G3VM-21LR11 MOS FET Relays * The Worlds Smallest SSOP. MOS FET Relays That Switch Currents Up to 0.9 A with SSOP. Load voltage of 20 V. * As of August 2014 Survey by OMRON RoHS compliant Note: The actual product is marked differently from the image shown here. Application Examples Terminal Arrangement/Internal Connections Semiconductor test equipment Test & Measurement equipment Model name 416 Communication equipment OMRON mark Data loggers 612 LOT.No. Note: The actual product is marked differently from the image shown here. List of Models Minimum package quantity Load voltage Package type Contact form Terminals Model (peak value) * Number per tape and reel G3VM-21LR11 - 1a SSOP4 Surface-mounting Terminals 20 V (SPST-NO) G3VM-21LR11 (TR05) 500 Note: Ask your OMRON representative for orders under 500 pcs. We can supply products with the tape already cut. Tape-cut SSOPs are packaged without humidity resistance. Use manual soldering to mount them. Refer to common precautions. * The AC peak and DC value are given for the load voltage. Absolute Maximum Ratings (Ta = 25 C) Item Symbol Rating Unit Measurement conditions LED forward current IF 50 mA LED forward current reduction rate IF/C 0.5 mA/C Ta 25 C LED reverse voltage VR 5 V Connection temperature TJ 125 C Load voltage (AC peak/DC) VOFF 20 V Continuous load current (AC peak/DC) IO 900 mA ON current reduction rate IO/C 12 mA/C Ta 50 C Pulse ON current Iop 2.7 A t = 100 ms, Duty = 1/10 Connection temperature TJ 125 C Dielectric strength between VI-O 1500 Vrms AC for 1 min I/O (See note 1.) Note: 1. The dielectric strength between the input and Ambient operating temperature Ta 20 to +85 C With no icing or condensation output was checked by applying voltage Ambient storage temperature Tstg 40 to +125 C With no icing or condensation between all pins as a group on the LED side and Soldering temperature - 260 C 10 s all pins as a group on the light-receiving side. Electrical Characteristics (Ta = 25 C) Item Symbol Minimum Typical Maximum Unit Measurement conditions LED forward voltage VF 1.0 1.15 1.3 V IF = 10 mA Note: 2. Turn-ON and Turn-OFF Times Reverse current IR - - 10 A VR = 5 V IF 1 4 RL Capacity between terminals CT - 15 - pF V = 0, f = 1 MHz VDD VOUT Trigger LED forward current IFT - - 3 mA IO = 100 mA 2 3 Turn-OFF LED forward current IFC 0.1 - - mA IOFF = 10 A Maximum resistance with output ON RON - 0.18 0.22 IF = 5 mA, IO = 900 mA, t < 1 s Current leakage when the relay is open ILEAK - - 1 nA VOFF = 20 V Capacity between terminals COFF - 40 - pF V = 0, f = 100 MHz, t < 1 s IF Capacity between I/O terminals CI-O - 0.3 - pF f = 1 MHz, VS = 0 V 8 Insulation resistance between I/O terminals RI-O 1000 10 -M VI-O = 500 VDC, ROH 60 % 90% VOUT 10% Turn-ON time tON - 0.3 2 ms IF = 5 mA, RL = 200 , t ON t OFF Turn-OFF time tOFF - 0.2 1 ms VDD = 10 V (See note 2.) 1 Output Input Output InputG3VM-21LR11 MOS FET Relays Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) VDD -- 20 V Operating LED forward current IF -- 20 mA Continuous load current (AC peak/DC) IO - - 900 mA Ambient operating temperature Ta 20 - 65 C Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature LED forward current vs. LED forward voltage IF - Ta IO - Ta IF - VF 70 1200 100 Ta = 25 C 50 60 1000 30 50 800 10 40 5 600 3 30 400 1 20 0.5 200 0.3 10 0.1 0 0 -20 0 20 40 60 80 100 120 -20 0 20 40 60 80 100 120 0.6 0.8 1 1.2 1.4 1.6 1.8 Ambient temperature Ta (C) Ambient temperature Ta (C) LED forward voltage VF (V) Continuous load current vs. On-state voltage On-state resistance vs. Ambient temperature Trigger LED forward current vs. Ambient temperature IO - VON RON - Ta IFT - Ta 1200 0.40 8 Ta = 25 C IO = 900 mA IO = 100 mA IF = 5 mA 0.35 7 IF = 5 mA t < 1 s 800 t < 1 s 0.30 6 400 0.25 5 0 0.20 4 0.15 3 -400 0.10 2 -800 0.05 1 0 -1200 0 -0.2 -0.1 0 0.1 0.2 -40 -20 0 20 40 60 80 100 -40 -20 0 20 40 60 80 100 Ambient temperature Ta (C) On-state voltage VON (V) Ambient temperature Ta (C) Turn ON, Turn OFF time vs. LED forward current Turn ON, Turn OFF time vs. Ambient temperature Current leakage vs. Load voltage tON, tOFF - IF tON, tOFF - Ta ILEAK - VOFF 10 0.5 200 VDD = 10 V VDD = 10 V Ta = 25 C 180 RL = 200 RL = 200 160 Ta = 25 C IF = 5 mA 0.4 140 1 tON 120 tOFF 0.3 100 80 0.1 tOFF 60 0.2 tON 40 20 0.1 0.01 0 110 100 -40 -20 0 20 40 60 80 100 510 15 20 25 LED forward current IF (mA) Ambient temperature Ta (C) Load voltage (V) Output terminal capacitance vs. Load voltage COFF - VOFF 1.0 Ta = 25 C 0.8 0.6 0.4 0.2 0 510 15 20 25 Load voltage (V) Safety Precautions Refer toCommon Precaution for all G3VM models. 2 Output terminal capacitance COFF/COFF (0 V) Continuous load current IO (mA) Turn ON, Turn OFF time tON, tOFF (ms) LED forward current IF (mA) Turn ON, Turn OFF time tON, tOFF (ms) Continuous load current IO (mA) On-state resistance RON () LED forward current IF (mA) Current leakage ILEAK (pA) Trigger LED forward current IFT (mA)