1000 ~ 3000W Front End Power System RCP se rie s Features : Universal AC input / Full range Built-in 5V/0.3A auxiliary power Built-in active PFC function, PF>0.96 Protections: Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC fan with fan speed control Low profile:1U height Active current sharing up to 3000W (3 units)in 19 rack, 3 racks max. can be operated in parallel (up to 8 units) (Note.7) Remote control for single unit Built-in remote sense function Output voltage trimming function Hot-swap operation 2 Optional I C serial data bus AC OK & DC OK signal Internal ORing diode 3 years warranty SELECTION GUIDE Single Unit: RCP-1000- 12 - C 2 C: With I C Interface 2 -: Without I C Interface Output Voltage I: AC Inlet(IEC320-C14) Rack: RCP-1U I T: Terminal Block I 12 C Whole System: RCP-3K1U - - 2 C: With I C Interface 2 -: Without I C Interface Output Voltage I: AC Inlet(IEC320-C14) T: Terminal Block SPECIFICATION - Single Unit MODEL RCP-1000-12 RCP-1000-24 RCP-1000-48 DC VOLTAGE 12V 24V 48V RATED CURRENT 60A 40A 21A CURRENT RANGE 0 ~ 60A 0 ~ 40A 0 ~ 21A RATED POWER 720W 960W 1008W RIPPLE & NOISE (max.) Note.2 150mVp-p 200mVp-p 300mVp-p OUTPUT VOLTAGE ADJ. RANGE 11.6 ~ 12.4V 23.2 ~ 24.8V 46.3 ~ 49.7V VOLTAGE TOLERANCE Note.3 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% LOAD REGULATION 0.5% 0.5% 0.5% SETUP, RISE TIME 1000ms, 60ms/230VAC at full load HOLD UP TIME (Typ.) 16ms/230VAC at full load VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 81% 87% 89% INPUT 8.5A/115VAC 4.5A/230VAC 10.5A/115VAC 5.5A/230VAC 11A/115VAC 5.5A/230VAC AC CURRENT (Typ.) INRUSH CURRENT (Typ.) COLD START 50A LEAKAGE CURRENT <1.1mA / 230VAC 105 ~ 125% rated output power OVERLOAD Protection type : Constant current limiting, recovers automatically after fault condition is removed 13.2 ~ 16.2V 26.4 ~ 32.4V 52.8 ~ 64.8V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, recovers automatically after temperature goes down OVER TEMPERATURE File Name:RCP series-SPEC 2015-02-111000 ~ 3000W Front End Power System RCP se rie s MODEL RCP-1000-12 RCP-1000-24 RCP-1000-48 5V 0.3A AUXILIARY POWER REMOTE ON/OFF CONTROL By electrical signal or dry contact ON:short OFF:open Compensate voltage drop on the load wiring up to 0.5V REMOTE SENSE FUNCTION DC OK SIGNAL The TTL signal out, refer to function manual AC FAIL SIGNAL The TTL signal out, refer to function manual Adjustment of output voltage, possible between 90 ~ 110% of rated output OUTPUT VOLTAGE TRIM OVER TEMP WARNING Logic Hig for over temperature warning, refer to function manual WORKING TEMP. -20 ~ +60 (Refer toDerating Curv) 20 ~ 90% RH non-condensing WORKING HUMIDITY STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH ENVIRONMENT TEMP. COEFFICIENT 0.02%/ (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.7KVDC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC (Note 4) EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A MTBF 43.4K hrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSION 295*127*41mm (L*W*H) PACKING 1.93Kg 6pcs/12.6Kg/1.04CUFT SPECIFICATION - Rack System MODEL RCP-3K1U -12 RCP-3K1U -24 RCP-3K1U -48 MODULE RCP-1000-12 RCP-1000-24 RCP-1000-48 RACK RCP-1UI or RCP-1UT OUTPUT VOLTAGE 12V 24V 48V OUTPUT MAX. OUTPUT CURRENT 180A 120A 63A MAX. OUTPUT POWER Note.6 2160W 2880W 3024W VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz INPUT 8.5A/115VAC 4.5A/230VAC 10.5A/115VAC 5.5A/230VAC 11A/115VAC 5.5A/230VAC AC CURRENT (Typ.)FOR EACH UNIT LEAKAGE CURRENT <3.5mA / 230VAC 5V 0.3A AUXILIARY POWER By electrical signal or dry contact ON:short OFF:open REMOTE ON/OFF CONTROL Compensate voltage drop on the load wiring up to 0.5V.Local Sensshould be connected in order to get the correct output voltage if theRemote Sensis not used REMOTE SENSE DC OK SIGNAL The TTL signal out, refer to function manual FUNCTION The TTL signal out, refer to function manual AC FAIL SIGNAL OUTPUT VOLTAGE TRIM Adjustment of output voltage, possible between 90 ~ 110% of rated output OVER TEMP WARNING Logic Hig for over temperature warning, refer to function manual -20 ~ +60 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH ENVIRONMENT TEMP. COEFFICIENT 0.02%/ (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.7KVDC WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 (Note 4) EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A DIMENSION Rack 483.6*350.8*44(L*W*H) OTHERS PACKING 13.2Kg 1pcs/13.2Kg/2.67CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. NOTE 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on