DIN Rail Mount DataSheet AC DC SeriesOne DR Series Ratings of 6 & 12 Amps Load voltage ratings of 1-60 VDC, 1-100 VDC, 24-280 VAC and 48-600 VAC Fits standard 35mm DIN Rail LED input status indicator AC or DC control Zero Voltage (resistive loads) or Instantaneous (inductive loads) turn-on output UL and cUL Listed, HP Rated CE & RoHS Compliant UL 508 Endurance Rating for Enhanced Reliability UL Class I and II, Division 2, for Hazardous Locations PRODUCT SELECTION Control Voltage 280, 6 A 280V, 12 A 600V, 6 A 600V, 12 A 60V, 6 A 60V, 12 A 100V, 6 A 100V, 12 A 4-32 VDC DR24D06 DR24D12 DR48D06 DR48D12 DR06D06 DR06D12 DR10D06 DR10D12 90-140 VAC DR24B06 DR24B12 DR48B12 200-280 VAC DR24A06 DR24A12 DR48A12 18-36 VAC DR24E06 DR24E12 DR48E12 AVAILABLE OPTIONS Operating Voltage Switching Type Blank: Zero Voltage Turn-On 06: 1-60 VDC Rated Load Current (AC Output Only) 10: 1-100 VDC 06: 6 Amps 24: 24-280 VAC R: Instantaneous Turn-On 12: 12 Amps (AC Output, D suffix Only) Series 48: 48-600 VAC DR 06 D 12 X R Control Voltage Agency Approvals X: ATEX II 3G Ex nA IIC T4 Gc D: 4-32 VDC A: 200-265 VAC AC approved B: 90-140 VAC Output Only E: 18-36 VAC (1) Required for valid part number For options only and not required for valid part number (2) OUTPUT SPECIFICATIONS AC Output Description DR24x06 DR24x12 DR48x06 DR48X12 Operating Voltage Range (47-63Hz) Vrms 24-280 24-280 48-600 48-600 Transient Overvoltage Vpk 600 600 1200 1200 Maximum Load Current, resistive Arms (3) 6 12 6 12 Minimum Load Current mArms 150 150 150 150 Maximum Off-State Leakage Current Rated Voltage mArms 0.1 0.1 0.1 0.1 Minimum Off-State dv/dt Maximum Rated Voltage V/sec (4) 500 500 500 500 Maximum On-State Voltage Drop Rated Current Vrms 1.3 1.3 1.3 1.3 Maximum Surge Current (50/60Hz, 1 cycle) Apk 285/300 715/750 285/300 715/750 Maximum It for Fusing (50/60 Hz, 1/2 cycle) A sec 400/375 2560/2330 410/375 2560/2330 HP Rating UL 508/IEC60947 HP (KW) 240V 1/2 (.37) 1 (.75) 1/2 (.37) 1 (.75) HP Rating UL 508/IEC60947 HP (KW) 380V 1 (.75) 2 (1.5) 1 (1.5) 2 (1.5) HP Rating UL 508/IEC60947 HP (KW) 480V N/A 3 (2.2) 2 (1.5) 3 (2.2) Minimum Power Factor (at Maximum Load) 0.5 0.5 0.5 0.5 Min/Max stranded wire 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG Min/Max solid wire 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG Weight (Typical) 1.76 oz. (50g) 3.17 oz. (90g) 1.76 oz. (50g) 3.17 oz. (90g) Do not forget to visit us at: www.crydom.com Copyright 2017 Crydom Inc. Specifications subject to change without notice.DIN Rail Mount DataSheet (2) OUTPUT SPECIFICATIONS DC Output Description DR06D06 DR10D06 DR06D12 DR10D12 Operating Voltage VDC 1-60 1-100 1-60 1-100 Maximum Load Current Adc (3) 6 6 12 12 Minimum Load Current mAdc 2.5 2.5 2.5 2.5 Maximum Off-State Leakage Current Rated Voltage mA 0.1 0.1 0.1 0.1 Maximum On-State Voltage Drop Rated Current Vpk 0.6 0.6 0.6 0.6 Maximum Surge Current (10ms) Apk 60 60 100 100 0.1 0.1 0.45 0.45 On-State resistance at rated current Ohms 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG Min/Max stranded wire 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG Min/Max solid wire 1.94 oz. (55g) 1.76 oz. (50g) 3.17 oz (90g) 3.17 oz.(90g) Weight (typical) (2) INPUT SPECIFICATIONS Description DRxxDxx DRxxBxx DRxxAxx DRxxExx Control Voltage Range (5) 4-32 VDC 90-140 Vrms 200-265 Vrms 18-36 Vrms (1) Minimum Turn-On Voltage 4.0 VDC 90 Vrms 200 Vrms 18 Vrms Must Turn-Off Voltage 1.0 VDC 40 Vrms 4 Vrms 10 Vrms Minimum Input Current for mA (6) 9 3 2.5 3.5 Maximum Input Current for mA (6) 11 5 3.3 8 Maximum Turn-on Time msec (7) (8) 1/2 Cycle 20 msec 20 msec 20 msec 1/2 Cycle 30 msec 30 msec Maximum Turn-off Time msec (9) 30 msec Min/Max stranded/solid wire 22/16 AWG 22/16 AWG 22/16 AWG 22/16 AWG (2) GENERAL SPECIFICATIONS Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms (10) 9 10 Ohm Minimum Insulation Resistance ( 500 VDC) Maximum Capacitance, Input/Output 10 pF Ambient Operating Temperature Range -30 to 80 C Ambient Storage Temperature Range -30 to 100 C Recommended Terminal Screw Torque Range 4.4-7.0 in-lb (0.5-0.8Nm) GENERAL NOTES (1) E option is UL certied for AC control voltage, but it works also with 18-36 VDC input range. (2) All parameters at 25C unless otherwise specied. (3) See Derating curves (4) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (5) DC control includes reverse polarity protection. (6) Input circuitry incorporates active current limiter. (7) Turn-on time for DC control random turn-on versions is 0.1 msec. (8) Turn-on time for DC output 600sec. (9) Turn-off time for DC output 300sec. (10) 2500Vrms for DC output. Standards of Compliance IEC 62314 LC A, Resistive or Slightly Inductive Load Ratings: 12 A 40C ambient for DR24x12, 12 A 40C ambient for DR48x12 LC A, Resistive or Slightly Inductive Load Ratings: 6 A 40C ambient for DR24x06, 6 A 40C ambient for DR48x06 LC B, Motor Loads Ratings: 0.75KW 240 VAC for DR24x06 and 2.2KW 480 VAC DR48x12 LC B, Motor Loads Ratings: 0.375KW 240 VAC for DR24x06 and 1.5KW 480 VAC DR48x12 Shock and Vibration (Applies to all part numbers) Vibration Resistence according to IEC 60068-2-6: 0.35mm and 0.75mm Amplitude over 10-55 Hz Shock Resistance according to IEC 60068-2-27: 15g/11ms EMC (Applies to all part numbers) IEC 61000-4-2: Electrostatic Discharge- Level 3 IEC 61000-4-4: Electrically Fast Transients- Level 3 IEC 61000-4-5: Electrical Surges- Level 3 ANSI / ISA 12.12.01-2013 Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2 Hazadous (classied) locations This equipment is open-type device and is meant to be installed in an enclosure suitable for the enviroment such that the equipment is only accesible with the use of a tool suitable for use in Class 1, Division 2, Group A,B,C and Hazardous locations, or Nonhazardous locations only WARNING-Explosion Hazard- Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations WARNING-Explosion Hazard- Substitution of any component may impair suitability for Class I, Division 2 Do not forget to visit us at: www.crydom.com Copyright 2017 Crydom Inc. Specifications subject to change without notice.