noted) Parameters Conditions Symbol Min Typ Max Units Output Characteristics Blocking Voltage I =1AV 600 - - V L DRM P Load Current Continuous, AC/DC Configuration - - 100 mA / mA rms DC -I L Continuous, DC-Only Configuration - - 190 mA DC Peak t=10ms I - - 350 mA LPK P 1 On-Resistance AC/DC Configuration I =5mA, I =100mA -25 50 F L R ON DC-Only Configuration I =5mA, I =190mA - 10 18 F L Off-State Leakage Current I =0V, V =600V I -- 1 A F L LEAK Switching Speeds Turn-On t - 0.6 5 ms on I =5mA, V =10V F L Turn-Off t - 0.3 5 ms off Output Capacitance I =0mA, V =50V, f=1MHz C -5 - pF F L OUT Input Characteristics Input Control Current to Activate I =100mA I - 0.45 5 mA L F Input Control Current to Deactivate - I 0.3 0.44 - mA F Input Voltage Drop I =5mA V 0.9 1.36 1.5 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Input to Output Capacitance V =0V, f=1MHz C -3 - pF IO IO 1 Measurement taken within one second of on-time. PLA193E Safety and Insulation Ratings Parameters Conditions Symbol Min Max Units Pollution Degree 2 according to DIN VDE 0109 - ---- Highest Allowable Over-Voltage Transient Voltage V 7071 - V IOTM P Maximum Working Insulation Voltage Recurring Voltage V 1000 - V IORM P Partial Discharge Test Voltage DIN EN 60747-5-5 Method B V - 1875 V PR P Isolation Test Voltage - V - 5000 V ISO rms Creepage Distance - - 7.6 - mm Clearance Distance - - 7.6 - mm 2 R09 www.ixysic.com