150W Single Output with PFC Function HRP-150 series Users Manual ) % & ( & ) * + & + + , , . / ,, , / Bauart gepruft Sicherheit egelma ge od os be wac g www.tuv.com ID 2000000000 UL62368-1 BS EN/EN62368-1 TPTC004 IEC62368-1 SPECIFICATION MODEL HRP-150-3.3 HRP-150-5 HRP-150-7.5 HRP-150-12 HRP-150-15 HRP-150-24 HRP-150-36 HRP-150-48 DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 36V 48V RATED CURRENT 30A 26A 20A 13A 10A 6.5A 4.3A 3.3A CURRENT RANGE 0 ~ 30A 0 ~ 26A 0 ~ 20A 0 ~ 13A 0 ~ 10A 0 ~ 6.5A 0 ~ 4.3A 0 ~ 3.3A RATED POWER 99W 130W 150W 156W 150W 156W 154.8W 158.4W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p OUTPUT VOLTAGE ADJ. RANGE 2.8 ~ 3.8V 4.3 ~ 5.8V 6.8 ~ 9V 10.2 ~ 13.8V 13.5 ~ 18V 21.6 ~ 28.8V 28.8 ~ 39.6V 40.8 ~ 55.2V VOLTAGE TOLERANCE Note.3 2.5% 2.5% 2.5% 1.5% 1.5% 1.5% 1.5% 1.5% LINE REGULATION 0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2% LOAD REGULATION 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 3000ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC at full load VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC PF>0.99/115VAC at full load INPUT EFFICIENCY (Typ.) 78.5% 85% 87% 88% 88% 88% 89% 89% AC CURRENT (Typ.) 1.7A/115VAC 0.9A/230VAC INRUSH CURRENT (Typ.) 35A/115VAC 70A/230VAC LEAKAGE CURRENT <1mA / 240VAC 105 ~ 135% rated output power OVERLOAD Protection type : Constant current limiting, recovers automatically after fault condition is removed 3.96 ~ 4.62V 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 57.6 ~ 67.2V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down -40 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY -50 ~ +85, 10 ~ 95% RH ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 0.04%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC (Note 4) EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55024,BS EN/EN61000-6-2,heavy industry level,criteria A,EAC TP TC 020 238.8K hrs min. MIL-HDBK-217F (25) MTBF OTHERS DIMENSION 159*97*38mm (L*W*H) PACKING 0.61Kg 24pcs/15.6Kg/0.9CUFT . , 0+1 , & , & 2 ( & & & 2 ,- , NOTE 2 3 4 , & 2 5 6 - &/ & .27 / & / , & / . 4 89 1 ) & & & 8 1 / & & , / / - & : , 5 - < & , ,,= ,, , / .,, > 1 : , , - , & , 5 & & / , 5 5A , / B (as available on 6 4 2 5 3 1 3.5 150W Single Output with PFC Function HRP-150 series Mechanical Specification Case No.901I Unit:mm 152.5 1 2 3 4 5 6 7 CN100 SVR1 Terminal Pin No. Assignment : 4.5 Pin No. Assignment Pin No. Assignment 24 78 1 AC/L 4,5 DC OUTPUT -V 2 AC/N 6,7 DC OUTPUT +V 159 3 FG 6.5 150 Connector Pin No. Assignment (CN100) : HRS DF11-6DP-2DSA or equivalent 10 max. Pin No. Assignment Mating Housing Terminal 1 -S 6-M3(Both Sides) L=6 HRS DF11-6DS HRS DF11-**SC 2 +S or equivalent or equivalent 3~6 NC 22 117 Block Diagram PWM fosc :100KHz(3.3~7.5V) 70KHz(12~48V) +S ACTIVE RECTIFIERS RECTIFIERS EMI +V INRUSH POWER I/P & & FILTER CURRENT SWITCHING -V PFC FILTER LIMITING -S DETECTION O.L.P. O.T.P. CIRCUIT FG O.T.P. PFC PWM CONTROL CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage 100 100 Without Cover 90 80 80 70 60 With Cover 60 40 50 20 40 -40 0 1020304050 60 70 (HORIZONTAL) 85 100 125 135 155 264 AMBIENT TEMPERATURE () INPUT VOLTAGE (V) 60Hz File Name:HRP-150-SPEC 2021-09-15 3.5 2-M3 L=4 LOAD (%) 8.2 9.5 9 LOAD(%) 18.5 65 I I 18 9 3.5 3.5 28.5 84.5 7 38 97