GPC200 Commercial/GPM200 Medical
200 Watt Global Performance Switchers
FEATURES:
Wide-range ac input 85-264 Vac
2-year warranty
Conducted EMI exceeds FCC Class B and CISPR 22
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
Commercial Approved to UL1950, IEC950 and
CSA22.2-234 L3
Medical Approved to UL2601-1, IEC601-1 and
CSA22.2 No. 601
Multiple outputs
marked to LVD
Power Fail
SPECIFICATIONS:
TTL- or CMOS-compatible output goes low (< 0.5 V) 5 ms
Ac Input before output voltage drops more than 4% below nominal
voltage upon loss of ac power. The signal is factory set to trip on
85-264 Vac, 47-63 Hz single phase.
84 to 94 Vac brown-out depending upon incoming line impedance
and distortion. Other settings are available to the user through
Input Current
adjustment of built-in potentiometer.
Maximum input current at 120 Vac, 60 Hz with full rated output
load: 5.5 A
Output Noise
Hold-Up Time
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode.
20 ms minimum from loss of ac input at full load, nominal line
Measured with noise probe directly across output terminals of
(115 Vac).
the power supply.
Output Power
Transient Response
150 W convection; 200 with 26 cfm air; 220 W peak. Peak ratings
Main output500 s typical response time for return to within
are for 60 s maximum duration, 10% duty cycle. During peak
0.5% of final value for a 50% load step change. i/ t<0.2 A/s.
load condition, output regulation may exceed total regulation
Maximum voltage deviation is 3.5%. Startup/shutdown overshoot
limits.
less than 3%.
Overload Protection
Remote Sense
Fully protected against short circuit and output overload. Short
Provided as a standard feature on main 5 V output.
circuit protection is cycling type power limit on outputs 1 & 2;
foldback type on outputs 3 & 4. Recovery after fault is automatic.
Voltage Adjustment
See output ratings chart for additional notes or conditions.
Built-in potentiometer adjusts voltage 5% on output 1 & 2.
Overvoltage Protection
EMI/EMC Compliance
Main outputs: 124% 12% typical.
All models include built-in EMI filtering to meet the following
emissions requirements:
Efficiency
EMI SPECIFICATIONS COMPLIANCE LEVEL
Minimum 65% at full rated load, nominal input voltage, depending
Conducted Emissions GPC200 EN55022 Class B; FCC Class B
on model and load distribution.
Conducted Emissions GPM200 EN55011 Class B; FCC Class B
Static Discharge EN61000-4-2, 6 kV contact, 8 kV air
Input Protection
RF Field Susceptibility EN61000-4-3, 3 V/meter
Internal ac fuse provided. Designed to blow only if a catastrophic
Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz
failure occurs in the unit.
Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com.
Inrush Current Commercial Leakage Current
Inrush is limited by internal thermistors. Inrush at 240 Vac under
0.95 mA 254 Vac @ 60 Hz input (with no deviations).
cold start conditions will not exceed 60 A.
Commercial Safety
Temperature Coefficient Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and
EN60950. UL file #E135803 commercial; CSA #LR46516 all
0.03%/C typical on all outputs.
models. The output(s) are intended for safety earthed Signal
Output and Intermediate Circuits only. All dc outputs are SELV
Thermal Shutdown
under normal and single fault conditions.
Provided as a standard feature. Designed to protect unit from
prolonged overtemperature.
Medical Leakage Current
60 A 254 Vac @ 60 Hz input.
Environmental
Designed for 0 to 50C operation at full rated output power;
Medical Safety
derate output current and total output power by 2.5% per C
Approved to UL2601-1, CSA-C22.2 No. 601 Level 3 and IEC601.
above 50C. See Environmental and Packaging Specifications
UL file E116994; CSA #LR46516. The output(s) are intended for
on next page.
safety earthed Signal Output and Intermediate Circuits only. The
output(s) are not acceptable for patient connection without
additional isolation. All dc outputs are SELV under normal and
single fault conditions.
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com
64GPC200 Commercial/GPM200 Medical 200 Watt Multiple Output
Commercial Medical Output Output Output Total
Output No. Output Output Peak Noise P-P
Model Model Minimum Maximum (B) Maximum (C) Regulation (A)
GPC200A GPM200A 1 +5 V 4 A 18 A 26 A 32 A 50 mV 2%
2 +12 V 0 A 5 A 8 A 12 A 120 mV 2%
3 -12 V 0 A 1 A 1.2 A 1.5 A 120 mV 3%
4 12 V (D) 0 A 3 A 4 A 4.5 A 120 mV 3%
GPC200B GPM200B 1 + 5 V 4 A 18 A 26 A 32 A 50 mV 2%
2 +12 V 0 A 5 A 8 A 12 A 120 mV 2%
3 -5 V 0 A 1 A 1.2 A 1.5 A 50 mV 3%
4 12 V (D) 0 A 3 A 4 A 4.5 A 120 mV 3%
GPC200D GPM200D 1 +5 V 4 A 18 A 26 A 32 A 50 mV 2%
2 +24 V 0 A 3 A 5 A 6.5 A 240 mV 2%
3 -12 V 0 A 1 A 1.2 A 1.5 A 120 mV 3%
4 12 V (D) 0 A 3 A 4 A 4.5 A 120 mV 3%
GPC200E GPM200E 1 +5 V 4 A 18 A 26 A 32 A 50 mV 2%
2 +24 V 0 A 3 A 5 A 6.5 A 240 mV 2%
3 -15 V 0 A 1 A 1.2 A 1.5 A 150 mV 3%
4 15 V (D) 0 A 3 A 4 A 4.5 A 150 mV 3%
GPC200F GPM200F 1 +5 V 4 A 18 A 26 A 32 A 50 mV 2%
2 +12 V 0 A 5 A 8 A 12 A 120 mV 2%
3 -12 V 0 A 1 A 1.2 A 1.5 A 120 mV 3%
4 5 V (D) 0 A 3 A 4 A 4.5 A 50 mV 3%
A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.
B. Ratings for unrestricted natural convection cooling; outputs 1 & 2 combined load not to exceed 22A continuous; total power -150W.
C. Ratings with 26cfm forced air cooling; outputs 1 & 2 combined load not to exceed 32A continuous; total power -200W.
D. Isolated output which may be referenced as a positive or negative voltage.
GPC200/GPM200 MECHANICAL SPECIFICATIONS
Environmental
Operating Non-operating
Specification
o
Tsemperature (A)S5ee individual spec -40 to +8 C
A. Units should be allowed to warm up/operate under non-condensing conditions
HHumidity (A)0Hto 95% R 0 to 95% R
before application of power.
B. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
Sghock (B) 20 40 g
pk pk
orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
Atltitude-t500 to 10,000 f -500 to 40,000 f
C. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 orthogonal axes,
total 6 shocks.
2 2
Vgibration (C) 1.5 , 0.003 g/gHz 5 , 0.026 g /Hz
rms rms