16.8 ~ 30W AC-DC Power Adaptor with Charger Function GC30U series 6 - Users Manual Video 7 8 % 9 9 : 7 8 :8 : < 6 = 56. 3 8 : II 3 83 : 3 > 8 % : = 6 - = < 4 < 4 < 4 , 6 * - < < < < 6 3 SPECIFICATION ORDER NO. GC30U-0P1J GC30U-1P1J GC30U-11P1J GC30U-2P1J GC30U-4P1J GC30U-5P1J GC30U-6P1J SAFETY MODEL NO. GC30U-0 GC30U-1 GC30U-11 GC30U-2 GC30U-4 GC30U-5 GC30U-6 DC VOLTAGE SET AT Note.3 4.2V 5.6V 7.2V 8.4V 14.3V 16.8V 28.6V RATED CURRENT 4A 3.99A 3A 3A 2.09A 1.6A 1.04A CURRENT RANGE 0 ~ 4A 0 ~ 3.99A 0 ~ 3A 0 ~3A 0 ~ 2.09A 0 ~ 1.6A 0 ~ 1.04A RATED POWER 16.8W 22.38W 21.6W 25.2W 30W 27W 30W OUTPUT RIPPLE & NOISE (max.) Note.4 50mVp-p 50mVp-p 80mVp-p 80mVp-p 100mVp-p 100mVp-p 150mVp-p CHARGING VOLTAGE RANGE Note.5 3.6 ~ 4.4V 5 ~ 5.8V 6.5 ~ 7.5V 7.7 ~ 8.6V 13.5 ~ 14.5V 16 ~ 17V 27.1 ~ 28.8V LINE REGULATION Note.6 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LED INDICATOR Green LED ON < 100mA, Red LED ON > 250mA SETUP, RISE, HOLD UP TIME 200ms, 50ms, 16ms at full load VOLTAGE RANGE 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 55% 70% 74% 76% 78% 78% 80% INPUT AC CURRENT 0.7A / 100VAC 0.35A/ 230VAC INRUSH CURRENT (max.) 40A / 230VAC LEAKAGE CURRENT(max.) 0.25mA / 240VAC 90 ~ 110% Constant current mode and over 300% pulsing mode OVERLOAD Protection type : Constant current limiting, recovers automatically after fault condition is removed 110 ~ 135% rated output voltage PROTECTION OVER VOLTAGE Protection type : Clamp by zener diode IC1 Tj > 130 OVER TEMPERATURE Protection type : Shut down o/p voltage, recovers automatically after temperature goes down 0 ~ +50 (Refer toDerating Curv) WORKING TEMP. 20% ~ 90% RH non-condensing WORKING HUMIDITY -20 ~ +85, 10 ~ 95% RH ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 0.03% / (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL62368-1, CSA22.2, EAC TP TC 004 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH EMC Compliance to FCC part 15 Class B, EAC TP TC 020 EMC EMISSION EMC IMMUNITY Compliance to EAC TP TC 020 DIMENSION 108*67*36mm (L*W*H) OTHERS 405g 36pcs / 16.5kg / CARTON PACKING PLUG Standard type P1J: 2.1* 5.5 * 11mm, tuning fork type center positive for stock Other type available by customer requested CONNECTOR CABLE Standard type 18Awg UL1185 6ft and 4ft for 4.2V~8.4V output only for stock Other type available by customer requested NOTE % % & ( )* + , - . / ( 0 ) / *1 2 3 3 / 0& 4 ( ( 5 3 , 6 % 33.5 42 16.8 ~ 30W AC-DC Power Adaptor with Charger Function GC30U series Mechanical Specification Unit:mm 12.7 18 69.9 C3 R1 NAME PLATE RUBBER FOOTx4 UL1185 16AWG 123050 for 4.2V~8.4V 106 UL1185 18AWG 183050 for 14.3~28.6V 11 ID 2.1 x OD 5.5 POWER LED 108 Charging Curve LED Display Plug Assignment (V,I) Standard plug: P1J (option) LED Status Load Condition Stage 1 Stage 2 Constant Current Area Constant Voltage Area Red Charging P1J V Green Float Charging P/N OUTPUT Vmax=Rated Voltage CENTER + Battery Voltage Imax=Rated Current I Float Charging TIME Suitable for lead-acid batteries (flooded,Gel and AGM) and Li-ion batteries (lithium iron and lithium manganese) Derating Curve Static Characteristics 100 100 80 70 60 0 10 20 30 40 50 05060 70 80 90 100 264 Ta () INPUT VOLTAGE File Name:GC30U-SPEC 2021-12-08 61050 LOAD (%) 6020 17.2 35.7 45 LOAD (%) 67