Datasheet EARTH LEAKAGE CURRENT DETECTOR IC SERIES EARTH LEAKAGE CURRENT DETECTOR IC BD95850F-LB Description Key Specifications This is the product guarantees long time support in Operating Supply Voltage Range: 7V to 13V Industrial market. Operating Temperature Range: -30C to +95C The BD95850F-LB is the monolithic IC integrates earth Supply Current: 830A(Typ) leakage detection, signal amplification, and overvoltage Trip Voltage(Leakage Detection DC Voltage): 7.5mV detection . Output Current Ability : -100 A(Min) Especially, its suitable for high-sensitivity and high -speed operation use, and, since the operating temperature range is wide, it can be used for various applications. Features Long Time Support Product for Industrial Applications Package W(Typ) x D(Typ) x H(Max) Small Temperature Fluctuation SOP14 8.70mm x 6.20mm x 1.71mm and High Input Sensitivity Wide Operating Temperature Range Detection Mode Selectable (1 count method /1.5 count method) Applications Earth leakage circuit breaker Earth leakage circuit relay Industrial equipment Typical Application Circuit Example SCR VCC VCC C C TTDC OFFC C OS R VS V 14 13 12 11 10 9 8 Z C VS VS VCC PSAV IBLI TTDC OFFC SCRT Overvoltage Power Reset Detection Supply SCR Driver Leakage Detection IREF VREF ILKI TRC1 TRC2 PSEL 1 234 567 Trip Coil C C RC1 RC2 VCC ZCT:Zero-phase Current Transformer Product structureSilicon monolithic integrated circuit This product has no designed protection against radioactive rays www.rohm.com TSZ02201- 0RCR1GZ00130-1-2 2014 ROHM Co., Ltd. All rights reserved. 1/19 TSZ22111 .14.001 13.Jun.2014 Rev.001DatasheetDatasheet BD95850F-LB Pin Configurations Block Diagrams SOP14 (TOP VIEW) 14 13 12 11 10 9 8 14 13 12 11 10 9 8 VS VCC PSAV IBLI TTDC OFFC SCRT Overvoltage Reset Detection Power Supply SCR Drive Leakage Detection IREF VREF ILKI TRC1 TRC2 PSEL 12345 6 7 1 2 3 4 5 6 7 Pin Descriptions Pin No. Symbol Function Pin No. Symbol Function 1 GND Ground 8 SCRT Output for driving thyristor Connect a resistor to set constant 2 IREF 9 OFFC Connect a capacitor to set reset time current of the internal circuits Connect a capacitor to set over-voltage 3 VREF Reference voltage output 10 TTDC detection time 4 ILKI Input of leakage detection signal 11 IBLI Input of over-voltage detection signal Connect a capacitor for charge Enable pin for overvoltage detection 5 TRC1 12 PSAV current of negative detection function Connect a capacitor for charge 6 TRC2 13 VCC Internal power supply current of positive detection Logic function switching pin for 7 PSEL 14 VS Power supply leakage detection Absolute Maximum Ratings (T =25C) A Parameter SymbolRating Unit Condition Supply Current I 4 mA S (Note 1) Supply Voltage V 18 V S Input Voltage V -1.5 to +1.5 V across ILKI and VREF IN Input Current I -5 to +5 mA across ILKI and VREF IN Input Current of VREF I 10 mA across VREF and GND VREF IREF/REF/IN/TRC1/TRC2/ Input Voltage V 8 V PSEL/SCRT/OFFC/PSAV/ XXXX TTDC/VCC/IBLI Input Voltage of Overvoltage Detection V -0.3 to +5.0 V across IBLI and GND IBLI Input Current of Overvoltage Detection I 4 mA across IBLI and GND IBLI (Note 2) Power Dissipation P 0.56 W D Operating Temperature T -30 to +95 C opr Storage Temperature T -55 to +150 C stg (Note 1) Supply voltage is limited by internal clamping circuit . Please refer to maximum current voltage of the electrical characteristic item. (Note 2) Mounted on 70mm x 70mm x 1.6mm glass epoxy board. Reduce 4.5mW per 1C above 25C. Caution: Operating the IC over the absolute maximum ratings may damage the IC. The damage can either be a short circuit between pins or an open circuit between pins and the internal circuitry. Therefore, it is important to consider circuit protection measures, such as adding a fuse, in case the IC is operated over the absolute maximum ratings. Recommended Operating Conditions Parameter SymbolRating Unit Supply Voltage V 7 to 13 V Sopr www.rohm.com TSZ02201- 0RCR1GZ00130-1-2 2014 ROHM Co., Ltd. All rights reserved. 2/19 TSZ22111 .15.001 13.Jun.2014 Rev.001