DENSEI-LAMBDA DLP75-24-1 SPECIFICATIONS CA733-01-01A This specifications sheet also apply to option model /E,/EJ MODE ITEMS DLP75-24-1 1 Nominal Output Voltage V 24 2 Maximum Output Current A 3.1 3 Maximum Output Power W 74.4 4 Efficiency (100/230VAC) (Typ) ( * 1 ) % 82/83 5 Input Voltage Range ( * 2 ) 85~132/170~265VAC (Auto selectable) / 47~63Hz 6 Input Current (100/230VAC) (Typ) ( * 1 ) A 1.7/0.8 o 7 Inrush Current (100/230VAC) (Typ) ( * 3 ) 20A at 100VAC, 45A at 230VAC, Ta=25 C, Cold Start 8 PFHC Built to meet IEC61000-3-2 9 Output Voltage Range V 21.6~28 Maximum Ripple & Noise 0Ta60C mV 240 10 ( * 4 ) -10 Ta<0C mV 360 11 Maximum Line Regulation ( * 4, 5 ) mV 120 12 Maximum Load Regulation ( * 4, 6 ) mV 192 13 Temperature Coefficient Less than 0.05%/C 14 Over Current Protection ( * 7 ) A 3.3~ 15 Over Voltage Protection ( * 8 ) V 30.0~35.0 16 Hold-Up Time (100/230VAC) ( * 1 ) 20ms /30ms 17 Leakage current ( * 9 ) Less than 0.75mA 18 Parallel Operation - 19 Series Operation Possible - 10 ~ + 60 C 20 Operating Temperature ( * 10 ) Convection: -10 ~ +50C ( 100% ) 60C ( 60% ) 21 Operating Humidity 30 ~ 90 %RH (No dewdrop) 22 Storage Temperature - 30 ~ +85C 10 ~ 95%RH (No dewdrop) 23 Storage Humidity 24 Cooling Convection cooling Input - Output : 3.0kVAC, Input - FG : 2.0kVAC (20mA) for 1min 25 Withstand Voltage Output - FG : 500VAC (100mA) for 1min. More than 100M at Ta=25C and 70%RH, Output - FG : 500VDC 26 Isolation Resistance At no operating and with DIN RAIL, 27 Vibration 2 10~55Hz (Sweep for 1min) 9.8m/s Constant, X, Y, Z each 1hour 2 28 Less than 196m/s Shock (In package) Approved by UL60950, CSA60950, EN60950, UL508, CSA C22.2 No.14, 29 Safety EN50178 CATEGORY III(Primary). Built to meet DENAN. Class 2 power supply approved by UL508&NFPA725.41 Built to meet VCCI-B, FCC-ClassB, EN55011/EN55022-B 30 EMI 31 Immunity Built to meet IEC61000-6-2 (IEC61000-4-2,-3,-4,-5,-6,-8,-11) 32 Weight (Typ) g 470 33 mm 50x97x110 (Refer to Outline Drawing) Size ( W.H.D.) * Read instruction manual carefully , before using the power supply unit. Output terminal = NOTES= Rail * 1: At 100/230VAC and maximum output power, Ta = 25C. * 2 : For cases where conformance to various safety specs ( UL, CSA, EN ) are required, to be described as 100-120VAC/200-240VAC, 50 / 60Hz on name plate. Fig. B * 3 : Not applicable for the in-rush current to Noise Filter for less than 0.2ms. * 4 : Please refer to Fig A for measurement of line & load regulation and output ripple voltage. (Measure with JEITA RC-9131 probe) Input terminal L * 5 : 85-132VAC/170-265VAC, constant load. * 6 : No load - Full load(Maximum power), constant input voltage. +V * 7 : Foldback type O.C.P with automatic recovery. A Output Avoid to operate at overload or dead short for more than 30seconds. terminal C2 + C1 * 8 : OVP circuit will shutdown output, manual reset. (Re Power on) * 9 : Measured by each measuring method of UL, CSA, EN and -V DENAN (at 60Hz). L : 150mm *10: At standard mounting method, Fig B. C1 : Elec. Cap 100uF C2 : Film Cap 0.1uF Measurement point - Load(%) is percent of maximum output load ( Item2 and 3 ), do Measurement point for Bandwidth of scope : 100MHz for Vripple Vo Line/Load Regulation. not exceed derating in both Maximum Output Current and Power. -For standard mounting, refer to derating curve (CA733-01-02 ) Fig. ADENSEI-LAMBDA DLP75-24-1 OUTPUT DERATING CA733-01-02 (This specifications sheet also apply to option model /E,/EJ) DLP75-24-1 *COOLING: CONVECTION COOLING LOADING CONDITION(%) Standard Mounting Ta(C) -10~50 100 60 60 OUTPUT DERATING CURVE 100 80 60 40 20 0 -10 0 1020 3040 5060 Ta (C) Output connector Rail Input connector STANDARD MOUNTING LOAD (%)