AQ-F
SSR for high-frequency
switching of industrial
AQ-F RELAYS
equipment
FEATURES TYPICAL APPLICATIONS
1. Suitable for high-capacity and high- 1. Drive for small-sized motor, heater,
frequency switching solenoid and electromagnetic
2. Same size, same terminal valves.
arrangement as HC relay 2. NC machine
Sockets for HC relays are applicable 3. Printing machine
3. Two load types available: 4. Machine tool
DC output type (2 A, 3 A) 5. Robot for industrial use
AC output type (2 A, 3 A) 6. Wrapping and packing machine
4. Wide range of input voltage:
3 V to 28 V
RoHS compliant
TYPES
Types Load current Load voltage Input voltage Part No.
2A AQF2A2-ZT3/28V DC
AC output 75 to 250V AC 3 to 28V DC
3A AQF3A2-ZT3/28V DC
2A AQF2AD1-3/28V DC
DC output 3 to 60V DC 3 to 28V DC
3A AQF3AD1-3/28V DC
Standard packing; Carton: 20 pcs., Case: 200 pcs.
RATING
1. Ratings (Ambient temperature: 20C 68F, Input voltage ripple: 1% or less)
AC output DC output
Type
Remarks
Item
2A 3A 2A 3A
Input voltage 3 to 28 V DC
Input Input impedance Approx. 1.6 k
1
*
side
Drop-out voltage,
0.8 V DC
min.
2 2 2 2
Max. load current 2 A* 3 A* 2 A* 3 A* Ta = Max. 40C 104F
Load voltage 75 to 250 V AC 3 to 60 V DC
Non-repetitive surge AC: In one cycle at 60 Hz
3 3 3
80 A* 5 A* 6 A*
current DC: 1 s
Load
Max. OFF-state AC: at 60 Hz 200 V
side
5 mA 1 mA
leakage current DC: at 60 V
Max. ON-state
1.6 V at max. carrying current
voltage drop
4 4
Min. load current 50 mA* 5 mA*
Notes: *1. Refer to REFERENCE DATA 3. Input current vs. input voltage.
*2. Refer to REFERENCE DATA 1. Load current vs. ambient temperature.
*3. Refer to REFERENCE DATA 2. Non-repetitive surge current vs. carrying time.
*4. When the load current is less than the rated minimum load current, please refer to Cautions for Use of SSR.
2. Characteristics (Ambient temperature: 20C 68F, Input voltage ripple: 1% or less)
AC output DC output
Type
Remarks
Item
2A 3A 2A 3A
Operate time max. 1/2 cycle of voltage sine wave + 1 ms 0.5 ms
Release time, max. 1/2 cycle of voltage sine wave + 1 ms 2 ms
Insulation resistance, min. 100 M between input and output at 500 V DC
Breakdown voltage 2,000 Vrms between input and output for 1 min.
Destructive 10 to 55 Hz double amplitude of 3 mm 1 hour for X, Y, Z axes
Vibration
resistance
Functional 10 to 55 Hz double amplitude of 3 mm 10 min. for X, Y, Z axes
2
Destructive Min. 980 m/s {100 G} 5 times each for X, Y, Z axes
Shock
2
resistance
Functional Min. 980 m/s {100 G} 4 times each for X, Y, Z axes
Ambient temperature 30C to +80C 22F to +176F
Storage temperature 30C to +100C 22F to +212F
Operational method Zero-cross (Turn-ON and Turn-OFF)
ASCTB215E 201209-T1
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/AQ-F
REFERENCE DATA
1. Load current vs. ambient temperature 2-(1). Non-repetitive surge current vs. carrying 2-(2). Non-repetitive surge current vs. carrying
characteristics time characteristics time characteristics
Use load current within range specied in the gure (AC output type) (DC output type)
below
110 22
3.0
100
20
3 A type
90
18
2.5
80
2 A type 16
70
2.0 14
60 12
3 A type
1.5
50
10
40 8
1.0 2 A type
30
6
20 4
0.5
10
2
0
0
0
30 0 20 40 60 80
12345710 20 304050 70100 10 20 30 4050 70100 200 300 500 1,000
400 700
Ambient temperature, C
No. of cycles at 60 Hz
Time,ms
3. Input current vs. input voltage characteristics
50
45
40
35
30
25
20
15
10
5
0
3 10 15 20 25 30
Input voltage, V
The CAD data of the products with a CAD Data mark can be downloaded from: