ME30 20 to 30W Single Output External Power Medical Series Features Meets UL/EN/IEC60601-1-2, 4th edition for * EMC Approved to EN/IEC/UL60601-1, 3rd edition 2 MOPP input-output isolation Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 30W of AC-DC Power Universal Input 90-264Vac Input Range Desktop and Wall-Plug versions Meets EN55011/CISPR11, FCC Part 15.109 Class B Conducted & Radiated Emissions, with >6db margin E-cap life of >8 years >1,000,000 hours MTBF IP22 Rated Enclosure 3 Year Warranty Description A high performance AC to DC external power supply family designed for medical applications. The ME30A Medical Series low power external AC-DC power supplies are approved to safety EN/IEC/UL60601-1, 3rd edition with isolation levels * which satisfy the 2 MOPP requirements and designed to UL/EN/IEC60601-1-2, 4th edition for EMC . The ME30A Series models will operate at universal input range of 90 to 264Vac over the wide temperature range of -20C to +70C, delivering full rated output power up to +40C and applicable output power derating at 70C. These models are available in desktop and wall-plug versions, include an IP22 rating per IEC60529 for the enclosure, and output cable terminated at a variety of output connectors. *Consult Factory for Table 9 compliance information. Model Selection Overvoltage Output Input Model Output Output Ripple & Line Load Number Volts Current Power Noise Regulation Regulation Trip Range Connector Configuration ME30A0503F01 5.0V 4.00A 20W 75mV pk-pk 1% 5% 5.75V-7.75V ME30A0903F01 9.0V 3.00A 27W 90mV pk-pk 11.7V-16.2V 1% 5% 2.5 x 5.5 x Class I ME30A1203F01 12.0V 2.50A 30W 120mV pk-pk 1% 5% 14.4V-16.8V 9.5mm Desktop, ME30A1503F01 15.0V 2.00A 30W 150mV pk-pk 1% 5% 18.0V-21.0V Straight Barrel IEC60320 C14 Type, center ME30A1803F01 18.0V 1.67A 30W 180mV pk-pk 1% 5% 21.6V-25.2V Receptacle positive ME30A2403F01 24.0V 1.33A 30W 240mV pk-pk 28.8V-33.6V 1% 5% ME30A4803F01 48.0V 0.63A 30W 480mV pk-pk 1% 5% 55.0V-60.0V ME30A0503N01 5.0V 4.00A 20W 75mV pk-pk 1% 5% 5.75V-7.75V ME30A0903N01 9.0V 3.00A 27W 90mV pk-pk 1% 5% 11.7V-16.2V 2.5 x 5.5 x Class II ME30A1203N01 12.0V 2.50A 30W 120mV pk-pk 14.4V-16.8V 1% 5% 9.5mm Desktop, ME30A1503N01 15.0V 2.00A 30W 150mV pk-pk 1% 5% 18.0V-21.0V Straight Barrel IEC60320 C8 Type, center ME30A1803N01 18.0V 1.67A 30W 180mV pk-pk 1% 5% 21.6V-25.2V Receptacle positive ME30A2403N01 24.0V 1.33A 30W 240mV pk-pk 28.8V-33.6V 1% 5% ME30A4803N01 48.0V 0.63A 30W 480mV pk-pk 1% 5% 55.0V-60.0V www.slpower.com ME30 Rev 2.1 9-NOV-17 1ME30 20 to 30W Single Output External Power Medical Series Model Selection (continued) Model Output Output Ripple & Line Load Overvoltage Output Input Number Volts Current Power Noise Regulation Regulation Trip Range Connector Configuration ME30A0503Q01 5.0V 4.00A 20W 75mV pk-pk 1% 5% 5.75V-7.75V ME30A0903Q01 9.0V 3.00A 27W 90mV pk-pk 1% 5% 11.7V-16.2V 2.5 x 5.5 x Class II ME30A1203Q01 12.0V 2.50A 30W 120mV pk-pk 14.4V-16.8V 1% 5% 9.5mm Desktop, ME30A1503Q01 15.0V 2.00A 30W 150mV pk-pk 1% 5% 18.0V-21.0V Straight Barrel IEC60320 C18 Type, center ME30A1803Q01 18.0V 1.67A 30W 180mV pk-pk 1% 5% 21.6V-25.2V Receptacle positive ME30A2403Q01 24.0V 1.33A 30W 240mV pk-pk 28.8V-33.6V 1% 5% ME30A4803Q01 48.0V 0.63A 30W 480mV pk-pk 1% 5% 55.0V-60.0V ME30A0503B01 5.0V 4.00A 20W 75mV pk-pk 1% 5% 5.75V-7.75V ME30A0903B01 9.0V 3.00A 27W 90mV pk-pk 1% 5% 11.7V-16.2V Class II Wall- 2.5 x 5.5 x Plug, ME30A1203B01 12.0V 2.50A 30W 120mV pk-pk 14.4V-16.8V 1% 5% 9.5mm Interchangeabl ME30A1503B01 15.0V 2.00A 30W 150mV pk-pk 1% 5% 18.0V-21.0V Straight Barrel e Blades (North Type, center ME30A1803B01 18.0V 1.67A 30W 180mV pk-pk 1% 5% 21.6V-25.2V American Blade positive ME30A2403B01 24.0V 1.33A 30W 240mV pk-pk 1% 5% 28.8V-33.6V included) ME30A4803B01 48.0V 0.63A 30W 480mV pk-pk 55.0V-60.0V 1% 5% ME30A0503C01 5.0V 4.00A 20W 75mV pk-pk 1% 5% 5.75V-7.75V ME30A0903C01 9.0V 3.00A 27W 90mV pk-pk 1% 5% 11.7V-16.2V 2.5 x 5.5 x Class II Wall- ME30A1203C01 12.0V 2.50A 30W 120mV pk-pk 1% 5% 14.4V-16.8V 9.5mm Plug, Fixed ME30A1503C01 15.0V 2.00A 30W 150mV pk-pk 18.0V-21.0V Straight Barrel 1% 5% North American Type, center ME30A1803C01 18.0V 1.67A 30W 180mV pk-pk 1% 5% 21.6V-25.2V Blades positive ME30A2403C01 24.0V 1.33A 30W 240mV pk-pk 1% 5% 28.8V-33.6V ME30A4803C01 48.0V 0.63A 30W 480mV pk-pk 55.0V-60.0V 1% 5% Notes: 1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1F ceramic and 10F low ESR capacitors. For 5V and 6V models, values listed are typical, 100mV pk-pk maximum with 0.1F ceramic and 47F low ESR capacitors used at measurement point. 2. Order blade kit KT-1027K for other blades (EU. UK, Australia) 3. For EU fixed blades, replace C in the model number with M, for UK blades, replace C with G, for Australia blades, replace C with H. 4. All specifications are typical at nominal input, full load, at 25C ambient unless noted. 5. For Input Class I models: For AC GND connected to output common (-), insert a B in the part number where the A is located (ME30B1203F01). General Specifications Parameter Specification Parameter Specification AC Input 100-240Vac, 10%, 47-63Hz, 1 Turn On Time Less than 700mS 115Vac, full load 115Vac: 1.2A, 230Vac:0.6A 20mS min., at full Load, 100Vac input Input Current Hold-up Time Overtemperature Will shutdown upon an overtemperature Inrush Current 264Vac, cold start: will not exceed 40A condition, auto-recovery. Protection F1, F2: 2.0A, 250Vac fuses (line & neutral Input Fuses Overload Protection 130 to 180% of rating, Hiccup Mode lines) provided on all models Earth Leakage Short Circuit <500A 264Vac, 60Hz, NC Hiccup Mode, auto recovery. <1mA 264Vac, 60Hz, SFC Current (Input to Ground) Protection Patient Leakage <100A 264Vac, 60Hz, NC Overvoltage Hiccup mode, see models chart for trip <500 A 264Vac, 60Hz, SFC ranges. Current (Output to Earth) Protection Input-Output: 2 MOPP Efficiency >87%, typical Isolation Input-Ground: 1 MOPP Output-Ground: 1 MOPP 20 to 30W continuous See models chart for Output Power Safety Standards EN/IEC/UL60601-1-1, 3rd edition specific voltage model ratings. No Load Input <0.1W per DoE Efficiency Level VI Operating -20C to +70C. See curve for derating Requirements Power Temperature See models chart on pg 1. -40C to +85C Ripple and Noise Storage Temperature Operating: to 5000m. Output Voltage See models chart on pg 1. Altitude Non-operating: -500 to 40,000 ft. 500 s response time for return to within 0.5% Transient of final value for any 50% load step over the Relative Humidity 5% to 95%, non-condensing range of 5% to 100% of rated load, i/ t< Response 0.2A/ s. Max. voltage deviation is +/-3.5%. 1.4m from table top to wooden platform, 6 Regulation See models chart on pg 1. Drop Test faces. www.slpower.com ME30 Rev 2.1 9-NOV-17 2