55W Single Output with 5V,4A DC-DC Converter ADS-55 series Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 45KHz 2 years warranty SPECIFICATION MODEL ADS-5512 ADS-5524 OUTPUT NUMBER CH1 CH2 CH1 CH2 DC VOLTAGE 12V 5V 24V 5V RATED CURRENT 3A 3A 2A 2A CURRENT RANGE 0 ~ 4A 0 ~ 4A 0 ~ 2.5A 0 ~ 4A RATED POWER 51W 58W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 100mVp-p 100mVp-p OUTPUT VOLTAGE ADJ. RANGE CH1:10.8 ~ 13.2V CH1:21.6 ~ 26.4V VOLTAGE TOLERANCE Note.3 1.0% 3.0% 1.0% 3.0% LINE REGULATION 0.5% 0.5% 1.0% 0.5% LOAD REGULATION 0.5% 0.5% 1.0% 0.5% SETUP, RISE TIME 1400ms, 50ms/230VAC 3300ms, 50ms/115VAC at full load HOLD UP TIME (Typ.) 80ms/230VAC 16ms/115VAC at full load VOLTAGE RANGE 88 ~ 264VAC 124 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 76% 79% INPUT AC CURRENT (Typ.) 1.6A/115VAC 1A/230VAC INRUSH CURRENT (Typ.) COLD START 20A/115VAC 40A/230VAC LEAKAGE CURRENT <1mA / 240VAC 105 ~ 150% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION CH1:13.8 ~ 16.2V CH1:27.6 ~ 32.4V OVER VOLTAGE Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0~50 ) on CH1 output VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMC (Note 4) EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A MTBF 276.3K hrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSION 159*97*38mm (L*W*H) 0.57Kg 24pcs/13.7Kg/0.75CUFT PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. NOTE 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on 3.5 3-M3 55W Single Output with 5V,4A DC-DC Converter ADS-55 series Mechanical Specification Case No. 901 Unit:mm 4.5 152.5 1 2 3 4 5 6 7 8 4.5 24 78 159 6.5 150 Terminal Pin No. Assignment : Pin No. Assignment Pin No. Assignment 1 AC/L 5 DC OUTPUT +V 2 AC/N 6 NC 3 FG 8 DC/DC OUTPUT +5V 4,7 DC OUTPUT COM 22 117 Block Diagram fosc : 45KHz SWITCHING +5V REGULATOR RECTIFIERS RECTIFIERS EMI POWER +V I/P & & SWITCHING FILTER COM FILTER FILTER FG PWM DETECTION O.L.P. CONTROL CIRCUIT Derating Curve Static Characteristics (5512) 12 5.2 300 100 +12V 250 11 5.0 With 18.2CFM min.(10cm) +5V 80 10 4.8 200 70 9 4.6 150 60 50 NO FAN 100 8 4.4 40 7 4.2 +12V 50 20 25 6 4.0 +5V -10 0 10 20 30 40 50 60 (HORIZONTAL) 60 80 100 120 140 160 180 200 220 240 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:ADS-55-SPEC 2011-06-16 3.5 2-M3 LOAD (%) 6.5 8.25 9 18.5 65 OUTPUT VOLTAGE (V) 18 9 3.5 3.5 28.5 84.5 7 38 97 OUTPUT RIPPLE (mVp-p)