150W Single Output with PFC Function L PP-150 series Bauar t gep r u f t S i c h e r h e i t e g e l m a ge o d o s b e w a c g w w w . t u v . c o m ID 2000000000 SPECIFICATION MODEL LPP-150-3.3 LPP-150-5 LPP-150-7.5 LPP-150-12 LPP-150-13.5 LPP-150-15 LPP-150-24 LPP-150-27 LPP-150-48 DC VOLTAGE 3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V RATED CURRENT 30A 30A 20A 12.5A 11.2A 10A 6.3A 5.6A 3.2A CURRENT RANGE 0 ~ 30A 0 ~ 30A 0 ~ 20A 0 ~ 12.5A 0 ~ 11.2A 0 ~ 10A 0 ~ 6.3A 0 ~ 5.6A 0 ~ 3.2A RATED POWER 99W 150W 150W 150W 151.2W 150W 151.2W 151.2W 153.6W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p OUTPUT VOLTAGE ADJ. RANGE 3.14 ~ 3.63V 4.75 ~ 5.5V 7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V VOLTAGE TOLERANCE Note.3 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% SETUP, RISE TIME 600ms, 30ms at full load HOLD UP TIME (Typ.) 30ms at full load VOLTAGE RANGE 85 ~ 264VAC 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR PF0.96/230VAC PF0.97/115VAC at full load INPUT EFFICIENCY(Typ.) 70% 76% 80% 82% 83% 83% 85% 85% 85% AC CURRENT (Typ.) 2.5A/115VAC 1.2A/230VAC INRUSH CURRENT (Typ.) COLD START 55A/230VAC LEAKAGE CURRENT <3.5mA / 240VAC 105 ~ 150% rated output power OVERLOAD Protection type : Constant current limiting, recovers automatically after fault condition is removed PROTECTION 3.63 ~ 4.45V 5.5 ~ 6.75V 8.25 ~ 10.1V 13.2 ~ 16.2V 14.85 ~ 18.2V 16.5~ 20.25V 26.4 ~ 32.4V 29.7 ~ 36.5V 52.8 ~ 64.8V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover WORKING TEMP. -10 ~ +60 with cooling FAN (Refer toDerating Curv) WORKING HUMIDITY 20 ~ 90% RH non-condensing -20 ~ +85, 10 ~ 95% RH ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 0.05%/ (0 ~ 50) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes VIBRATION SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC (Note 4) EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A, EAC TP TC 020 MTBF 191.8Khrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 222*75*41mm (L*W*H) 0.62Kg 24pcs/16.6Kg/1.63CUFT PACKING NOTE (as available on 4-3.8 150W Single Output with PFC Function L PP-150 series Mechanical Specification Unit:mm 222 212 5 CN1 CN2 5 1 4 3 2 1 FAN 18CFM 12 111 +V ADJ. AC Input Connector (CN1) : JST B5P-VH or equivalent DC Output Connector (CN2) : JST B6P-VH*2 or equivalent Pin No. Assignment Mating Housing Terminal Pin No. Assignment Mating Housing Terminal 1 AC/L 1~6 -V JST VHR JST SVH-21T-P1.1 2,4 No Pin JST VHR JST SVH-21T-P1.1 7~12 +V or equivalent or equivalent or equivalent or equivalent 3 AC/N : Grounding Required 5 FG CN1:Pin 5 is safety ground Block Diagram PFC fosc : 67KHz PWM fosc : 134KHz EMI FILTER RECTIFIERS POWER PFC +V I/P & & SWITCHING CIRCUIT -V RECTIFIERS FILTER COSTANT CURRENT LIMITING & FG O.L.P. DETECTION CIRCUIT PWM & PFC ACTIVE CONTROL START O.V.P. CIRCUIT Derating Curve Output Derating VS Input Voltage 100 With 18CFM FAN 100 90 80 80 70 60 With NO FAN 3.3V ~ 7.5V Under 100VAC With No FAN 60 Must derating to 60% load 40 50 20 40 -10 0 10 20 30 40 50 60 70 (HORIZONTAL) 85 100 115 135 155 230 264 AMBIENT TEMPERATURE () INPUT VOLTAGE (V) 60Hz File Name:LPP-150-SPEC 2021-07-05 LOAD (%) 75 41 3 max. 65 5 AC FUSE F5A/250V LOAD (%) 15cm