MINT1500 Single Output 500 Watts Medical Power Supply 3.3 x 7 x 1.5 Pack age, fits 1U app lication Up to 500W of AC-DC Power Universal Input 85-264 Vac Class I Input Standby and Fan output voltages Active Current Share Inhibit, Power Fail, Output OK signals rd Approved to IEC60601-1 3 with 2 MOPP Isolation & nd EN60950-1 2 Edition Efficiency 92% Low line & 94% for High Line Optional Cover PRELIMINAEY Optional Fan with 2 orientations Description A superior performance 500 Watt AC to DC power supply designed for Medical or industrial applications. Feature rich and highly efficient, MINT1500 product family with active current share for redundant applications can easily fit in 1U or 2U chassis and provides 350 Watts (275W on 12V) without cover for convection, or 500 Watts with moving air. Input & output monitoring alarms plus 12V/1A fan output and 5V standby voltage are standard features of the MINT1500 family. rd nd All models are CE marked to low voltage directive and approved to IEC60601-1 3 edition, EN60950 2 edition. Model Number Key MINT 1 500 X 12 14 E 0101 = Standard. 02 and higher indicates a modified model. Model Input Connector:Input Connector: = 3 Pin, L= terminal block, I = IEC, others Output Connector: available Screw Type Output Voltage:12 = 12Vdc,24 = 24Vdc, 48 = 48Vdc Model = U Chassis Only, C=with Cover, , T=top fan Option, E= end fan option Output Power: 500 = 500 Watts of Outputs1 = Single Output Product Family : = Medical, = Internal,N = New Output Parameters Model Output Current Total Max. Ripple & Noise (2) OVP Number (4) Volts (V) w/airflow (1) Convection Regulation (mV) Threshold MINT1500A1214E01 12 V 41.6 A 22.9 A 2% 160 13.8 0.5V MINT1500A2414E01 24 V 20.8 A 14.6 A 2% 240 27.6 1.0V MINT1500A4814E01 48 V 10.4 A 7.3 A 2% 240 55.2 2.0V MINT1500A5614E01 56 V 8.9 A 6.3 A 2% 240 64.3 2.0V Notes: 1. 200 LFM forced air cooling required for non-convection ratings 2. Measured with noise probe directly across output terminals, and load terminated with 0.1F ceramic and 10F low ESR capacitors. 3. Consult factory for other voltages 1 of 6 SL Power Electronics Corp 6050 King Drive Ventura, CA 93003 Phone 805.486.4565 Fax 805.832.6131 Email: info slpower.com www.slpower.com 5-29-12 MINT1500 Single Output 500 Watts Medical Power Supply Specifications All Specifications are typical at nominal input, full load at 25C unless otherwise stated AC Input 85-264 Vac 47-63 Hz single phase Turn On Time Less than 500 ms 115Vac 120 300 Vdc (External fuse required when DC input is applied) Input Current Typical 115Vac: 5A, Hold-up Time 16 ms at 500 W with 230Vac:2.5A output voltage drop out to 90% Inrush Current 264 Vac, cold start: will not exceed 10A Over Temperature Protection Sensing transformer and heatsink temperature, Self recovering Input Fuses F1, F2: 10A, 250VAC Overload Protection 120 to 140% of current rating, Cycling type Earth Leakage Current <275A 264Vac, 60Hz, NC <400A Short Circuit Protection Self recovering SFC xx value Isolation Input-Output: 4000Vac Switching Frequency Variable Input-Ground: 1800Vac, Output-Ground: 700Vdc PFC converter: 50-500 kHz LLC converter: 80-220 kHz Efficiency 92% typical Overvoltage Protection OVP latch Type See Table Power Factor Correction minimum of 90% Operating Temperature -10 to +70C derate by 2.5%/C for ambient greater than 50C Output Power 500W continuous Vibration Operating: 0.003g2/Hz, 1.5grms overall, 3 axes, 10 With 200 LFM and up to 350 Watts for Convection Cooled, min/axis Non-Operating: 0.026 g2/Hz, 5.0grms overall, 3 axes, 100VAC, 50C Ambient . 275 Watts on 12V unit without cover 1 hr/axis Transient Response 500s typ. for return to within 0.5% of Storage Temperature -40 to +85C nominal, 50% load step. i/t <0.2A/S. Max Volt Deviation = 3% Ripple and Noise See chart Operating Altitude up to 3000 meters Output Voltage See chart Non-operating Altitude -152 to 12,192 meters Voltage Adjustability +/-5% from nominal R e l a tive Humidity 5% to 95%, non-condensing Minimum Load Not required Dimensions W: 3.3( 83.8mm), L: 7.0(177.8mm), H.1.5 (38.1mm) Standby Voltage 5V / 200 mA with +/-5%regulation Weight 0.6Kg and 0.7Kg with cover option Current Share Active Single wire for up to 5 supplies Fan Output 12V/1A with +/-10% regulation with 0.1A or more on main output EMI/EMC Compliance Conducted Emissions EN55011/22 Class B, FCC Part 15, Class B, 6 dB margin Radiated Emissions EN55011/22 Class A, FCC Part 15, Class A, 6 dB margin Static Discharge Immunity EN61000-4-2, 6kV Contact Discharge, 8kV air discharge Radiated RF Immunity EN61000-4-3, 3V/m. EFT/Burst Immunity EN61000-4-4, 2kV/5kHz Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode Conducted RF Immunity EN61000-4-6, 3Vrms Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m Voltage Dip Immunity EN61000-4-11, 100%, 10ms 30%, 500ms (80% load) 60%, 100ms (60% load) 100%, 5000ms Performance Criteria A A A B. Line Harmonic Emissions EN61000-3-2, Class A, C & D 2 of 6 SL Power Electronics Corp 6050 King Drive Ventura, CA 93003 Phone 805.486.4565 Fax 805.832.6131 Email: info slpower.com www.slpower.com 5-29-12