TGL2210-SM 0.056 GHz 100 Watt VPIN Limiter Product Overview The Qorvo TGL2210-SM is a high-power receive protection circuit (limiter) operating from 0.05- 6GHz. Capable of withstanding up to 100 W incident power levels, the TGL2210-SM allows < 17 dBm flat leakage to pass through and contributes < 0.7 dB in insertion loss. Using Qorvos passive GaAs VPIN technology, the TGL2210-SM does not require bias and is offered in a QFN 4x4 mm 20L small 4 x 4 (mm) plastic overmold package. This simplifies system integration while maximizing performance and protection. Key Features The TGL2210-SM is ideal for commercial and military Frequency Range: 0.05 to 6.0 GHz radar applications, communications systems and Insertion Loss: < 0.7 dB electronic warfare where protecting sensitive receive Peak Power Handling: 100 W (pulsed) components from damage is critical. Flat Leakage: < 17 dBm Lead-free and RoHS compliant. Passive (no DC bias required) Recovery time < 40 ns QFN Package Dimensions: 4.0 x 4.0 x 0.85 mm Functional Block Diagram Applications Receive Chain Protection Commercial and Military Radar Communications Electronic Warfare Ordering Information Part Description Top View TGL2210-SM 0.056.0 GHz 100W VPIN Limiter TGL2210-SMEVB-01 Evaluation Board Data Sheet Rev. B, October 2, 2018 Subject to change without notice 1 of 10 www.qorvo.com TGL2210-SM 0.056.0 GHz 100 Watt VPIN Limiter Absolute Maximum Ratings Recommended Operating Conditions Parameter Min Typ Max Units Parameter Rating Incident Power, Pulsed (PW = 10s, DC Operating Temperature Range -40 +25 +85 C 110 W = 10%), 50 , 85 C Passive No Bias Incident Power, CW, 50 , 25 C 85 W Electrical specifications are measured at specified test conditions. Specifications are not guaranteed over all recommended operating Incident Power, CW, 50 , 85 C 70 W conditions. Mounting Temperature 260 C (30 s max) Storage Temperature -55 to 150 C Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Electrical Specifications Parameter Conditions Min Typical Max Units Operational Frequency Range 0.05 6.0 GHz Insertion Loss, Un-Tuned Freq = 3.5 GHz 0.6 0.85 dB (1) Insertion Loss, Tuned Freq = 3.5 GHz 0.4 dB Input Return Loss, Un-Tuned 10 11 dB Output Return Loss, Un-Tuned 10 11.5 dB Flat Leakage Power P > 30 dBm < 17 dBm IN Pulse Recovery Time < 40 ns Spike Leakage < 0.5 dB Insertion Loss Temperature Coefficient 0.001 dB/ C Notes: Test conditions unless otherwise noted: Temp=+25C, 50 system. 1. Tuned EVB to improve 2-5 GHz Thermal and Reliability Information Parameter Test Conditions Value Units 4.5 GHz, CW, 50 , 25 C 31 W Incident Power (1) (168 hours RF Operational Life Test ) 100 W 4.5 GHz, Pulsed, PW=10 s, DC=10%, 50 , 25 C Notes: 1. Test was terminated at 168 hours. Insertion Loss remained 1 dB for device under test. Data Sheet Rev. B, October 2, 2018 Subject to change without notice 2 of 10 www.qorvo.com