Power Supplies
3
SHP Series: Heavy Duty Modular Power Supplies
This new generation of high power, intelligent modular power
supplies, range from 1500 through 4920 watts and were
designed for optimum flexibility. The modular design makes
these units easy to customize for unusual voltage and power
combinations, and the intelligent modules allow the use
2
of I C or CANBUS/RS485 communication to monitor and
control many attributes of the power supply.
All units have power factor corrected inputs, an end
mounted fan for cooling and a variety of built-in signals and
controls. High reliability and a flexible design make these
power supplies an excellent choice for process control and
semiconductor fabrication applications.
E137632
Applications
Process Controls
Related Products
Semi-Conductor Fabrication
Automated Service Equipment
Surge Protective Devices
SCD DC to DC Converters
Active Tracking Filters
Features
Available in intelligent and non-intelligent models
Single, dual and triple output modules configurable in
combinations up to 24 different outputs
Standard Offering Selection Table
Single phase and three phase inputs
Catalog Number Output Voltage Output Current Watts
2
I C control in intelligent modules
SH30-4LS-0Z 12 V 125 A 1500
End mounted intelligent fan (speed control/fault status)
SH30-4NS-0Z 15 V 100 A 1500
2
Voltage adjustment on all outputs (manual or I C)
SH30-4QS-0Z 24 V 62 A 1500
CANBUS and RS-485 optional interface
SH30-4RS-0Z 28 V 53 A 1500
Overload protection on all outputs
SH30-4WS-0Z 48 V 31 A 1500
Power factor correction (.99 typ.)
SH45-4QS-3QS-4Z 24 V 92 A 2000
Configurable output UP/DOWN sequencing
Modular Construction
Configurable input and output OK signals and indicators
Programmable voltage, current limit, inhibit/enable
Accessories Table
2
through I C
Catalog Number Description
Three year limited warranty
2
73-769-001 USB to I C adapter
70-841-004 Mating Connector Kit for Control & Signals (J1 Connector)
2
70-841-023 Mating Connector Kit for I C Interface (J2 Connector)
Certifications and Compliances
Note: Connector kit includes connector housing and 10 terminals.
UL Recognized Component, ITE, E137632
UL 60950
E137632
-CUL/CSA-C22.2 UL 60950-1/CSA C22.2 No. 60950-1, 2nd Edition
No. 234-M90
- Low Voltage Directive
- IEC/EN 60950-1, 2nd Edition
Contact Technical Services at (800) 377-4384 with any questions.
168
Visit our website at www.solahd.com. Power Supplies
3
Specifications
Description SH30 SH45 S3H3 S3H5
Input
90264 Vac; 120300 Vdc; Single-phase 170-264 Vac; Three-phase
Input voltage range
4763 Hz
Frequency
40 A peak maximum (soft start)
Inrush current
Up to 85% at full load
Efficiency
0.99 typical
Power factor
2
AC on 1.5 s typical, inhibit/enable 150 ms typical, configurable through I C; 50 ms internal turn-on delay (dual output only)
Turn-on time
10 ms minimum
Hold-up time
2
>5 ms early warning before outputs lose regulation, full cycle ride through at 50 Hz, configurable through I C
AC OK
Output
2
10% minimum for all outputs, user-adjustable pot, full adjustment range using I C
Output voltage range
Factory set point accuracy 0.01
2
5%
I C output program accuracy
46% nominal analog (single output module only)
Margining
0.4% or 20 mV maximum (1% maximum for 1500 W module)
Line/load regulation
Ripple RMS: 0.1% or 10 mV maximum; Pk-Pk: 1.0% or 50 mV maximum; bandwidth limited to 20 MHz
Dynamic response <2% or 100 mv with 25% load step
Within 1% in <300 s
Recovery time
Single output module and main output of the dual output module 105120% of rated output current. Aux output of dual output module
Overcurrent protection 105140% of rated output current. Special programmable OCP delay on 1500 W module from 100 ms to 25.5 s with shutdown features.
2
Configurable through I C with load calibration required (except for 1500 W module).
Short-circuit protection Protected for continuous short-circuit; recovery is automatic upon removal of short. Shutdown mode available on the 1500 W module.
Single output module: 25.5 V, 122134%; 660 V, 110120%; Dual output module: 26 V, 122134%; 828 V, 110120%
Overvoltage protection
2
Triple output module: No overvoltage protection provided; Configurable through I C
2
Thermal protection All outputs are disabled when the internal temperature exceeds the safe operating range; configurable through I C
Up to 0.5 V drop (not available on triple output module)
Remote sense
Single wire parallel Current share to within 2% of total rated current
2
DC OK 5% of nominal; configurable through I C
Not required
Minimum load
Housekeeping bias voltage 5 V dc @ 1.0 A maximum present whenever ac input is applied
2
Module inhibit Configured and controlled through I C
Output/output isolation >1 M, 500 V
2
TTL, Logic 1 and Logic 0; configurable through I C
Global inhibit/enable
Environmental
Operating temperature -40 C to +70 C ambient; derate each output 2.5% per degree from 50 C to 70 C
-40 C to +85 C
Storage temperature
10% to 95% RH, non-condensing
Humidity
IEC68-2-6 to the levels of IEC721-3-2
Vibration
>550,000 hr. @ full load, 220 V ac, 25 C ambient
MTBF demonstrated
Safety
EN61000-4-2, EN61000-4-4, EN61000-4-5 Level 3
Electromagnetic susceptibility
CISPR 22/EN55022 Level B when installed in a properly grounded and shielded metal enclosure
EMI filter
CISPR 22/EN55022 Level B when installed in a properly grounded and shielded metal enclosure
Radiated EMI
General
5 x 5 x 11 5 x 8 x 11 5 x 5 x 11 5 x 8 x 11
Case dimensions
(127.0 x 127.0 x 279.4) (127.0 x 203.2 x 279.4) (127.0 x 127.0 x 279.4) (127.0 x 203.2 x 279.4)
H x W x D in (mm)
6.2 lbs (2.81 kg) 9.0 lbs (4.08 kg) 6.2 lbs (2.81 kg) 9.0 lbs (4.08 kg)
Case weight
9 14 9 14
Slots available per case
3 years
Limited warranty
Contact Technical Services at (800) 377-4384 with any questions.
169
Visit our website at www.solahd.com.