Uninterruptible Power Supplies SDU AC -A Series, DIN Rail UPS The SolaHD SDU AC - A Series DIN Rail UPS combines an industry leading compact design with a wide operation temperature range, enhanced communication and unique installation options. The SDU Series provides economical protection from damaging impulses and power interruptions. These units include easy to wire screw terminations for critical devices needing battery back up such as computer based control systems. Applications Programmable Logic Controllers Factory Automation E179213 Robotics E491259 Conveying Equipment Computer based Control Systems UL Recognized Component, UPS Equipment, UL 60950 E1729213 E137632 Features CUL/CSA-C22.2 No. 234-M90 - UL 1778 5th Ed., CSA C22.2 No. 107.3 Lightweight, compact industrial design - Suitable for UL 508 at full load output (no derating) and Communications port for optional Industrial Ethernet Ind. Control Equipment Applications Overvoltage Cat III, protocols or discrete communication card Pollution Degree III Wide operation temperature range (0 C to 50 C) UL Recognized Component, Hazardous UL 60950 Cold start capability Locations E491259 E137632 CUL/CSA-C22.2 No. 234-M90 Software and cable included for easy installation - ANSI ISA 12.12.01/CSA 213 Simulated sinewave output - Class I, Division 2, Groups A, B, C, D, T3 USB communication port ODVA Compliant Remote turn-on and shutdown capabilities - EtherNet/IP SDUENETIPCARD has been tested and approved for conformance by the ODVA. More Two year limited warranty information about EtherNet/IP and the ODVA can be Panel/wall mounting brackets (optional) obtained from the following website: www.odva.org. RoHS Compliant Certifications and Compliances Related Products Portable MCR Power Conditioners - Low Voltage Directive: EN62040-1 STV Surge Protective Devices - EMC Directive: EN62040-2 SDN DIN Rail Power Supplies STFV Plus Active Tracking Filters Selection Table Catalog Capacity Volts, Frequency Typical Back-Up Time (minutes) Input/Output Approx. Ship Number (VA/W) In/Out At full load/half load. Connections Weight - lbs (kg) 500/300 4/18 10.6 (4.8) SDU 500A 120 Vac, 50/60 Hz IP20 touch proof, screw 850/510 2/10 11.5 (5.2) SDU 850A terminals. 500/300 4/18 10.6 (4.8) SDU 500A-5 Wire range: 10 ~ 18 AWG. 230 Vac, 50/60 Hz 850/510 2/10 11.5 (5.2) SDU 850A-5 Note: Run times in this table are approximate. They are based upon new, fully charged standard battery modules at a temperature of 25C (77F) with 100% resistive UPS loading. Run times listed above can vary by +/-5% due to manufacturing variances of the individual batteries Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. 65 December 2018Uninterruptible Power Supplies Specifications Catalog Number SDU 500A SDU 850A SDU 500A-5 SDU 850A-5 500/300 850/510 500/300 850/510 Capacity (VA/Watts) 0.6 Load Power Factor Dimensions - inches (mm) 4.87 x 11.1 x 4.81 (123.7 x 281.9 x 122.3) Unit (H x W x D) - in. (mm) 10.6 (4.8) 11.5 (5.2) 10.6 (4.8) 11.5 (5.2) Weight - lbs (kg) Input Parameters 120 V (+10%, -20%) 230 V (+/- 15%) Voltage 50 +/- 5 Hz or 60 Hz +/- 6 Hz (auto sensing) Frequency Output AC Parameters Simulated sinewave Voltage (Battery Mode) +/- 5% 50 or 60 Hz +/- 0.3 Hz Frequency (On Battery) UPS automatic shutdown if overload exceeds: 105% of nominal at 20 seconds, Overload Protection 120% of nominal at 10 seconds, 130% of nominal at 3 seconds UPS shutdown, auto-recovery Short Circuit Battery Parameters Sealed, non-spillable, maintenance-free lead acid batteries Battery Type Typical <8 ms Transfer Time Back-Up Time (minutes) 4/18 2/10 4/18 2/10 Full Load/Half Load 8 hours to 90% capacity of full discharge Recharge Time Environmental 0C to 50C Operating Temperature -15C to 60C Storage Temperature 0 to 95%, non-condensing Relative Humidity 0-95% humidity non-condensing, 0-50C up to 6,600 ft. (2000m) Ambient Operation < 40 dBA (1 meter from surface) Audible Noise Standards FCC Part 15, Subpart B, Class A Level 4 EMC: EN62040-2 EN55032 CISPR22 EMC EN61000-3-2 IEC61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -2-2 5000 ft. without derating Elevation Meets IEEE C62.41, Category A Surge Protection Operating - IEC60068-2-27, Half Sine Wave: 10G for a duration of 11ms, shock for 1 direction (X axis) Shock Non-operating - IEC60068-2-27, Half Sine Wave : 30G for duration of 11ms, 3 shocks for all 3 axes Operating - IEC60068-2-6, Sine Wave: 10Hz to 500Hz 19.6m/S, displacement of 0.35mm, 60 min per axis for all X, Y, Z direction. Vibration Non-operating - IEC60068-2-6, Random : 5hz to 500Hz (2.09Grms) 20 min per axis for all X,Y,Z To be mounted on DIN TS35/7.5 or TS35/15 rail system. Chassis mounting permissible via optional brackets (SDU-PMBRK). Mounting Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. 66 December 2018