Please contact us about TV certified products. Certified Certified Certified Certified AQ10A2-ZT4/32VDC, Certified AQ3A2-ZT4/32VDC, AQ1AD2-3/28VDC AQ1AD2-3/28VDC AQ3A2-ZT4/32VDC, AQ1AD2-3/28VDC and AQ3A2-J-ZT4/32VDC and VDE and AQ2AD1-3/28VDC and AQ2AD1-3/28VDC and AQ3A2-J-ZT4/32VDC AQ2AD1-3/28VDC AQ10A2-ZT4/32VDC High capacity up to 10A AQ1 RELAYS PCB terminal type SSR FEATURES 1. 10A high-capacity realized for PC 5. Reduced noise generation board terminal (when using heat sink) The load will operate at close to zero SSR for compact PC boards with 10 A voltage even when the input signal is capacity that is two times greater than applied during a cycle. Also, even if an our previous model. It is suitable for long- input signal is cancelled during a cycle, life, highly frequent control. the load is cut off at close to zero current. 2. VDE (EN60950-1) reinforced For this reason, hardly any noise is insulation compliant produced and radio frequency Fully satises demand for safety by interference (RFI) and electromagnetic guaranteeing compliance with interference (EMI) are kept to a minimum. EN60950-1 safety standard and featuring 6. Built-in snubber circuit prevents 3,000 V reinforced insulation (AQ3A2- malfunction. ZT4/32VDC, AQ3A2-J-ZT4/32VDC and AQ10A2-ZT4/32VDC). TYPICAL APPLICATIONS 3. Superior anti-vibration and anti- shock characteristics Printing machines The body is molded as a single unit with Packing machines ame resistant resin which makes it Trafc signal control highly resistant against vibration and Automatic ticket punchers shock, and gives it superior protection Terminal equipment of data processing from environment. The body can also be Computer peripherals washed. NC machines 4. Vertical types with SIL terminal arrangement and at types are available. 1) The vertical type is available in thicknesses of 10 mm (2 A and 3 A types) and 12 mm (10 A type). Terminal arrangement is SIL in integral multiples of 2.54 mm (0.1 inch). 2) The height of the at type is 12 mm. The terminal arrangement is DIL in RoHS compliant integral multiples of 2.54 mm. ORDERING INFORMATION AQ Load current 1 A, 2 A, 3 A, 10 A Load voltage 2: 75 to 250 V AC D1: 3 to 60 V DC D2: 10 to 200 V DC Shape Nil: Vertical type J: Flat type Nil: DC output ZT: Zero-cross AC output (Phototriac coupler) Input voltage 3/28 V DC: 3 to 28 V DC 4/32 V DC: 4 to 32 V DC * Random types are available by custom order. ASCTB24E 201509-T 1AQ1 TYPES 1. AQ1 Solid State Relays Load Isolation Zero-cross function Type Load current Load voltage Input voltage Part No. Vertical 3 A 75 to 250 V AC 4 to 32 V DC AQ3A2-ZT4/32VDC 1 AC Phototriac coupler Zero-cross* Flat 3 A 75 to 250 V AC 4 to 32 V DC AQ3A2-J-ZT4/32VDC 2 Vertical 10 A* 75 to 250 V AC 4 to 32 V DC AQ10A2-ZT4/32VDC Vertical 1 A 10 to 200 V DC 3 to 28 V DC AQ1AD2-3/28VDC DC Phototransistor Vertical 2 A 3 to 60 V DC 3 to 28 V DC AQ2AD1-3/28VDC Standard packing: Carton 20 pcs., Case 200 pcs. Notes: *1. Random type also available. Please inquire. *2. 5 A without heat sink 2. Heat sink for AQ1 solid state relay Product name Part No. Heat sink for AQ10A2-ZT4/32VDC AQ-HS-5A Standard packing: Carton 20 pcs., Case 200 pcs. SPECIFICATIONS 1. Rating (Ambient temperature: 20C 68F, Ripple factor: less than 1%) AC output type Type DC output type Zero-cross Remarks Item 3 A type 10 A type 1 A type 2 A type Input voltage 4 to 32 V DC 3 to 28 V DC Input impedance Approx. 1.6 k Input 1 * side Input current, max. 20 mA Drop-out voltage, min. 1.0 V 0.8 V 2 5 Max. load current* 3 A 10 A* 1 A 2 A Refer to REFERENCE DATA 1. Load current vs. ambient Load voltage 75 to 250 V AC 10 to 200 V DC 3 to 60 V DC temperature characteristics. Non-repetitive surge AC: In one cycle at 60 Hz, 100 A 5 A 3 current* DC: 1s Load AC: at 200 V, 60Hz side Max. OFF-state leakage 5 mA 1 mA DC: When maximum load current voltage is applied. Max. ON-state voltage 1.6 V 1.6 V 2.3 V At Max. carrying current drop 4 Min. load current* 50 mA 5 mA Notes: *1. Refer to REFERENCE DATA 3. Input current vs. input voltage characteristics. *2. Refer to REFERENCE DATA 1. Load current vs. ambient temperature. *3. Refer to REFERENCE DATA 2. Non-repetitive surge current vs. carrying time. *4. When load current is below the rating, refer to Cautions for Use. *5. When heat sink (AQ-HS-5A) is installed. The max. load current is 5 A when heat sink is not installed. 2. Characteristics (Ambient temperature: 20C 68F, Ripple factor: less than 1%) AC output Type Zero-cross DC output Remarks Item 3 A type 10 A type Operate time, Max. 1/2 cycle of voltage sine wave + 1 ms 0.5 ms Release time, Max. 1/2 cycle of voltage sine wave + 1 ms 2 ms Insulation resistance, Min. 100 M for input, output and case 100 M for input, output at 500 V DC 4,000 Vrms between input and output 3,000 Vrms Breakdown voltage For 1 minute 2,500 Vrms between input, output and case between input-output 10 to 55 Hz 1 hour for Destructive 10 to 55 Hz at double amplitude of 2 mm at double amplitude of 2 mm X, Y, Z axis Vibration resistance 10 to 55 Hz 10 minutes for Functional 10 to 55 Hz at double amplitude of 2 mm at double amplitude of 2 mm X, Y, Z axis 5 times each for 2 2 Destructive Min. 980 m/s 100 G Min. 980 m/s 100 G X, Y, Z axis Shock resistance 4 times each for 2 2 Functional Min. 980 m/s 100 G Min. 980 m/s 100 G X, Y, Z axis Ambient temperature 30C to +80C 22F to +176F Storage temperature 30C to +100C 22F to +212F Operational method Zero-cross (Turn-ON and Turn-OFF) ASCTB24E 201509-T 2