Bulletin No. PAXLA-D Drawing No. LP0722 Released 04/14 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL PAXLA - PAX LITE DC VOLT/CURRENT/PROCESS METER 5 DIGIT, 0.56 HIGH RED LED DISPLAY PROGRAMMABLE SCALING AND DECIMAL POINTS PROGRAMMABLE USER INPUT DUAL 5 AMP FORM C RELAY UNIVERSALLY POWERED NEMA 4X/IP65 SEALED FRONT BEZEL OPTIONAL CUSTOM UNIT OVERLAY W/ BACKLIGHT U C R L US LISTED MINIMUM AND MAXIMUM DISPLAY CAPTURE IND. CONT. EQ. 51EB For Model No. PAXLA0U0 Only GENERAL DESCRIPTION SPECIFICATIONS The PAXLA is a versatile meter available as a DC volt, current, or process 1. DISPLAY: 5 digit, 0.56 (14.2 mm) intensity adjustable Red LED (-19999 to meter with scaling and dual Form C relay outputs. The meter is programmed 99999) through the front panel buttons and the use of jumpers. The RST Key will also 2. POWER REQUIREMENTS: function as a front panel display reset. AC POWER: 50 to 250 VAC 50/60 Hz, 12 VA Once the front panel programming is complete, the buttons can be disabled Isolation: 2300 Vrms for 1 min. to all inputs and outputs by a user input setting. The meter has been specifically designed for harsh DC POWER: 21.6 to 250 VDC, 6 W industrial environments. With a NEMA 4X/IP65 sealed bezel and extensive DC Out: +24 VDC 100 mA if input voltage is greater than 50 VAC/VDC +24 VDC 50 mA if input voltage is less than 50 VDC testing to meet CE requirements, the meter provides a tough yet reliable application solution. 3. INPUT RANGES: Jumper Selectable D.C. Voltages: 200 mV, 2 V, 20 V, 200 V, 10 V ACCURACY MAX SAFETY SUMMARY INPUT INPUT TEMP. 23 C LESS INPUT RESOLUTION RANGE IMPEDANCE COEFFICIENT All safety regulations, local codes and instructions that appear in this and THAN 85% RH SIGNAL corresponding literature, or on equipment, must be observed to ensure personal 200 mV 0.1% of span 1.033 M 75 VDC 10 V 70 ppm /C safety and to prevent damage to either the instrument or equipment connected to 2 V 0.1% of span 1.033 M 75 VDC 0.1 mV 70 ppm /C it. If equipment is used in a manner not specified by the manufacturer, the 10 V 0.1% of span 250 VDC 1 mV 70 ppm /C 1.033 M protection provided by the equipment may be impaired. 20 V 0.1% of span 1.033 M 250 VDC 1 mV 70 ppm /C 200 V 0.1% of span 1.033 M 250 VDC 10 mV 70 ppm /C D.C. Currents: 200 A, 2 mA, 20 mA, 200 mA ACCURACY MAX INPUT INPUT TEMP. CAUTION: Risk of Danger. 23 C LESS INPUT RESOLUTION CAUTION: Risk of electric shock. RANGE IMPEDANCE COEFFICIENT Read complete instructions prior to THAN 85% RH SIGNAL installation and operation of the unit. 200 0.1% of span 1.111 K 15 mA 10 nA 70 ppm /C 2 mA 0.1% of span 111 50 mA 0.1 A 70 ppm /C 20 mA 0.1% of span 150 mA 1 A 70 ppm /C ORDERING INFORMATION 11 200 mA 0.1% of span 1 500 mA 10 A 70 ppm /C MODEL NO. DESCRIPTION PART NUMBER Volt/Current/Process Meter with Dual Relay Output PAXLA000 D.C. Process: 4 to 20 mA, 1 to 5 VDC, 0/1 to 10 VDC INPUT RANGE SELECT RANGE PAXLA UL Listed Volt/Current/Process Meter with Dual PAXLA0U0 Relay Output 4 - 20 mA Use the 20 mA range 1 - 5 VDC Use the 10V range PAXLBK Unit Label Kit Accessory PAXLBK10 1 - 10 VDC Use the 10V range DIMENSIONS In inches (mm) MAX MNI V 8.8.8.8.8 1.95 1.75 SP1PS 2 (49.5) (44.5) 1 2 5 6 3 4 7 8 9 10 11 12 13 14 15 PAR SEL RST .10 4.10 3.80 3.60 (91.4) (2.5) (104.1) (96.5) 14. OVERRANGE/UNDERRANGE INDICATION: 11. CONNECTIONS: High compression cage-clamp terminal block Input Overrange Indication: OLOL. Wire Strip Length: 0.3 (7.5 mm) Input Underrange Indication: ULUL. Wire Gage: 30-14 AWG copper wire Display Overrange/Underrange Indication: ...../-..... Torque: 4.5 inch-lbs (0.51 N-m) max. 5. A/D CONVERTER: 16 bit resolution 12. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 outdoor use. IP20 6. UPDATE RATES: Touch safe. Installation Category II, Pollution Degree 2. One piece bezel/ A/D conversion rate: 20 readings/sec. case. Flame resistant. Synthetic rubber keypad. Panel gasket and mounting Display update: 500 msec min. clip included. 7. USER INPUT: 13. CERTIFICATIONS AND COMPLIANCES: User Input: Software selectable pull-up (24.7 K) or pull-down resistor CE Approved (20 K ) that determines active high or active low input logic. EN 61326-1 Immunity to Industrial Locations Trigger levels: V = 1.0 V max V = 2.4 V min V = 28 VDC IL IH MAX Emission CISPR 11 Class A Response Time: 5 msec typ. 100 msec debounce (activation and release) Safety requirements for electrical equipment for measurement, control, and 2 8. MEMORY: Nonvolatile E PROM retains all programming parameters when laboratory use: power is removed. EN 61010-1: General Requirements 9. OUTPUT: RoHS Compliant Type: Dual FORM-C relay UL Listed: File E137808 For Model No. PAXLA0U0 Only Isolation To Sensor & User Input Commons: 1400 Vrms for 1 min. Type 4X Enclosure rating (Face only) Working Voltage: 150 Vrms IP65 Enclosure rating (Face only) Contact Rating: 5 amps 120/240 VAC or 28 VDC (resistive load), 1/8 IP20 Enclosure rating (Rear of unit) H.P. 120 VAC (inductive load) 14. WEIGHT: 10.4 oz. (295 g) Life Expectancy: 100,000 minimum operations Response Time: Turn On Time: 4 msec max. Turn Off Time: 4 msec max. 10. ENVIRONMENTAL CONDITIONS: Operating temperature: 0 to 50 C Storage temperature: -40 to 70 C Operating and storage humidity: 0 to 85% max. RH (non-condensing) Vibration to IEC 68-2-6: Operational 5 to 150 Hz, 2g. Shock to IEC 68-2-27: Operational 30 g (10g relay). Altitude: Up to 2,000 meters 1.0 IstallIn gn the Meter While holding the unit in place, push the panel latch over the rear of the unit Installation so that the tabs of the panel latch engage in the slots on the case. The panel latch The PAX meets NEMA 4X/IP65 requirements when properly installed. The should be engaged in the farthest forward slot possible. To achieve a proper seal, unit is intended to be mounted into an enclosed panel. Prepare the panel cutout tighten the latch screws evenly until the unit is snug in the panel (Torque to to the dimensions shown. Remove the panel latch from the unit. Slide the panel approximately 7 in-lbs 79N-cm ). Do not over-tighten the screws. gasket over the rear of the unit to the back of the bezel. The unit should be installed fully assembled. Insert the unit into the panel cutout. Installation Environment The unit should be installed in a location that does not exceed the maximum operating temperature and provides good air circulation. Placing the unit near PANEL devices that generate excessive heat should be avoided. The bezel should be cleaned only with a soft cloth and neutral soap product. Do NOT use solvents. Continuous exposure to direct sunlight may accelerate the BEZEL aging process of the bezel. Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to operate the keypad of the unit. LATCHING PANEL SLOTS LATCH PANEL CUT-OUT LATCHING TABS +.03 3.62 -.00 +.8 (92 ) -.0 +.02 1.77 -.00 PANEL +.5 GASKET (45 ) -.0 PANEL MOUNTING SCREWS 2