Power PCB Relay G6D-ASI Reduced board space ideal for high-density mounting (45% smaller than the surface area of G6B). Slim package: measures 6.5 W x 17.5 L x 12.5 H mm Switches loads up to 5 A, 250 VAC/30 VDC. Sealed construction allows automatic soldering and cleaning. Long service life: up to 300,000 operations with a 2 A, 250 VAC/30 VDC load. Rated for D150 pilot duty by UL, CSA. Optional mounting socket simplifies relay installation and servicing of finished equipment. RCE RoHS Compliant. Ordering Information To Order: Select the part number and add the desired coil voltage rating, (e.g., G6D-1A-ASI-DC12). Type Contact form Terminal Construction Model Standard SPST-NO PCB Fully sealed G6D-1A-ASI Accessories Connecting Socket Description Model PCB mount socket for G6D relay P6D-04P Specifications Contact Data Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC Contact material Ag alloy Carry current 5 A Max. operating voltage 250 VAC, 30 VDC Max. operating current 5 A Max. switching capacity 1,250 VA, 150 W 500 VA, 60 W Min. permissible load 10 mA at 5 VDC -6 Note: P level: = 0.1 x 10 /operation 60 Power PCB Relay G6D-ASI 127 Coil Data Rated Rated Coil Pick-up Dropout Maximum Power voltage current resistance voltage voltage voltage consumption (VDC) (mA) () (mW) % of rated voltage 5 40 125 70% max. 10% min. 160% at 23 C Approx. 200 12 16.7 720 24 8.3 2,880 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23 C (73F) with a tolerance of 10%. 2. Operating characteristics are measured at a coil temperature of 23 C (73 F). 3. The pick-up voltage is 75% or less of rated voltage if the relay is mounted upside down. Characteristics Contact resistance 100 m max. Operate time 10 ms max. Release time 5 ms max. Operating Mechanical 18,000 operations/hour frequency Electrical 1,800 operations/hour (under rated load) Insulation resistance 1,000 M min. (at 500 VDC) Dielectric strength 3,000 VAC, 50/60 Hz for 1 minute between coil and contacts 750 VAC, 50/60 Hz for 1 minute between contacts of the same polarity Surge withstand voltage 6,000 V, 1.20 x 50 s between coil and contacts Vibration Mechanical durability 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude Malfunction durability 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude 2 Shock Mechanical durability 1,000 m/s (approx. 100 G) 2 Malfunction durability 100 m/s (approx. 10 G) Ambient temperature Operating -25 to 70 C (-13 to 158F) Humidity 5% to 85% RH Life expectancy Mechanical 20 million operations min. (at operating frequency of 18,000 operations/hour) Electrical 70,000 operations min. at rated loads (300,000 operations min for 2A at 250 VAC, 30 VDC, resistive load) Weight Approx. 3 g (0.10 oz) Note: Data shown are of initial value. Characteristic Data Maximum Switching Capacity Life Expectancy Ambient Temperature vs. Maximum Coil Voltage 50 500 200 30 300 180 100 10 160 AC resistive load 250-VAC/30-VDC resistive load 5 50 140 3 30 DC resistive load 120 AC inductive 10 1 load DC inductive cos=0.4 load 100 250-VAC/30 VDC inductive load 5 0.5 (cos=0.4/ L/R=7 ms) 0.3 3 80 0.1 60 0 1 2 3 4 5 6 7 8 9 10 0 3 5 10 30 100 250 500 1,000 02330 40 50 60 70 8090 Switching current (A) Switching voltage (V) Ambient temperature (C) Note: The maximum coil voltage is the maximum voltage that can be applied to the relay coil. 128 Power PCB Relay G6D-ASI Switching current (A) 4 Life Expectancy (x10 operations) Maximum coil voltage (%)