Uninterruptible Power Systems
3
S4K2U-C and S4K2U-5C Industrial On-Line UPS
The new SolaHD S4KC is a single-phase, on-line (double-
conversion) UPS system available in 500-3000VA, 120V and
230V. On-Line design means zero transfer time from external
to internal power. When utility power fails, your critical load
remains supported by a seamless flow of power. Rack or
tower configurable, the SolaHD S4KC UPS offers customers
a higher power factor, longer battery life, higher reliability and
reduced cost of ownership. Housed in a slim 2U package,
the SolaHD S4KC protects equipment from virtually all power
disturbances due to blackouts, brownouts, sags, surges or
noise interference. The UPS includes internal batteries.
Optional, matching external battery cabinets, also in a slim
2U (3.5") size, offer extended battery runtime.
The LED display indicates battery capacity, percentage of
UPS load, battery operation, bypass operation and UPS
E179213
fault condition.
Applications
The rack-tower models are also supplied with securing
flanges and rack slide mounting hardware. Units can be
Industrial Automation Systems
easily hardwired by removing the attached line cord and
Critical Microprocessors and PC Based Systems
receptacle plate. All units include a conduit knockout cover
Robotics and Process Control
in the box.
Programmable Logic Controllers (PLC)
Mission Critical and High Speed Networks
Features
Enterprise Telecommunication Systems
Hardwire capability for permanent installation
Pharmaceutical and Medical Diagnosis Equipment
Small 2U height maximizes available space
Printing and Publishing Machinery
Input and output noise suppression
Higher Output Power Factor of 0.90
PWM inverter reduces output voltage distortion
Add on batteries for extended back-ups
Integral sealed non-spillable batteries
Hot swappable user replaceable battery
Automatic restart
Automatic and manual battery test
Rack-mount or Stand-alone tower mounting
Units are field configurable with a PC as a frequency
converter (bypass will be disabled)
Integral dynamic bypass reduces shutdowns
Compatible with most standby generators
Two-year limited warranty
Note:
The securing flanges do not support the weight of the UPS. Rack slides or shelves are
required (sold separately).
Visit our website at www.solahd.com or
contact Technical Services at (800) 377-4384 with any questions.
68Uninterruptible Power Systems
3
Selection Table - S4K2U-C & S4K2U-5C Tower/Rack-Mount Models
Capacity Catalog Typical Back-up Times Input Plug/Output Approx. Ship
(VA/W) Number (minutes)* Receptacle Weight - lbs (kg)
120 Vac, 50/60 Hz Models
700/630 6/14 5-15P / (6) 5-15R
S4K2U700-C
52.9 (24)
1000/900 5/15 5-15P / (6) 5-15R
S4K2U1000-C
1500/1350 5/16 5-15P / (6) 5-15R 57.3 (26)
S4K2U1500-C
2000/1800 4/11 5-20P / (6)5-20R (15/20 amp type) 61.7 (28)
S4K2U2000-C
3000/2700 4/14 L5-30P / (5)5-20R (15/20 amp type): (1) L5-30R 70.5 (32)
S4K2U3000-C
230 Vac, 50/60 Hz International Models
1000/900 5/15 IEC 320-C14 / (6) IEC 320/C13 44.0 (20)
S4K2U1000-5C
2000/1800 4/11 IEC 320-C20 / (6) IEC 320-C13 61.7 (28)
S4K2U2000-5C
3000/2700 4/14 IEC 320-C20 / (6) IEC 320-C13 (1) IEC 320-C19 70.5 (32)
S4K2U3000-5C
* Full/Half Load (in minutes).
Visit our website at www.solahd.com or
contact Technical Services at (800) 377-4384 with any questions.
69