GPFC110 Commercial
110 Watt Global Performance Switchers
110 WATT GLOBAL PERFORMANCE SWITCHERS
FEATURES:
3.1 watts/cu.in. power density
Compact size (6.3 x 3.75 x 1.62;
meets 1U height)
Power factor corrected to IEC 1000-3-2 Class A
Less than 300 A leakage
EMI compliance to CISPR 22, FCC Class B
Approved to UL1950, IEC950 and
CSA 22.2 No. 950
2-year warranty
marked to LVD
RoHS Compliant Model Available (G suffix)
SPECIFICATIONS
Ac Input EMI/EMC Compliance
85-264 Vac, 47-63 Hz single phase. All models include built-in EMI filtering to meet the EMC requirements below.
Input Current
EMI SPECIFICATIONS COMPLIANCE LEVEL
Maximum input current 2.3 A at 90 Vac, 60 Hz with full rated load. Input cur-
Conducted Emissions EN55022 Class B; FCC Class B
rent harmonic content meets the requirements of IEC1000-3-2.
Static Discharge EN61000-4-2, 6 kV contact, 8 kV air
Hold-up Time
RF Field Susceptibility EN61000-4-3, 3 V/meter
25 ms minimum from loss of ac input at full load, nominal line (115 Vac).
Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz
Output Power
Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com.
110 W fan cooled, 75 W convection. Peak ratings are for 60 s maximum dura-
Line Frequency Harmonics EN61000-3-2 Class A
tion, 10% duty cycle.
Inrush Current
Total Regulation
Inrush 240 Vac is less than 37 A, averaged over the first ac half-cycle under cold
Total regulation is the maximum deviation from the nominal voltage for all
start conditions. Limiting provided by internal thermistors.
steady-state loading conditions.
Fan Output
Overload Protection
An additional output, same as Vout, suitable for powering a dc fan is included in all
Fully protected against short circuit and output overload. Short circuit protec-
models. The output is protected by an internal resistor in the event of an overload.
tion is cycling type power limit. Recovery after fault is automatic.
Output Noise
Power Fail
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with
TTL or CMOS compatible output goes low (<0.5 V) 8 ms before output voltage
noise probe directly across output terminals of the power supply.
drops more than 4% below nominal voltage upon loss of ac power. The signal is
factory set to trip when input power can no longer sustain the output.
Transient Response
500 s typical response time for return to within 0.5% of final value for a 50%
Temperature Coefficient
load step change, i/ t< 0.2 A/s. Maximum voltage deviation is 3.5%. Load
0.03%/C typical on all outputs.
must not go below stated minimum.
Environmental
Remote Sense
Designed for 0 to 50C operation at full rated output power; derate output current
Provided as a standard feature. Capable of compensating for 0.25 V total of
and total output power by 2.5% per C above 50C. See Environmental and Pack-
cabling losses in voltage. Open sense lead protection.
aging Specifications on the next page.
Overvoltage Protection
OVP crowbar reduces output voltage below nominal rating in less than 50 ms. Commercial Safety Approvals
All models are approved to UL1950, CSA22.2 No. 950-95, IEC950, EN60950. CB
Voltage Adjustment: Main output 5%.
certificate available. Exceeds FCC and CISPR22 Class B conducted emissions
Input Protection
requirement
Internal ac fuse provided on all models. Fuse does not blow on overload or
short circuitfuse blows only if catastrophic failure occurs in the unit.
O
All specifications are typical at nominal input, full load at 25 C unless otherwise statedCommercial Output Output Output Total
Model Output No. Output Minimum (A) Maximum (A) Maximum (B) Regulation OVP Setpoint Notes
GPFC 110-5 1 5.1 v 0 A 11 A 15 A 2% 6.2 0.6 V C
GPFC 110-12 1 12 V 0 A 6.7 A 9.2 A 2% 14 1.1 V C
GPFC 110-15 1 15 V 0 A 5.3 A 7.3 A 2% 18.5 1.5 V C
GPFC 110-24 1 24 V 0 A 3.4 A 4.6 A 2% 28 2.5 V C
GPFC110-28 1 28 V 0 A 2.9 A 3.9 A 2% 34 2.8 V C
GPFC110-48 1 48 V 0 A 1.7 A 2.3 A 2% 55 4 V C
Notes:
A. With unrestricted convection cooling.
B. With 26cfm airflow.
C. Add G suffix to part number for RoHS compliant model.
GPFC110 MECHANICAL SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING
Temperature (A) See Individual Specs. -40 to +85C A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power.
Humidity (A) 0 to 95% RH 0 to 95% RH
B. Shock testinghalf-sinusoidal, 10 3 ms duration, direction,
Shock (B) 20 g 40 g
3 orthogonal axes, total 6 shocks.
pk pk
C. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to
Altitude -500 to 10,000 ft -500 to 40,000 ft
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and
2 2
Vibration (C) 1.5 g 0.003 g /Hz 5 g 0.026 g /Hz
rms rms 1 hr./axis non-operating.