MAPS-010164 Digital Phase Shifter Rev. V3 6-Bit, 2.3 - 3.8 GHz Features Functional Schematic 6 Bit Digital Phase Shifter 360 Coverage with LSB = 5.6 Integrated CMOS Driver Serial or Parallel Control Low DC Power Consumption P/S Minimal Attenuation Variation over Phase Shift Range 50 Impedance EAR99 Lead-Free 4 mm 24-Lead PQFN Package RoHS* Compliant Description The MAPS-010164 is a GaAs pHEMT 6-bit digital phase shifter with an integrated CMOS driver in a 4 mm PQFN plastic surface mount package. Step size is 5.6 providing phase shift from 0 to 360 in 5.6 steps. This design has been optimized to minimize variation in attenuation over the phase shift 2 Pin Configuration range. Pin No. Function Pin No. Function The MAPS-010164 is ideally suited for use where 1 VEE 13 GND high phase accuracy with minimum loss variation over the phase shift range are required. The 4 mm 2 P/S 14 RF OUT PQFN package provides a smaller footprint than is 3 GND 15 GND typically available for a digital phase shifter with an internal driver. Typical applications include 4 GND 16 GND communications antennas and phased array radars. 5 RF IN 17 SER OUT 6 GND 18 VCC 1 7 GND 19 D6 Ordering Information Part Number Package 8 GND 20 D5 9 GND 21 D4 MAPS-010164-TR0500 500 piece reel 10 GND 22 D3 or LE MAPS-010164-001SMB Sample Test Board 11 GND 23 D2 or CLK 1. Reference Application Note M513 for reel size information. 12 GND 24 D1 or SER IN 2. The exposed pad centered on the package bottom must be connected to RF and DC ground. * Restrictions on Hazardous Substances, European Union Directive 2002/95/EC. 11 1 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: MAPS-010164 Digital Phase Shifter Rev. V3 6-Bit, 2.3 - 3.8 GHz Electrical Specifications: Freq. = 2.3 - 3.8 GHz, T = 25C, Z = 50 , V = +5.0 V, V = -5.0 V A 0 CC EE Parameter Test Conditions Units Min. Typ. Max. 3 Operating Power 2.3 - 3.8 GHz dBm +25 Insertion Loss Any Phase State dB 3.2 4.5 (Any Phase State) Attenuation Variation Across All Phase States dB 0.6 All Values Relative to Insertion Loss at 4 RMS Attenuation Error dB 0.3 Reference Phase 4 RMS Phase Error All Values Relative to Reference Phase deg 3 5.6 Degree Bit 1.5 11.2 Degree Bit 1.5 22.5 Degree Bit 2 Phase Accuracy 45 Degree Bit deg 2 Relative to Reference Loss State 90 Degree Bit 3 180 Degree Bit 4 Sum of All Bits - 5 RF IN 1.3:1 VSWR Ratio RF OUT 1.3:1 1 dB Compression Reference State dBm 25 Input IP3 Two-tone inputs up to +5 dBm dBm 45 T , T 10% to 90% RF, 90% to 10% RF ns 50 RISE FALL V 3.0 5.5 CC V V -5.5 -5.0 -3.0 EE V LOW-level input voltage 0.0 0.3 x V IL CC V V HIGH-level input voltage 0.7 x V V IH CC CC l (Input Control Current) V = V or GND A 1 IN IN CC V For serial out I = -100 A V - 0.2 OH OH CC V V For serial out I = 100 A 0.2 OL OL Icc Vcntrl = V or GND A 2.5 CC (Quiescent Supply Current) V min to max EE I mA -1.0 -0.1 EE Vin = V or V IL IH 3. Maximum operating power is the maximum power where the specifications are guaranteed. 4. RMS is calculated across all 63 amplitude or phase states relative to the amplitude or phase in the 0 phase state at a given frequency. 22 2 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: